Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only) (Rat Eotaxin PicoKine ELISA Kit standard curve )

Rat CCL11/Eotaxin PicoKine ELISA Kit | Ccl11 elisa kit

Rat CCL11/Eotaxin PicoKine ELISA Kit

Gene Names
Ccl11; Scya11
Reactivity
Rat
Synonyms
CCL11/Eotaxin PicoKine; Rat CCL11/Eotaxin PicoKine ELISA Kit; Eotaxin; C-C motif chemokine 11; CCL 11; CCL11; CCL11_HUMAN; Chemokine (C-C motif) ligand 11; Chemokine C C motif ligand 11; Chemokine CC Motif Ligand 11; Chemokine ligand 11; Eosinophil Chemotactic P; Eosinophil chemotactic protein; Eotaxin 1; SCYA 11; SCYA11; chemokine (C-C motif) ligand 11; Ccl11 elisa kit
Ordering
For Research Use Only!
Reactivity
Rat
Specificity
Natural and recombinant rat Eotaxin
Sequence Length
97
Assay Range
15.6pg/ml-1000pg/ml
Sensitivity
<10pg/ml
Sample
For quantitative detection of rat Eotaxin in cell culture supernates, serum and plasma(EDTA, citrate).
Immunogen
E Coli, H24-P97
Assay Procedure Step 1
Aliquot 0.1ml per well of the 1000pg/ml, 500pg/ml, 250pg/ml, 125pg/ml, 62.5pg/ml, 31.2pg/ml, 15.6pg/ml rat Eotaxin standard solutions into the precoated 96-well plate. Add 0.1ml of the sample diluent buffer into the control well (Zero well). Add 0.1ml of each properly diluted sample of rat cell culture supernatants, serum or plasma(EDTA, citrate) to each empty well. It is recommended that each rat Eotaxin standard solution and each sample be measured in duplicate.
Intra-Assay Precision
Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|74.6|267|646|101.4|309|718
Standard deviation|3.80|14.55|36.18|6.49|22.25|56.72
CV(%)|5.1|6.2|5.6|6.4|7.2|7.9
Sample Data
Concentration(pg/ml)|0|15.6|31.2|62.5|125|250|500|1000
O.D.|0.015|0.104|0.151|0.286|0.579|1.050|2.051|2.562
Anticoagulant
EDTA or Citrate
Preparation and Storage
Store at 4 degree C for 6 months, at -20 degree C for 12 months. Avoid multiple freeze-thaw cycles.

Typical Testing Data/Standard Curve (for reference only)

(Rat Eotaxin PicoKine ELISA Kit standard curve )

Typical Testing Data/Standard Curve (for reference only) (Rat Eotaxin PicoKine ELISA Kit standard curve )
Related Product Information for Ccl11 elisa kit
Principle of the assay: Rat Eotaxin ELISA Kit was based on standard sandwich enzyme-linked immune-sorbent assay technology. A monoclonal antibody from mouse specific for Eotaxin has been precoated onto 96-well plates. Standards(Expression system for standard: E Coli, Immunogen sequence: H24-P97) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for Eotaxin is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with PBS or TBS buffer. HRP substrate TMB was used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the rat Eotaxin amount of sample captured in plate.

Background: Eotaxin, also known as CCL11, is a potent inducer of eosinophil chemotaxis and is considered as a selective ligand of the CC chemokine receptor 3 (CCR3), which is expressed on eosinophils, basophils, and Th2 lymphocytes. Eotaxin is assumed to be involved in eosinophilic inflammatory diseases such as atopic dermatitis, allergic rhinitis, asthma and parasitic infections. The gene maps to chromosome 17 and is expressed constitutively at high levels in small intestine and colon, and at lower levels in various other tissues. The deduced mature protein sequence is 66% identical to human monocyte chemoattractant protein-1, and 60% identical to guinea pig eotaxin.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
10,851 Da
NCBI Official Full Name
eotaxin
NCBI Official Synonym Full Names
C-C motif chemokine ligand 11
NCBI Official Symbol
Ccl11
NCBI Official Synonym Symbols
Scya11
NCBI Protein Information
eotaxin
UniProt Protein Name
Eotaxin
Protein Family
UniProt Gene Name
Ccl11
UniProt Synonym Gene Names
Scya11
UniProt Entry Name
CCL11_RAT

NCBI Description

mouse homolog is an eosinophil chemoattractant [RGD, Feb 2006]

Uniprot Description

In response to the presence of allergens, this protein directly promotes the accumulation of eosinophils, a prominent feature of allergic inflammatory reactions.

Research Articles on Ccl11

Similar Products

Product Notes

The Rat Ccl11 ccl11 (Catalog #AAA177626) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA177626 ELISA Kit recognizes Rat Ccl11. It is sometimes possible for the material contained within the vial of "CCL11/Eotaxin PicoKine, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.