Typical Testing Data/Standard Curve (for reference only) (Typical Standard Curve for the Cortisol EIA Kit (Enzyme Immunoassay) StressXpress - SKT-201. Assay Type: Sandwich EIA. Detection Method: Colorimetric Assay. Assay Range: 100 - 3200 pg/ml.)

General Cortisol ELISA Kit

Cortisol ELISA Kit

Reactivity
General
Applications
ELISA
Synonyms
Cortisol; Cortisol ELISA Kit; Quantitative colorimetric detection of cortisol; (11beta)-11; 17; 21-trihydroxypregn-4-ene-3; 20-dione EIA Kit; Cortisol elisa kit
Ordering
For Research Use Only!
Reactivity
General
Applicable Applications for Cortisol elisa kit
ELISA (EIA)
Intra-assay Precision
Three human samples were diluted with Assay Buffer and run in replicates of 20 in an assay.
Inter-assay Precision
Three human samples were diluted with Assay Buffer and run in duplicates in ten assays run over multiple days by four operators.
Preparation and Storage
Store at 4 degree C
Shipping Temperature: Blue Ice

Typical Testing Data/Standard Curve (for reference only)

(Typical Standard Curve for the Cortisol EIA Kit (Enzyme Immunoassay) StressXpress - SKT-201. Assay Type: Sandwich EIA. Detection Method: Colorimetric Assay. Assay Range: 100 - 3200 pg/ml.)

Typical Testing Data/Standard Curve (for reference only) (Typical Standard Curve for the Cortisol EIA Kit (Enzyme Immunoassay) StressXpress - SKT-201. Assay Type: Sandwich EIA. Detection Method: Colorimetric Assay. Assay Range: 100 - 3200 pg/ml.)

Testing Data

(Linearity was determined by taking two human urine samples diluted 1:140, one with a low diluted cortisol level of 163.9 pg/mL and one with a higher diluted level of 2,974.9 pg/mL and mixing them in the ratios given below. The measured concentrations were compared to the expected values based on the ratios used.)

Testing Data (Linearity was determined by taking two human urine samples diluted 1:140, one with a low diluted cortisol level of 163.9 pg/mL and one with a higher diluted level of 2,974.9 pg/mL and mixing them in the ratios given below. The measured concentrations were compared to the expected values based on the ratios used.)
Related Product Information for Cortisol elisa kit
Background/Introduction: Cortisol, C21H30O5, (hydrocortisone, compound F) is the primary glucocorticoid produced and secreted by the adrenal cortex. It is often referred to as the "stress hormone" as it is involved in the response to stress and it affects blood pressure, blood sugar levels, and other actions of stress adaptation. Immunologically, cortisol functions as an important anti-inflammatory and plays a role in hypersensitivity, immunosuppression, and disease resistance1. In the metabolic aspect, cortisol promotes gluconeogenesis, liver glycogen deposition, and the reduction of glucose utilization2. Production of cortisol follows an ACTH-dependent circadian rhythm, with a peak level in the morning and decreasing levels throughout the day. Most serum cortisol, all but about 4%, is bound to proteins including corticosteroid binding globulin and serum albumin1,3. Only free cortisol is available to most receptors and it is through these receptors that physiological processes are modulated. Abnormal cortisol levels are being evaluated for correlation with a variety of different conditions, such as prostate cancer4, depression5, and schizophrenia6. It is already known that abnormal levels of cortisol are involved in Cushing's Syndrome and Addision's disease7.
Product Categories/Family for Cortisol elisa kit
References
1. E. Friess, et al., Eur J Clin Invest, 2000, 30, Suppl 3:46-50.
2. Freeman, Scott, 200
2. Biological Science. Prentice Hall; 2nd Pkg edition (December 30, 2004).
3. C. Longscope., J. Endocrinology, 1996,, Suppl S125-S127.
4. J. Herbert, Lancet, 1995 345, 1193-1194.
5. A. Michael, et al., Biol. Psychiatry, 2000, 48, 989-95.
6. C.R. Dequet and D.J. Wallace, Current Opin. Ivest. Drugs, 2001, 8, 1045-53.
7. W.M. Jeffries, Med. Hypotheses, 1998, 51, 114-4.

Similar Products

Product Notes

The General Cortisol (Catalog #AAA8005732) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA8005732 ELISA Kit recognizes General Cortisol. AAA Biotech's Cortisol can be used in a range of immunoassay formats including, but not limited to, ELISA (EIA). Researchers should empirically determine the suitability of the Cortisol for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Cortisol, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.