Typical Testing Data/Standard Curve (for reference only) (Fig.1. Mouse Microtubule-associated protein tau (MAPT) Standard Curve.)

Mouse Microtubule-Associated Protein tau (MAPT) ELISA Kit | MAPT elisa kit

Mouse Microtubule-Associated Protein tau (MAPT) ELISA Kit

Gene Names
MAPT; TAU; MSTD; PPND; DDPAC; MAPTL; MTBT1; MTBT2; FTDP-17; PPP1R103
Reactivity
Mouse
Synonyms
Microtubule-Associated Protein tau (MAPT); Mouse Microtubule-Associated Protein tau (MAPT) ELISA Kit; MAPT; DDPAC; FLJ31424; FTDP-17; MAPTL; MGC138549; MSTD; MTBT1; MTBT2; PPND; TAU; microtubule-associated protein tau; isoform 4; Tau Protein; G Protein Beta1/Gamma2 Subunit-Interacting Factor 1; MAPT elisa kit
Ordering
For Research Use Only!
Reactivity
Mouse
Specificity
Mouse Microtubule-associated protein tau (MAPT) ELISA Kit has high sensitivity and excellent specificity for detection of Mouse MAPT. No significant cross-reactivity or interference between Mouse MAPT and analogues was observed.
Sequence Length
383
Assay Type
Sandwich ELISA (Quantitative)
Samples
Cell Culture Supernatants, Serum, Plasma, Other Biological Fluids
Detection Method
Colorimetric
Usage Notes
* Do not mix components from different kit lots or use reagents beyond the kit expiration date.
* Allow all reagents to warm to room temperature for at least 30 minutes before opening.
* Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
* Unused wells must be kept desiccated at 4 degree C in the sealed bag provided.
* Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
* It is recommended that all samples and standards be assayed in duplicate or triplicate.
Preparation and Storage
Store at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

(Fig.1. Mouse Microtubule-associated protein tau (MAPT) Standard Curve.)

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Mouse Microtubule-associated protein tau (MAPT) Standard Curve.)
Related Product Information for MAPT elisa kit
Description: This Mouse Microtubule-associated protein tau (MAPT) ELISA Kit employs a two-site sandwich ELISA to quantitate MAPT in samples. An antibody specific for MAPT has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any MAPT present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MAPT is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MAPT bound in the initial step. The color development is stopped and the intensity of the color is measured.

Background: Tau protein is a highly soluble microtubule-associated protein (MAP). In humans, these proteins are mostly found in neurons compared to non-neuronal cells. One of tau's main functions is to modulate the stability of axonal microtubules. Tau is not present in dendrites and is active primarily in the distal portions of axons where it provides microtubule stabilization but also flexibility as needed. This contrasts with STOP proteins in the proximal portions of axons which essentially lock down the microtubules and MAP2 that stabilizes microtubules in dendrites. The tau gene locates on chromosome 17q21, containing 16 exons. The major tau protein in the human brain is encoded by 11 exons. Exon 2, 3 and 10 are alternative spliced, allowing six combinations (2-3-10-; 2+3-10-; 2+3+10-; 2-3-10+; 2+3-10+; 2+3+10+).

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Official Full Name
Microtubule-associated protein tau
NCBI Official Synonym Full Names
microtubule associated protein tau
NCBI Official Symbol
MAPT
NCBI Official Synonym Symbols
TAU; MSTD; PPND; DDPAC; MAPTL; MTBT1; MTBT2; FTDP-17; PPP1R103
NCBI Protein Information
microtubule-associated protein tau

NCBI Description

This gene encodes the microtubule-associated protein tau (MAPT) whose transcript undergoes complex, regulated alternative splicing, giving rise to several mRNA species. MAPT transcripts are differentially expressed in the nervous system, depending on stage of neuronal maturation and neuron type. MAPT gene mutations have been associated with several neurodegenerative disorders such as Alzheimer's disease, Pick's disease, frontotemporal dementia, cortico-basal degeneration and progressive supranuclear palsy. [provided by RefSeq, Jul 2008]

Research Articles on MAPT

Similar Products

Product Notes

The Mouse MAPT (Catalog #AAA9717731) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA9717731 ELISA Kit recognizes Mouse MAPT. It is sometimes possible for the material contained within the vial of "Microtubule-Associated Protein tau (MAPT), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.