CD97 ELISA Pair Set | ADGRE5 elisa pair set

CD97 Matched ELISA Antibody Pair Set, Human

Synonyms
CD97; CD97 Matched ELISA Antibody Pair Set; Human; Human CD97 ELISA Pair Set; adhesion G protein-coupled receptor E5; TM7LN1 Matched ELISA Antibody Pair Set; ADGRE5 elisa pair set
Ordering
For Research Use Only!
Specificity
Quantitative determination of Human CD97
Assay Type
Solid Phase Sandwich ELISA
Detection Range
31.25-2000pg/mL
Sensitivity
31.25pg/ml
Materials Provided
1. Capture Antibody 0.5 mg/mL of mouse anti-CD97 monoclonal antibody. Dilute to a working concentration of 2.0ug/mL in CBS before coating.
2. Detection Antibody 0.5 mg/mL mouse anti-CD97 monoclonal antibody conjugated to horseradish-peroxidase (HRP). Dilute to working concentration of 1.0ug/mL in detection antibody dilution buffer before use.
3. Standard Each vial contains 80 ng of recombinant CD97. Reconstitute with 1 mL detection antibody dilution buffer. After reconstitution, store at -20 degree C to -80 degree C in a manual defrost freezer. A seven-point standard curve using 2-fold serial dilutions in sample dilution buffer, and a high standard of 2000 pg/mL is recommended.
Preparation and Storage
Capture Antibody: Aliquot and store at -20 degree C to -80 degree C for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles.
Detection Antibody: Protect it from prolonged exposure to light. Aliquot and store at -20 degree C to -80 degree C and for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles.
Standard: Store lyophilized standard at -20 degree C to -80 degree C for up to 6 months from date of receipt. Aliquot and store the reconstituted Standard at -80 degree C for up to 1 month. Avoid repeated freeze-thaw cycles.

Testing Data

Testing Data
Related Product Information for ADGRE5 elisa pair set
The cluster of differentiation (CD) system is commonly used as cell markers in immunophenotyping. Different kinds of cells in the immune system can be identified through the surface CD molecules which associating with the immune function of the cell. There are more than 32 CD unique clusters and subclusters have been identified. Some of the CD molecules serve as receptors or ligands important to the cell through initiating a signal cascade which then alter the behavior of the cell. Some CD proteins do not take part in cell signal process but have other functions such as cell adhesion. The CD97 is a receptor predominantly expressed in leukocytes and belongs to a new group of seven-span transmembrane molecules, which is also designed EGF-TM7 family. The family members are characterized by an extended extracellular region with several N-terminal epidermal growth factor-like domains two of which contain a calcium-binding site. Mature CD 97 has two noncovalently associated subunits and is composed of a large extracellular protein (CD97 alpha) and a seven-membrane spanning protein (CD97 beta). CD97 is considered as a defining feature of G protein-coupled receptors. The effects that lymphocytes and erythrocytes adhere to CD97-transfected COS cells suggest that CD97 has the ability to bind cellular ligands. CD97 alpha has three alternatively spliced isoforms that are related to the calcium-binding EGF-like repeats in the microfibril protein fibrillin. Leukocytes strongly positive for CD97 are concentrated at sites of inflammation relative to CD97 expression in normal lymphoid tissues.

This CD97 Matched ELISA Antibody Pair Set, Human is a solid phase sandwich ELISA for quantitative determination of Human CD97. It contains Human CD97 capture antibody, Human CD97 detector antibody (HRP) and a highly purified HEK293-expressed recombinant Human CD97 protein.
References
Ho IC, et al. (2009) GATA3 and the T-cell lineage: essential functions before and after T-helper-2-cell differentiation. Nat Rev Immunol. 9 (2): 125-35.Matesanz-Isabel J, et al. (2011) New B-cell CD molecules. Immunology Letters.134 (2): 104-12.Gray JX, et al. (1996) CD97 is a processed, seven-transmembrane, heterodimeric receptor associated with inflammation. The journal of Immunology. 157 (12): 5438-47.Hamann J, et al. (1998) Characterization of the CD55 (DAF)-binding site on the seven-span transmembrane receptor CD97.European Journal of Immunology. 28 (5): 1701-7.

Similar Products

Product Notes

The ADGRE5 (Catalog #AAA8118370) is an ELISA Pair Set and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "CD97, ELISA Pair Set" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.