Typical Testing Data/Standard Curve (for reference only)

Luteinizing Hormone ELISA Kit | LH elisa kit

Luteinizing Hormone (LH)

Synonyms
Luteinizing Hormone; Luteinizing Hormone (LH); LH elisa kit
Ordering
For Research Use Only!
Specificity
This kit exhibits no detectable cross reaction with human; FSH, TSH, Prolactin, or GH. But there is cross reaction with hCG in this assay. After pregnancy hCG levels are elevated, therefore the use of LH ELISA Kit is not recommended during pregnancy or immediately post-parturition.
Samples
Serum
Assay Type
Sandwich
Sensitivity
The minimal detectable concentration of LH by this assay is estimated to be 3 mIU/ml.
Intended Uses
This Human LH ELISA Kit is to be used for the in vitro quantitative determination of human luteinizing hormone (LH) concentrations in serum. This kit is intended FOR LABORATORY RESEARCH USE ONLY and is not for use in therapeutic procedures.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for LH elisa kit
Principle of the assay: This LH enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been precoated with a monoclonal antibody specific for LH. Standards or samples are then added to the microtiter plate wells and LH if present, will bind to the antibody pre-coated on the wells. In order to quantitate the amount of LH present in the sample, a standardized preparation of horseradish peroxidase (HRP)-conjugated monoclonal antibody, specific for LH are added to each well to "sandwich" the LH immobilized on the plate. The microtiter plate undergoes incubation, then the wells are thoroughly washed to remove all unbound components. Next, a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain LH and enzyme-conjugated antibody will exhibit a change in colour. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the colour change is measured spectrophotometrically at a wavelength of 450 nm. In order to measure the concentration of LH in the sample, this Human LH ELISA Kit includes a set of calibration standards (6 standards). The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density (O.D.) versus LH concentration (mIU/mL). The concentration of LH in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Product Categories/Family for LH elisa kit

Similar Products

Product Notes

The LH (Catalog #AAA590031) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Luteinizing Hormone, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.