Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Flow Cytometry (FC/FACS) (Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood).)

Mouse anti-Human CD200 Monoclonal Antibody | anti-CD200 antibody

Anti-Hu CD200 Alexa Fluor647

Gene Names
CD200; MRC; MOX1; MOX2; OX-2
Reactivity
Human
Applications
Flow Cytometry, Functional Assay
Purity
The purified antibody is conjugated with Alexa Fluor647 under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Synonyms
CD200; Monoclonal Antibody; Anti-Hu CD200 Alexa Fluor647; MRC; MOX; OX-2; CD200 molecule; anti-CD200 antibody
Ordering
Host
Mouse
Reactivity
Human
Clonality
Monoclonal
Isotype
Mouse IgG1 kappa
Clone Number
OX-104
Specificity
The mouse monoclonal antibody OX-104 recognizes an extracellular epitope of CD200, a type-1 glycoprotein of the immunoglobulin superfamily, which is expressed in neurons, B and T cell subsets, keratinocytes, follicular dendritic cells, and ovarian cells.
Purity/Purification
The purified antibody is conjugated with Alexa Fluor647 under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Form/Format
Stabilizing phosphate buffered saline (PBS) solution containing 15mM sodium azide
Applicable Applications for anti-CD200 antibody
Flow Cytometry (FC/FACS) (QC tested)
Application Notes
FC/FACS: The reagent is designed for analysis of human blood cells using 4ul reagent/100ul of whole blood or 106 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests.
Conjugation
Alexa Fluor647
Immunogen
recombinant human CD200
Preparation and Storage
Store in the dark at 2-8 degree C. Do not freeze. Avoid prolonged exposure to light. Do not use after expiration date stamped on vial label.

Flow Cytometry (FC/FACS)

(Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood).)

Flow Cytometry (FC/FACS) (Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood).)

Flow Cytometry (FC/FACS)

(Flow cytometry multicolor surface staining of human lymphocytes stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood) and anti-human CD3 (UCHT1) PE antibody (20 ul reagent / 100 ul of peripheral whole blood).)

Flow Cytometry (FC/FACS) (Flow cytometry multicolor surface staining of human lymphocytes stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood) and anti-human CD3 (UCHT1) PE antibody (20 ul reagent / 100 ul of peripheral whole blood).)

Flow Cytometry (FC/FACS)

(Separation of human CD200 positive CD3 negative lymphocytes (red-filled) from CD200 negative T cells (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood).)

