Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Rota Virus (RV) Standard Curve.)

Human Rota Virus (RV) ELISA Kit | RV elisa kit

Human Rota Virus (RV) ELISA Kit

Reactivity
Human
Synonyms
Rota Virus (RV); Human Rota Virus (RV) ELISA Kit; RV elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
Human Rota Virus (RV) ELISA kit has high sensitivity and excellent specificity for detection of Human RV. No significant cross-reactivity or interference between Human RV and analogues was observed.
Assay Type
Sandwich ELISA (Quantitative)
Samples
Cell Culture Supernatants, Serum, Plasma, Other Biological Fluids
Detection Method
Colorimetric
Usage Notes
* Do not mix components from different kit lots or use reagents beyond the kit expiration date.
* Allow all reagents to warm to room temperature for at least 30 minutes before opening.
* Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
* Unused wells must be kept desiccated at 4 degree C in the sealed bag provided.
* Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
* It is recommended that all samples and standards be assayed in duplicate or triplicate.
Preparation and Storage
Store at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

(Fig.1. Human Rota Virus (RV) Standard Curve.)

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Rota Virus (RV) Standard Curve.)
Related Product Information for RV elisa kit
Description: This Human Rota Virus (RV) ELISA kit employs a two-site sandwich ELISA to quantitate RV in samples. An antibody specific for RV has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any RV present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for RV is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of RV bound in the initial step. The color development is stopped and the intensity of the color is measured.

Background: Rotavirus is a virus that infects the intestinal tract. You can get rotavirus more than once, but the first infection is usually the worst. This infection causes stomach upset and diarrhea. Babies and very young children who have rotavirus infections need to be watched closely, because they can become dehydrated very quickly. Dehydration occurs when the body loses water more quickly than it is replaced. When your child becomes dehydrated, severe health problems can arise. Rotavirus infections spread easily. Outbreaks usually occur in the winter and early spring. Rotavirus infections often spread in settings where many children are together, such as day care centers.

Similar Products

Product Notes

The Human RV (Catalog #AAA9716372) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA9716372 ELISA Kit recognizes Human RV. It is sometimes possible for the material contained within the vial of "Rota Virus (RV), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.