Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Mouse anti-Human VCAM-1 Monoclonal Antibody | anti-VCAM-1 antibody

VCAM-1, Human, mAb 1G11B1, biotinylated

Gene Names
Vcam1; VCAM1B
Reactivity
Human
Applications
Flow Cytometry, Functional Assay, Immunohistochemistry, Immunofluorescence
Synonyms
VCAM-1; Monoclonal Antibody; Human; mAb 1G11B1; biotinylated; CD106; INCAM-100; L1CAM; MGC99561; DKFZp779G2333;; VCAM-1 Human mAb 1G11B1 Biotin 50ug; anti-VCAM-1 antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human
Clonality
Monoclonal
Isotype
IgG1
Form/Format
0.5ml (100ug/ml) 0.2um filtered biotinylated antibody solution in PBS, containing 0.02% sodium azide and 0.1% bovine serum albumin.
Sequence Length
739
Applicable Applications for anti-VCAM-1 antibody
Flow Cytometry (FC/FACS), Immunohistochemistry (IHC) Frozen, Functional Studies (FS), Immunoassay (IA), Immunofluorescence (IF)
Application Notes
The typical starting working dilution is 1:50.
IHC-F: Cryostatic sections were fixed in acetone, and incubated with mAb at 10ug/ml in PBS/0.1% tween20
FC: 1ug mAb per 1x105 cells
FS: Stimulated EC were preincubated for 30' at 37 degree C with mAb and than used in adhesion assay with T-cells
IP: precleared EC lysates were immunoprecipitated with mAB and analyzed by 7.5% SDS-PAGE under reducing conditions
Immunogen
Full length protein
Conjugation
Biotin
Positive Control
Activated endothelial cells
Preparation and Storage
Product should be stored at 4 degree C.
Under recommended storage conditions, product is stable for at least one year. The exact expiry date is indicated on the label.
Related Product Information for anti-VCAM-1 antibody
The monoclonal antibody 1G11B1 recognizes vascular cell adhesion molecule-1 (VCAM-1). VCAM-1 is a member of the immunoglobulin superfamily of adhesion molecules, which includes ICAMs, PECAM-s and MADCAM, and is involved in leukocyte-endothelial cell interactions. The immunoglobulin superfamily is a type I transmembrane protein characterized by extracellular immunoglobin domains, a transmembrane region and a cytoplasmic tail. They are essential for the development of the embryo and for immune and inflammatory responses. These transmembrane glycoproteins mediate cell interaction with, and adhesion to, other cells and the extracellular matrix. VCAM-1 contains six immunoglobulin domains of the H-type and interacts with VLA-4 expressed on leukocytes. Multiple adhesion molecules play a role in leukocyte recruitment. The process of migration of a leukocyte through the vascular endothelium consists of the following steps: leukocyte-endothelium interaction (first tethering and rolling and than adhesion) and transendothelial migration. VCAM-1 is almost not expressed under physiological conditions. However, under appropriate pro-inflammatory conditions where the endothelium is exposed to inflammatory cytokines such as tumour necrosis factor-alpha or IL-1b and becomes activated, VCAM-1 gene expression is rapid elevated by the vascular endothelium. There is also a soluble form of VCAM-1 which is angiogenic and chemotactic for endothelial cells. sVCAM-1 is up-regulated in several disease states (eg, myocardial infarction, type 2 diabetes mellitus, primary antiphospholipid syndrome, and rheumatoid arthritis).
Product Categories/Family for anti-VCAM-1 antibody
References
1. Thornhill, M et al; Tumor necrosis factor combines with IL-4 or IFN-gamma to selectively enhance endothelial cells adhesiveness for T cells. The contribution of vascular cell adhesion molecule-1-dependent and -independent binding mechanisms. J Immunology 1991, 146: 592
2. Van der Vieren, M. et al; The Leukocyte Integrin alpha4beta2- binds VCAM-1: Evidence for a binding interface between I domain and VCAM-1. J Immunol 1999, 163:1984
3. Dienst, A et al; Specific occlusion of murine andHuman tumor vasculature by VCAM-1-Targeted recombinant fusion protein. J Natl Cancer Inst 2005, 97 :733
4. Wijbrandt, C et al; The clinical response to infliximab in rheumatoid arthritis is in part dependent on pretreatment tumour necrosis factor ; expression in the synovium. Ann Rheum Dis 2008, 67:1139
5. Roussel, L et al; IL-17 Promotes p38 MAPK-dependent endothelial activation enhancing- neutrophil recruitment to sites of inflammation. J immunol. 2010, 184:4531

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
NCBI Official Full Name
vascular cell adhesion protein 1
NCBI Official Synonym Full Names
vascular cell adhesion molecule 1
NCBI Official Symbol
Vcam1
NCBI Official Synonym Symbols
VCAM1B
NCBI Protein Information
vascular cell adhesion protein 1
UniProt Protein Name
Vascular cell adhesion protein 1
UniProt Gene Name
Vcam1
UniProt Synonym Gene Names
Vcam-1; V-CAM 1; VCAM-1

NCBI Description

binds integrin very late antigen (VLA4); plays a role in cell adhesion [RGD, Feb 2006]

Uniprot Description

Important in cell-cell recognition. Appears to function in leukocyte-endothelial cell adhesion. Interacts with integrin alpha-4/beta-1 (ITGA4/ITGB1) on leukocytes, and mediates both adhesion and signal transduction. The VCAM1/ITGA4/ITGB1 interaction may play a pathophysiologic role both in immune responses and in leukocyte emigration to sites of inflammation.

Research Articles on VCAM-1

Similar Products

Product Notes

The VCAM-1 vcam1 (Catalog #AAA584876) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The VCAM-1, Human, mAb 1G11B1, biotinylated reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's VCAM-1 can be used in a range of immunoassay formats including, but not limited to, Flow Cytometry (FC/FACS), Immunohistochemistry (IHC) Frozen, Functional Studies (FS), Immunoassay (IA), Immunofluorescence (IF). The typical starting working dilution is 1:50. IHC-F: Cryostatic sections were fixed in acetone, and incubated with mAb at 10ug/ml in PBS/0.1% tween20 FC: 1ug mAb per 1x105 cells FS: Stimulated EC were preincubated for 30' at 37 degree C with mAb and than used in adhesion assay with T-cells IP: precleared EC lysates were immunoprecipitated with mAB and analyzed by 7.5% SDS-PAGE under reducing conditions. Researchers should empirically determine the suitability of the VCAM-1 vcam1 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "VCAM-1, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.