Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Testing Data

CD16/FCGR3 ELISA Pair Set | FCGR3 elisa pair set

CD16/FCGR3 Matched ELISA Antibody Pair Set, Rhesus

Synonyms
CD16/FCGR3; CD16/FCGR3 Matched ELISA Antibody Pair Set; Rhesus; Rhesus CD16/FCGR3 ELISA Pair Set; Fc receptor; IgG; low affinity III; FCGR3 elisa pair set
Ordering
For Research Use Only!
Specificity
Quantitative determination of Rhesus CD16/FCGR3
Assay Type
Solid Phase Sandwich ELISA
Detection Range
12.5-800pg/mL
Sensitivity
12.5pg/ml
Materials Provided
1. Capture Antibody 0.07 mg/mL of mouse anti-Rhesus FCGR3 monoclonal antibody. Dilute to a working concentration of 2ug/mL in CBS before coating.
2. Detection Antibody 0.25 mg/mL mouse anti-Rhesus FCGR3 monoclonal antibody conjugated to horseradish-peroxidase (HRP). Dilute to working concentration of 0.5ug/mL in detection antibody dilution buffer before use.
3. Standard Each vial contains 31 ng of recombinant Rhesus FCGR3. Reconstitute with 1 mL detection antibody dilution buffer. After reconstitution, store at -20 degree C to -80 degree C in a manual defrost freezer. A seven-point standard curve using 2-fold serial dilutions in sample dilution buffer, and a high standard of 0.8ng/mL is recommended.
Preparation and Storage
Capture Antibody: Aliquot and store at -20 degree C to -80 degree C for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles.
Detection Antibody: Protect it from prolonged exposure to light. Aliquot and store at -20 degree C to -80 degree C and for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles.
Standard: Store lyophilized standard at -20 degree C to -80 degree C for up to 6 months from date of receipt. Aliquot and store the reconstituted Standard at -80 degree C for up to 1 month. Avoid repeated freeze-thaw cycles.

Testing Data

Testing Data
Related Product Information for FCGR3 elisa pair set
Fc receptors bind the most common class of antibody, IgG, are called Fc gamma receptors (FcgammaR). FcgammaR is divided into three classes, Fc gamma RI (CD64), Fc gamma RII (CD32), and Fc gamma RIII (CD16). CD16 protein is a multifunctional, low/intermediate affinity receptor, which belongs to the immunoglobulin superfamily. It is found on the surface of natural killer cells, neutrophil polymorphonuclear leukocytes, monocytes and macrophages. Mouse CD16 is encoded by a single gene, while, human CD16 is expressed as two distinct forms (CD16a/FcgammaRIIIa and CD16b/FcgammaRIIIb) encoded by two different highly homologous genes in a cell type-specific manner. CD16 is involved in phagocytosis, secretion of enzymes, inflammatory mediators, antibody-dependent cellular cytotoxicity (ADCC), and clearance of immune complexes.

This CD16/FCGR3 Matched ELISA Antibody Pair Set, Rhesus is a solid phase sandwich ELISA for quantitative determination of Rhesus CD16/FCGR3. It contains Rhesus CD16/FCGR3 capture antibody, Rhesus CD16/FCGR3 detector antibody (HRP) and a highly purified HEK293-expressed recombinant Rhesus CD16/FCGR3 protein.
Product Categories/Family for FCGR3 elisa pair set
References
Edberg JC, et al. (2002) Genetic linkage and association of Fcgamma receptor IIIA (CD16A) on chromosome 1q23 with human systemic lupus erythematosus. Arthritis Rheum. 46(8): 2132-40.Li P, et al. (2002) Recombinant CD16A-Ig forms a homodimer and cross-blocks the ligand binding functions of neutrophil and monocyte Fcgamma receptors. Mol Immunol. 38(7): 527-38.Li P, et al. (2007) Affinity and kinetic analysis of Fcgamma receptor IIIa (CD16a) binding to IgG ligands. J Biol Chem. 282(9): 6210-21.

Similar Products

Product Notes

The FCGR3 (Catalog #AAA8118547) is an ELISA Pair Set and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "CD16/FCGR3, ELISA Pair Set" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.