Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Assay Kit DIY Support Pack 2 Support Pack

Assay Kit DIY Support Pack 2

Synonyms
Assay Kit DIY Support Pack 2; Assay Kit DIY Support Pack 2 support pack
Ordering
Components
Plate Sealer: 40 pieces; Coating Buffer: 1 bottles of powder; Blocking Buffer: 1 bottles of powder; Reagent Diluent 1: 1 bottles of powder; Reagent Diluent 2: 1 bottles of powder; Reagent Diluent 3: 1 bottles of powder; Wash Buffer: 2 bottles of powder; Enhancer: 1 tube of liquid
Component Notes
Plate Sealer: Use to cover the wells while incubation.
Coating Buffer: Used for coating antibody on the wells of 96-well strip plate. Prepare a working solution by diluting the Coating Buffer with deionized or distilled water before the experiment. 1 bottle can be used for preparing 220ml working solution.
Blocking Buffer: Used for blocking of unspecific binding sites of the plate. Prepare a working solution by diluting the Blocking Buffer with deionized or distilled water before the experiment. 1 bottle can be used for preparing 240ml working solution.
Reagent Diluent 1: Used for dilution of Standard. Prepare a working solution by diluting the reagent with deionized or distilled water before the experiment. 1 bottle can be used for preparing 160ml working solution.
Reagent Diluent 2: Used for dilution of Biontin-labeled Competitor. Prepare a working solution by diluting the reagent with deionized or distilled water before the experiment. 1 bottle can be used for preparing 120ml working solution.
Reagent Diluent 3: Used for dilution of Streptavidin-HRP. Prepare a working solution by diluting the reagent with deionized or distilled water before the experiment. 1 bottle can be used for preparing 120ml working solution.
Wash Buffer: For plate washing. Prepare a working solution by diluting the Wash Buffer with deionized or distilled water before the experiment. 1 bottle can be used for preparing 3200ml working solution.
Enhancer: Used to enhance the effect of blocking. Please add 50ul Enhancer into 100ml the Blocking Buffer working solution.
Preparation and Storage
This pack is valid for one year at room temperature. Please make all solutions fresh before the experiment.
Related Product Information for Assay Kit DIY Support Pack 2 support pack
The Assay Kit DIY Support Pack is intended to use together with Assay Kit DIY Materials for ELISA kit (competitive method) preparation. This pack provides sufficient materials and reagents for preparation of 10 Competitive ELISA/CLIA plates. All reagents should be used at room temperature and the pack is intended for research purposes only.

Similar Products

Product Notes

The Assay Kit DIY Support Pack 2 (Catalog #AAA2089472) is a Support Pack and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Assay Kit DIY Support Pack 2, Support Pack" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.