Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Testing Data (Fig-1: Induction of STAT6 activity by mIL-4 in STAT6 Leeporter Ba/F3 cells.)

STAT6 cell line

STAT6 Leeporter Luciferase Reporter-Ba/F3 Cell Line

Gene Names
STAT6; STAT6B; STAT6C; D12S1644; IL-4-STAT
Applications
Functional Assay
Synonyms
STAT6; STAT6 Leeporter Luciferase Reporter-Ba/F3 Cell Line; STAT6 Reporter Ba/F3 Cell Line; Signal Transducer and Activator of Transcription; STAT6 reporter; STAT6 luciferase reporter; STAT6 cell line; Signal Transducer and Activator of Transcription-6 cell line; STAT6 reporter cell line; cell line; stable cell line; reporter cell line; luciferase; luciferase reporter cell line; leeporter; leeporter(TM); luciferase reporter; luciferase cell line; Ba/F3 cell line; Ba/F4 cell line; luciferase assay
Ordering
For Research Use Only!
Form/Format
Each vial contains 2 ~ 3 x 10^6 cells in 1 ml of 90% FBS + 10% DMSO.
Sequence Length
737
Applicable Applications for STAT6 cell line
Functional Assay
Application Notes
Monitor the STAT6 signaling pathway activity. Screen for activators or inhibitors of the STAT6 signaling pathway. Culture conditions: Cells should be grown at 37 degree C with 5% CO2 using RPMI medium supplemented with 10% heat-inactivated FBS, 1 mM sodium pyruvate, 10 mM HEPES and 1% Pen/Strep, plus 5 ng/ml mIL-3 (Note: mIL-3 is essential for Ba/F3 cell maintenance), plus 3 ug/ml of Puromycin. (Note: The parental Ba/F3-Puro cell line (Part #14135CCL) is a blank vector-transfected stable cell line which also requires 3 ug/ml of Puromycin for cell culture maintenance! Puromycin can be omitted during the reporter cell assays). It is recommended to quickly thaw the frozen cells upon receipt or from liquid nitrogen in a 37 degree C water-bath, transfer to a tube containing 10 ml of growth medium without Puromycin, spin down cells, resuspend cells in pre-warmed growth medium without Puromycin, transfer resuspended cells to T25 flask and culture in 37 degree C -CO2 incubator. Monitor the cell viability by counting cells daily for 1~3 days until cells completely recover viability as cells are doubling daily. Once cells are over 90% confluent, harvest cells by centrifugation and passage cells. At first passage, switch to growth medium containing Puromycin. Cells should be split before they reach complete confluence. To passage the cells, transfer cells to a tube, spin down cells, resuspend cells and seed appropriate aliquots of cell suspension into new culture vessels. Subcultivation ration = 1:10 to 1:20 weekly. To achieve satisfactory results, cells should not be passaged over 16 times. Functional validation: A. Response of STAT6 Leeporter - Ba/F3 cells to mIL-4. 1. Harvest STAT6 Leeporter - Ba/F3 cells and seed cells into a white solid-bottom 96-well microplate in 100 ul of growth medium without IL-3 at 1 x 10^5 cells/well. 2. Right after plating cells, stimulate cells with various concentrations of mouse IL-4 and incubate cells at 37 degree C in a CO2 incubator for 6-16 hours. 3. Add 50 ul of luciferase assay reagent per well. 4. Incubate at room temperature for 1-5 minutes and measure luminescence using a microplate luminometer.
Shipping Note
Product available only in the USA.
Dry Ice Shipment
Extra charge fee may add to your shipping cost as dry ice is required to ship this product.
Preparation and Storage
Immediately upon receipt, store in liquid nitrogen.

Testing Data

(Fig-1: Induction of STAT6 activity by mIL-4 in STAT6 Leeporter Ba/F3 cells.)

