Flow Cytometry (FC/FACS)

CD326 (EpCAM) Monoclonal Antibody | anti-CD326 antibody

Anti-Human CD326 (EpCAM)

Applications
Flow Cytometry, Functional Assay, ELISA
Purity
Protein A purified antibody from tissue culture supernatant was reacted with FITC. Unconjugated FITC was separated from antibody/FITC conjugate by desalting column. The antibody/FITC conjugate is at approximately 0.5 mg/ml with a Fluorescein/IgG molar rat
Synonyms
CD326 (EpCAM); Monoclonal Antibody; Anti-Human CD326 (EpCAM); anti-CD326(EpCAM)FITC Conjugate; Monoclonal anti-human CD326(EpCAM)/FITC*; Human Embryonic Antigen; anti-CD326 antibody
Ordering
For Research Use Only!
Clonality
Monoclonal
Isotype
IgG1K
Clone Number
ANC8D4
Purity/Purification
Protein A purified antibody from tissue culture supernatant was reacted with FITC. Unconjugated FITC was separated from antibody/FITC conjugate by desalting column. The antibody/FITC conjugate is at approximately 0.5 mg/ml with a Fluorescein/IgG molar rat
Form/Format
FITC
Applicable Applications for anti-CD326 antibody
Flow Cytometry (FC/FACS), ELISA (EIA)
Immunogen
Recombinant soluble human CD326
Buffer
50 mM Sodium Phosphate pH 7.5, 100 mM Potassium Chloride, 150mM NaCl, 5% Glycerol, 0.2% BSA, 0.04% NaN3 (as a preservative).
Performance
Cultured human SW480 cells were harvested by EDTA. Five x 105 cells per tube were pre incubated with 20 ul of 300 ug/ml human IgG (to block non specific binding), after which they were incubated 45 minutes on ice with 80 ul of product at a 1:50 dilution (10 ug/ml). They were then washed three times, fixed and analyzed by FACS. Cells stained positive with a mean shift of 1.30 log10 fluorescent units when compared to a Mouse IgG1/FITC negative control at a similar concentration. Binding was blocked when cells were pre incubated 10 minutes with 20 ul of 0.5 mg/ml anti-CD326 antibody.
Preparation and Storage
Store at 2 - 5 degree C. Freeze/Thawing is not recommended. Protect from light.
Product should retain activity for at least 12 months after shipping date when stored as recommended.

Flow Cytometry (FC/FACS)

Flow Cytometry (FC/FACS)
Related Product Information for anti-CD326 antibody
Human CD326 (EpCAM, EGP2, HEA) is a 40kD glycoprotein expressed on epithelial cells and many carcinomas. It is an adhesion molecule whose function is implicated in carcinogenesis and erythropoesis. CD326 has great potential as a therapeutic and marker for cancer (2, 3).
Product Categories/Family for anti-CD326 antibody
References
1) Rao CG, et al. (2005) Int. J. Oncol 27: 49 2) Baeuerle PA, O Gires. (2007) Brit J Cancer 96: 417-423. 3) Patriarca C, H Mellstedt, et al. (2012) Cancer Treatment Reviews 38(1): 68-75.

Similar Products

Product Notes

The CD326 (Catalog #AAA666903) is an Antibody and is intended for research purposes only. The product is available for immediate purchase. AAA Biotech's CD326 (EpCAM) can be used in a range of immunoassay formats including, but not limited to, Flow Cytometry (FC/FACS), ELISA (EIA). Researchers should empirically determine the suitability of the CD326 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "CD326 (EpCAM), Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.