Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only) ()

Total iron binding capacity Assay Kit

Total iron binding capacity assay kit (Colorimetric method)

Synonyms
Total iron binding capacity; Total iron binding capacity assay kit (Colorimetric method); Total iron binding capacity assay kit
Ordering
For Research Use Only!
Detection Range
0.03-50 mg/L
Intra-assay Precision
Take one kit to detect the samples of high concentration, middle concentration and low concentration respectively. The concentrations should be within the detection range. The samples of each concentration were tested 6 times (n=6) parallelly, and the average Intra-assay CV is 3.4%, which was calculated according to the following formula.
Inter-assay Precision
Take three kits of different batches to detect the samples of high concentration, middle concentration and low concentration respectively. The concentrations should be within the detection range. The samples of each concentration were tested 3 times (n=3) parallelly with each kit. Then calculate the corresponding values according to the following formula. The average Inter-assay CV is 4.7%.
Preparation and Storage
This kit is valid for up to 3 months. Please refer to the expiration date on the kit box.

Typical Testing Data/Standard Curve (for reference only)

()

Typical Testing Data/Standard Curve (for reference only) ()
Related Product Information for Total iron binding capacity assay kit
Intended Uses: This kit can be used to measure the total iron binding capacity (TIBC) content in serum samples. If you want to measure the unsaturated iron binding capacity (UIBC), the iron content of serum sample needs to be detected in addition (MBS2540518/ MBS2563956 are recommended).

Principle of the Assay: The excess iron is added to the serum to bind all the ferritin in the serum, and the excess iron is adsorbed by adding the iron adsorbent. The iron bind with the ferritin is separated from the protein by the action of acid solution and reductant. Fe3+ in serum is reduced to Fe2+, Fe2+ binds with bipyridine to form pink complex. In a certain range, the amount of TIBC is positively correlated with the depth of color. The iron content measured is, minus serum iron value, which is called unsaturated iron binding force. Total iron binding capacity minus serum iron value is unsaturated iron binding capacity (UIBC).

Background/Introduction: Total iron binding capacity (TIBC) was used as a parameter to evaluate the maximum capacity of serum iron transport. Iron is an essential biological element in organisms because it is involved in many metabolic processes such as oxygen transport, DNA synthesis and electronic transport. TIBC is also indirectly used to assess the level of serum transferrin.

Similar Products

Product Notes

The Total iron binding capacity (Catalog #AAA2540451) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Total iron binding capacity, Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.