Flow Cytometry (FC/FACS) (Separation of human CD200 positive CD3 negative lymphocytes (red-filled) from CD200 negative T cells (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using anti-human CD200 (OX-104) Alexa Fluor 647 antibody (4 ul reagent / 100 ul of peripheral whole blood).)
Related Product Information for anti-CD200 antibody
CD200 (also known as OX2 or MRC) is a type-1 membrane glycoprotein, which contains two extracellular immunoglobulin domains, transmembrane domain and cytoplasmic domain. It is expressed by neuronal cells, B and T cell subsets, follicular dendritic cells, keratinocytes, and ovarian cells. The interaction between CD200 and its receptor CD200R results in macrophage activation (IL-6 production), inhibition of mast cell degranulation along with reduced TNF-alpha and IL-13 secretion and overall attenuation of the activation status of lymphocytes. It seems CD200 is also involved in maternal tolerance and its decreased expression in hair follicle correlates with follicular miniaturization.
References
*Garza LA, Yang CC, Zhao T, Blatt HB, Lee M, He H, Stanton DC, Carrasco L, Spiegel JH, Tobias JW, Cotsarelis G: Bald scalp in men with androgenetic alopecia retains hair follicle stem cells but lacks CD200-rich and CD34-positive hair follicle progenitor cells. J Clin Invest. 2011 Feb;121(2):613-22, URL: http://www.ncbi.nlm.nih.gov/pubmed/21206086,*Li Y, Zhao LD, Tong LS, Qian SN, Ren Y, Zhang L, Ding X, Chen Y, Wang YX, Zhang W, Zeng XF, Zhang FC, Tang FL, Zhang X, Ba DN, He W, Cao XT, Lipsky PE: Aberrant CD200/CD200R1 expression and Functional Application (FUNC)tion in systemic lupus erythematosus contributes to abnormal T-cell responsiveness and dendritic cell activity. Arthritis Res Ther. 2012 May 23;14(3):R123. doi: 10.1186/ar3853., URL: https://www.ncbi.nlm.nih.gov/pubmed/term=Li+Y%2C+,*Sopp P, Werling D, Baldwin C: Sopp P, Werling D, Baldwin C: Vet Immunol Immunopathol. 2007 Sep 15;119(1-2):106-14, URL: http://www.ncbi.nlm.nih.gov/pubmed/term=sopp+p+we,*Shiratori I, Yamaguchi M, Suzukawa M, Yamamoto K, Lanier LL, Saito T, Arase H: Down-regulation of basophil Functional Application (FUNC)tion by human CD200 and human herpesvirus-8 CD200. J Immunol. 2005 Oct 1;175(7):4441-9., URL: http://www.ncbi.nlm.nih.gov/pubmed/term=shiratori,*Colmont CS, Benketah A, Reed SH, Hawk NV, Telford WG, Ohyama M, Udey MC, Yee CL, Vogel JC, Patel GK: CD200-expressing human basal cell carcinoma cells initiate tumor growth. Proc Natl Acad Sci U S A. 2013 Jan 22;110(4):1434-9., URL: http://www.ncbi.nlm.nih.gov/pubmed/term=colmont+c,*Foster-Cuevas M, Wright GJ, Puklavec MJ, Brown MH, Barclay AN: Human herpesvirus 8 K14 protein mimics CD200 in down-regulating macrophage activation through CD200 receptor. J Virol. 2004 Jul;78(14):7667-76., URL: http://www.ncbi.nlm.nih.gov/pubmed/15220441,*Meuth SG, Simon OJ, Grimm A, Melzer N, Herrmann AM, Spitzer P, Landgraf P, Wiendl H: CNS inflammation and neuronal degeneration is aggravated by impaired CD200-CD200R-mediated macrophage silencing. J Neuroimmunol. 2008 Feb;194(1-2):62-9., URL: http://www.ncbi.nlm.nih.gov/pubmed/18164423

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
UniProt Accession #
Molecular Weight
32,975 Da
NCBI Official Full Name
OX-2 membrane glycoprotein
NCBI Official Synonym Full Names
CD200 molecule
NCBI Official Symbol
CD200
NCBI Official Synonym Symbols
MRC; MOX1; MOX2; OX-2
NCBI Protein Information
OX-2 membrane glycoprotein
UniProt Protein Name
OX-2 membrane glycoprotein
UniProt Gene Name
CD200
UniProt Synonym Gene Names
MOX1; MOX2

NCBI Description

This gene encodes a type I membrane glycoprotein containing two extracellular immunoglobulin domains, a transmembrane and a cytoplasmic domain. This gene is expressed by various cell types, including B cells, a subset of T cells, thymocytes, endothelial cells, and neurons. The encoded protein plays an important role in immunosuppression and regulation of anti-tumor activity. Alternative splicing results in multiple transcript variants encoding different isoforms. [provided by RefSeq, Jan 2016]

Uniprot Description

Costimulates T-cell proliferation. May regulate myeloid cell activity in a variety of tissues.

Research Articles on CD200

Similar Products

Product Notes

The CD200 cd200 (Catalog #AAA1802050) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The Anti-Hu CD200 Alexa Fluor647 reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's CD200 can be used in a range of immunoassay formats including, but not limited to, Flow Cytometry (FC/FACS) (QC tested). FC/FACS: The reagent is designed for analysis of human blood cells using 4ul reagent/100ul of whole blood or 106 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests. Researchers should empirically determine the suitability of the CD200 cd200 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "CD200, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.