Testing Data (Fig-1: Induction of STAT6 activity by mIL-4 in STAT6 Leeporter Ba/F3 cells.)
Related Product Information for STAT6 cell line
The STAT6 Leeporter Luciferase Reporter cell line is a stably transfected Ba/F3 cell line which expresses Renilla luciferase reporter gene under the transcriptional control of the STAT6 responsive promoter, so that the cell line is designed to measure the transcriptional activity of STAT6. Signal Transducer and Activator of Transcription 6 (STAT6) is a member of the STAT transcription factor family and plays an important role in adaptive immunity by transducing signals from extracellular cytokines including IL-4. The STAT6 induction by IL-4 is shown in Figure 1.
Product Categories/Family for STAT6 cell line

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
NCBI Official Full Name
signal transducer and activator of transcription 6 isoform 2
NCBI Official Synonym Full Names
signal transducer and activator of transcription 6
NCBI Official Symbol
STAT6
NCBI Official Synonym Symbols
STAT6B; STAT6C; D12S1644; IL-4-STAT
NCBI Protein Information
signal transducer and activator of transcription 6

NCBI Description

The protein encoded by this gene is a member of the STAT family of transcription factors. In response to cytokines and growth factors, STAT family members are phosphorylated by the receptor associated kinases, and then form homo- or heterodimers that translocate to the cell nucleus where they act as transcription activators. This protein plays a central role in exerting IL4 mediated biological responses. It is found to induce the expression of BCL2L1/BCL-X(L), which is responsible for the anti-apoptotic activity of IL4. Knockout studies in mice suggested the roles of this gene in differentiation of T helper 2 (Th2) cells, expression of cell surface markers, and class switch of immunoglobulins. Alternative splicing results in multiple transcript variants.[provided by RefSeq, May 2010]

Research Articles on STAT6

Similar Products

Product Notes

The STAT6 (Catalog #AAA669346) is a Cell Line and is intended for research purposes only. The product is available for immediate purchase. AAA Biotech's STAT6 can be used in a range of immunoassay formats including, but not limited to, Functional Assay. Monitor the STAT6 signaling pathway activity. Screen for activators or inhibitors of the STAT6 signaling pathway. Culture conditions: Cells should be grown at 37 degree C with 5% CO2 using RPMI medium supplemented with 10% heat-inactivated FBS, 1 mM sodium pyruvate, 10 mM HEPES and 1% Pen/Strep, plus 5 ng/ml mIL-3 (Note: mIL-3 is essential for Ba/F3 cell maintenance), plus 3 ug/ml of Puromycin. (Note: The parental Ba/F3-Puro cell line (Part #14135CCL) is a blank vector-transfected stable cell line which also requires 3 ug/ml of Puromycin for cell culture maintenance! Puromycin can be omitted during the reporter cell assays). It is recommended to quickly thaw the frozen cells upon receipt or from liquid nitrogen in a 37 degree C water-bath, transfer to a tube containing 10 ml of growth medium without Puromycin, spin down cells, resuspend cells in pre-warmed growth medium without Puromycin, transfer resuspended cells to T25 flask and culture in 37 degree C -CO2 incubator. Monitor the cell viability by counting cells daily for 1~3 days until cells completely recover viability as cells are doubling daily. Once cells are over 90% confluent, harvest cells by centrifugation and passage cells. At first passage, switch to growth medium containing Puromycin. Cells should be split before they reach complete confluence. To passage the cells, transfer cells to a tube, spin down cells, resuspend cells and seed appropriate aliquots of cell suspension into new culture vessels. Subcultivation ration = 1:10 to 1:20 weekly. To achieve satisfactory results, cells should not be passaged over 16 times. Functional validation: A. Response of STAT6 Leeporter - Ba/F3 cells to mIL-4. 1. Harvest STAT6 Leeporter - Ba/F3 cells and seed cells into a white solid-bottom 96-well microplate in 100 ul of growth medium without IL-3 at 1 x 10^5 cells/well. 2. Right after plating cells, stimulate cells with various concentrations of mouse IL-4 and incubate cells at 37 degree C in a CO2 incubator for 6-16 hours. 3. Add 50 ul of luciferase assay reagent per well. 4. Incubate at room temperature for 1-5 minutes and measure luminescence using a microplate luminometer. Researchers should empirically determine the suitability of the STAT6 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "STAT6, Cell Line" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.