Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Western Blot (WB) (Western Blot analysis of various cells using Vimentin Polyclonal Antibody at dilution of 1:1000.)

Epithelial-Mesenchymal Transition (EMT) Antibody Kit | EMT antibody kit

Epithelial-Mesenchymal Transition (EMT) Antibody Sampler Kit

Applications
Western Blot
Synonyms
Epithelial-Mesenchymal Transition (EMT); Epithelial-Mesenchymal Transition (EMT) Antibody Sampler Kit; EMT antibody kit
Ordering
For Research Use Only!
Applicable Applications for EMT antibody kit
Western Blot (WB)

Western Blot (WB)

(Western Blot analysis of various cells using Vimentin Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB) (Western Blot analysis of various cells using Vimentin Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB)

(Western Blot analysis of various cells using E-cadherin Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB) (Western Blot analysis of various cells using E-cadherin Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB)

(Western Blot analysis of various cells using N-cadherin Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB) (Western Blot analysis of various cells using N-cadherin Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB)

(Western Blot analysis of Hela cells using Claudin-1 Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB) (Western Blot analysis of Hela cells using Claudin-1 Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB)

(Western Blot analysis of 823 cells using Catenin-beta Polyclonal Antibody at dilution of 1:2000.)

Western Blot (WB) (Western Blot analysis of 823 cells using Catenin-beta Polyclonal Antibody at dilution of 1:2000.)

Western Blot (WB)

(Western Blot analysis of HepG2 cells using ZO-1 Monoclonal Antibody at dilution of 1:2000.)

Western Blot (WB) (Western Blot analysis of HepG2 cells using ZO-1 Monoclonal Antibody at dilution of 1:2000.)

Western Blot (WB)

(Western Blot analysis of 3T3 cells using SNAI 1 Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB) (Western Blot analysis of 3T3 cells using SNAI 1 Polyclonal Antibody at dilution of 1:1000.)

Western Blot (WB)

(Western Blot analysis of 1) MCF7, 2) Mouse heart, 3) Rat heart, 4) Rat brain with SLUG Polyclonal Antibody.)

Western Blot (WB) (Western Blot analysis of 1) MCF7, 2) Mouse heart, 3) Rat heart, 4) Rat brain with SLUG Polyclonal Antibody.)

Western Blot (WB)

(Western Blot analysis of HeLa cells using ZEB1 Monoclonal Antibody at dilution of 1:1000)

Western Blot (WB) (Western Blot analysis of HeLa cells using ZEB1 Monoclonal Antibody at dilution of 1:1000)
Related Product Information for EMT antibody kit
Background/Introduction: Epithelial-mesenchymal transition (EMT) is an essential process during development whereby epithelial cells aquire mesenchymal, fibroblast-like properties and display reduced intracellular adhesion and increased motility. This is a critical feature of normal embryonic development, which is also utilized by malignant epithelial tumors to spread beyond their origin. This tightly regulated process is associated with a number of cellular and molecular events. EMT depends on a reduction in expression of cell adhesion molecules. Cadherins mediate calcium-dependent cell-cell adhesion and play critical roles in normal tissue development. E-cadherin is considered an active suppressor of invasion and growth of many epithelial cancers. Recent studies indicate that cancer cells have up-regulated N-cadherin in addition to loss of Ecadherin. This change in cadherin expression is called the "cadherin switch" and downregulation of E-cadherin is one of the hallmarks of EMT. Tight junctions, or zonula occludens, form a continuous barrier to fluids across the epithelium and endothelium. They function in regulation of paracellular permeability and in the maintenance of cell polarity, blocking the movement of transmembrane proteins between the apical and the basolateral cell surfaces. Tight junctions are composed of claudin and occludin proteins, which join the junctions to the cytoskeleton. Zona occludens proteins ZO-1, 2, and 3 (also known as TJP 1, 2, and 3) are peripheral membrane adaptor proteins that link junctional transmembrane proteins such as occludin and claudin to the actin cytoskeleton. ZO-1 and -2 are required for tight junction formation and function; mutations in ZO-1 and Claudin induce EMT. Vimentin is an intermediate filament of mesenchymal origin and is present at early developmental stages. Vimentin's dynamic structural changes and spatial re-organization in response to extracellular stimuli helps to coordinate various signaling pathways. beta-catenin is a key downstream effector in the Wnt signaling pathway. It is implicated in two major biological processes in vertebrates: early embryonic development and tumorigenesis. beta-catenin also activates Slug. Slug (SNAI2) is a widely expressed transcriptional repressor and member of the Snail family of zinc finger transcription factors. Similar to the related Snail protein, Slug binds to the E-cadherin promoter region to repress transcription during development. The binding of Slug to integrin promoter sequences represses integrin expression and results in reduced cell adhesion. Down regulation of E-cadherin expression occurs during the EMT during embryonic development. ZEB family proteins are zinc finger and homeobox domain containing transcription factors. One of the targets suppressed by ZEB proteins is E-cadherin.

Similar Products

Product Notes

The EMT (Catalog #AAA2550105) is an Antibody Kit and is intended for research purposes only. The product is available for immediate purchase. AAA Biotech's Epithelial-Mesenchymal Transition (EMT) can be used in a range of immunoassay formats including, but not limited to, Western Blot (WB). Researchers should empirically determine the suitability of the EMT for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Epithelial-Mesenchymal Transition (EMT), Antibody Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.