Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Varicella zoster virus IgA (VZV-IgA) Standard Curve.)

Human Varicella Zoster Virus IgA (VZV-IgA) ELISA Kit | VZV-IgA elisa kit

Human Varicella Zoster Virus IgA (VZV-IgA) ELISA Kit

Reactivity
Human
Synonyms
Varicella Zoster Virus IgA (VZV-IgA); Human Varicella Zoster Virus IgA (VZV-IgA) ELISA Kit; VZV-IgA elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
Human Varicella zoster virus IgA (VZV-IgA) ELISA Kit has high sensitivity and excellent specificity for detection of Human VZV-IgA. No significant cross-reactivity or interference between Human VZV-IgA and analogues was observed.
Assay Type
Sandwich ELISA (Quantitative)
Samples
Cell Culture Supernatants, Serum, Plasma, Other Biological Fluids
Detection Method
Colorimetric
Usage Notes
* Do not mix components from different kit lots or use reagents beyond the kit expiration date.
* Allow all reagents to warm to room temperature for at least 30 minutes before opening.
* Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
* Unused wells must be kept desiccated at 4 degree C in the sealed bag provided.
* Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
* It is recommended that all samples and standards be assayed in duplicate or triplicate.
Preparation and Storage
Store at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

(Fig.1. Human Varicella zoster virus IgA (VZV-IgA) Standard Curve.)

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Varicella zoster virus IgA (VZV-IgA) Standard Curve.)
Related Product Information for VZV-IgA elisa kit
Description: This Human Varicella zoster virus IgA (VZV-IgA) ELISA Kit employs a two-site sandwich ELISA to quantitate VZV-IgA in samples. An antibody specific for VZV-IgA has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any VZV-IgA present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for VZV-IgA is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of VZV-IgA bound in the initial step. The color development is stopped and the intensity of the color is measured.

Background: Varicella-Zoster Virus (human herpes virus 3, HHV-3) belongs to the a-subfamily of herpesviridae. The virus particles measure about 145 nm in diameter. They consist of doublestranded DNA, are surrounded by an icosahedral protein capsid and an envelope which contains both host cells and viral components. The virus is usually transmitted in respiratory secretions, and a single serotype causes varicella (Chickenpox), a highly infectious childhood disease, and zoster (shingles), a neurodermic disease; both diseases are found world-wide. Varicella is the acute disease which follows primary contact with the virus, whereas zoster is the response of the partially immune host to a reactivation of the varicella virus present in the body in latent form. Varicella is endemic, most commonly affected are children between 2 and 6 years of age. The course of disease is usually mild and complicated only in immunocompromised children. Rare fatal cases show multiple necrotic lesions in brain, lung (varicella pneumonia), kidneys (hemorrhagic nephritis), spleen, bone marrow, and occasionally in the intestinal tract. The lethality of varicella is below 0.1%. In the infrequent adult infections the disease is more severe, and complications are to be expected in about 5% of all cases. Zoster is of low incidence and appears with increasing frequency and severity with advancing age. Usually the process remains localized, generalization is frequently encountered in a state of immunosuppression. Fatal cases are very rare and nearly always caused by an underlying disease.

Similar Products

Product Notes

The Human VZV-IgA (Catalog #AAA9716360) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA9716360 ELISA Kit recognizes Human VZV-IgA. It is sometimes possible for the material contained within the vial of "Varicella Zoster Virus IgA (VZV-IgA), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.