Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Flow Cytometry (FC/FACS) (Flow cytometry analysis (surface staining) of human peripheral blood with anti-HLA-class I (MEM-147) PE.)

Mouse anti-Human HLA Class I Antibody | anti-HLA-C antibody

Anti-HLA Class I PE

Gene Names
HLA-C; MHC; HLAC; HLC-C; D6S204; PSORS1; HLA-JY3
Reactivity
Human
Applications
Flow Cytometry, Functional Assay
Purity
The purified antibody is conjugated with R-phycoerythrin (PE) under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Synonyms
HLA Class I; Anti-HLA Class I PE; anti-HLA-C antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human
Isotype
IgG1
Clone Number
MEM-147
Specificity
The antibody MEM-147 reacts with an extracellular epitope of all human classical MHC Class I molecules in native cell-surface forms (e.g. it recognizes native HLA-A2 in cytofluorometry and immunoprecipitation but not in Western blotting). MHC Class I molecules (MHC Class Ia) are expressed on the surface of all human nucleated cell types. The antibody MEM-147 is positive in Western blotting (non-reducing conditions) only with most HLA-B and HLA-C molecules, but not HLA-A. Reactivity is very similar to the classical antibody W6/32.
Purity/Purification
The purified antibody is conjugated with R-phycoerythrin (PE) under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Form/Format
Stabilizing phosphate buffered saline (PBS) solution containing 15 mM sodium azide
Concentration
0.1 mg/ml (varies by lot)
Sequence Length
298
Applicable Applications for anti-HLA-C antibody
Flow Cytometry (FC/FACS)
Application Notes
FC/FACS: QC tested
Immunogen
PHA-activated peripheral blood lymphocytes
Conjugation
PE
Preparation and Storage
Store in the dark at 2-8 degree C. Do not freeze. Avoid prolonged exposure to light.

Flow Cytometry (FC/FACS)

(Flow cytometry analysis (surface staining) of human peripheral blood with anti-HLA-class I (MEM-147) PE.)

Flow Cytometry (FC/FACS) (Flow cytometry analysis (surface staining) of human peripheral blood with anti-HLA-class I (MEM-147) PE.)
Related Product Information for anti-HLA-C antibody
HLA-class I major histocompatibility (MHC) antigens are intrinsic membrane glycoproteins expressed on nucleated cells and noncovalently associated with an invariant beta2 microglobulin. They carry foreign determinants important for immune recognition by cytotoxic T cells, thus important for anti-viral and anti-tumour defence. Human HLA-class I antigens are represented by HLA-A, HLA-B and HLA-C molecules.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Official Full Name
HLA class I, partial
NCBI Official Synonym Full Names
major histocompatibility complex, class I, C
NCBI Official Symbol
HLA-C
NCBI Official Synonym Symbols
MHC; HLAC; HLC-C; D6S204; PSORS1; HLA-JY3
NCBI Protein Information
HLA class I histocompatibility antigen, C alpha chain

NCBI Description

HLA-C belongs to the HLA class I heavy chain paralogues. This class I molecule is a heterodimer consisting of a heavy chain and a light chain (beta-2 microglobulin). The heavy chain is anchored in the membrane. Class I molecules play a central role in the immune system by presenting peptides derived from endoplasmic reticulum lumen. They are expressed in nearly all cells. The heavy chain is approximately 45 kDa and its gene contains 8 exons. Exon one encodes the leader peptide, exons 2 and 3 encode the alpha1 and alpha2 domain, which both bind the peptide, exon 4 encodes the alpha3 domain, exon 5 encodes the transmembrane region, and exons 6 and 7 encode the cytoplasmic tail. Polymorphisms within exon 2 and exon 3 are responsible for the peptide binding specificity of each class one molecule. Typing for these polymorphisms is routinely done for bone marrow and kidney transplantation. Over one hundred HLA-C alleles have been described [provided by RefSeq, Jul 2008]

Research Articles on HLA-C

Similar Products

Product Notes

The HLA-C (Catalog #AAA1801032) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The Anti-HLA Class I PE reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's HLA Class I can be used in a range of immunoassay formats including, but not limited to, Flow Cytometry (FC/FACS). FC/FACS: QC tested. Researchers should empirically determine the suitability of the HLA-C for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "HLA Class I, Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.