Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Standard Curve/Testing Data

OxiSelect UV-Induced DNA Damage (CPD Quantitation) ELISA Kit

OxiSelect UV-Induced DNA Damage ELISA Kit (CPD Quantitation)

Synonyms
OxiSelect UV-Induced DNA Damage (CPD Quantitation); OxiSelect UV-Induced DNA Damage ELISA Kit (CPD Quantitation); OxiSelect UV-Induced DNA Damage (CPD Quantitation) elisa kit
Ordering
For Research Use Only!
Preparation and Storage
Upon receipt, Store the CPD-DNA standard at -20 degree C and all other components at 4 degree C until their expiration dates.

Typical Standard Curve/Testing Data

Typical Standard Curve/Testing Data
Related Product Information for OxiSelect UV-Induced DNA Damage (CPD Quantitation) elisa kit
Principle of the Assay: CDP-DNA standards or unknown DNA samples are first heat denatured before being adsorbed onto a 96-well DNA high-binding plate. The CPDs present in the sample or standard are probed with an anti-CPD antibody, followed by an HRP conjugated secondary antibody. The CPD content in an unknown sample is determined by comparing with a standard curve that is prepared from predetermined CPD-DNA standards.

Background/Introduction: Absorption of ultraviolet (UV) light produces two predominant types of DNA damage, cyclobutane pyrimidine dimers (CPD) and pyrimidine (6-4) pyrimidone photoproducts (6-4PP) (Figure 1). The result is a transition of C to T and CC to TT, which are the most frequent mutations of p53 in both human and mouse skin cancers. UV damaged DNA is usually repaired by nucleotide excision repair (NER) or base excision repair (BER). After UV exposure, cells activate p53 and stall the cell cycle for repair. If the damage is too severe, the cell will trigger apoptosis to get rid of DNA damaged, potentially mutant cells. OxiSelect Oxidative UV-induced DNA Damage ELISA Kit (CPD Quantitation) is an enzyme immunoassay developed for rapid detection and quantitation of CPD in any DNA samples. The quantity of CPD in unknown sample is determined by comparing its absorbance with that of a known CPD-DNA standard curve. Each kit provides sufficient reagents to perform up to 96 assays, including standard curve and unknown samples.
Product Categories/Family for OxiSelect UV-Induced DNA Damage (CPD Quantitation) elisa kit
References
1. Lippke JA, Gordon LK, Brash DE, Haseltine WA. (1981) Proc Natl Acad Sci U S A. 78:3388-3392
2. Mitchell DL, Nairn RS. (1989) Photochem Photobiol. 49:805-819.
3. Ananthaswamy HN, Loughlin SM, Cox P, Evans RL, Ullrich SE, Kripke ML. (1997) Nat Med. 3:510-514.
4. Soehnge H, Ouhtit A, Ananthaswamy ON. (1997) Front Biosci. 2:D538-D551.
5. el-Deiry WS, Tokino T, Velculescu VE, Levy DB, Parsons R, Trent JM, Lin D, Mercer WE, Kinzler KW, Vogelstein B. (1993) Cell. 75:817-825.
6. Hermeking H, Lengauer C, Polyak K, He TC, Zhang L, Thiagalingam S, Kinzler KW, Vogelstein B. (1997) Mol Cell. 1:3-11.
7. Hill LL, Ouhtit A, Loughlin SM, Kripke ML, Ananthaswamy HN, Owen-Schaub LB. (1999) Science. 285:898-900.
1. Rimann, M. et al. (2015). Standardized 3D bioprinting of soft tissue models with human primary cells. J Lab Autom. doi:10.1177/2211068214567146.
2. Donninger, H. et al. (2015). The RASSF1A tumor suppressor regulates XPA-mediated DNA repair. Mol Cell Biol. 35:277-287.
3. Zirkin, S. et al. (2013). The PIM-2 Kinase is an essential component of the ultraviolet damage response that acts upstream to E2F-1 and ATM. J. Biol. Chem. 288:21770-21789.
4. Burgess, H.M. et al. (2011). Nuclear relocalisation of cytoplasmic poly(A)-binding proteins PABP1 and PABP4 in response to UV irradiation reveals mRNA-dependent export of metazoan PABPs. J. Cell Sci. 124: 3344-3355.

Similar Products

Product Notes

The OxiSelect UV-Induced DNA Damage (CPD Quantitation) (Catalog #AAA168006) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "OxiSelect UV-Induced DNA Damage (CPD Quantitation), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.