Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Nucleobindin 1 (NUCB1) ELISA Kit | NUCB1 elisa kit

Human Nucleobindin 1 (NUCB1) ELISA Kit

Reactivity
Human
Synonyms
Nucleobindin 1 (NUCB1); Human Nucleobindin 1 (NUCB1) ELISA Kit; NUC; CALNUC; NUCB1 elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of Nucleobindin 1 (NUCB1).
No significant cross-reactivity or interference between Nucleobindin 1 (NUCB1) and analogues was observed.
Sequence Length
461
Assay Type
Double-antibody Sandwich
Sample
Tissue Homogenates, Cell Lysates and Other Biological Fluids
Dectection Range
0.156-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.055ng/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nucleobindin 1 (NUCB1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nucleobindin 1 (NUCB1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for NUCB1 elisa kit
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Nucleobindin 1 (NUCB1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Nucleobindin 1 (NUCB1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Nucleobindin 1 (NUCB1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Nucleobindin 1 (NUCB1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Product Categories/Family for NUCB1 elisa kit

NCBI and Uniprot Product Information

NCBI GI #
UniProt Accession #
NCBI Official Full Name
Nucleobindin-1
UniProt Protein Name
Nucleobindin-1
Protein Family
UniProt Gene Name
NUCB1
UniProt Synonym Gene Names
NUC
UniProt Entry Name
NUCB1_HUMAN

Uniprot Description

NUCB1: Major calcium-binding protein of the Golgi. May have a role in calcium homeostasis. Belongs to the nucleobindin family.

Protein type: DNA-binding

Chromosomal Location of Human Ortholog: 19q13.33

Cellular Component: microtubule cytoskeleton; Golgi apparatus; extracellular space; membrane; ER-Golgi intermediate compartment

Molecular Function: protein binding; DNA binding; calcium ion binding

Similar Products

Product Notes

The Human NUCB1 nucb1 (Catalog #AAA2122083) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2122083 ELISA Kit recognizes Human NUCB1. It is sometimes possible for the material contained within the vial of "Nucleobindin 1 (NUCB1), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.