Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Flow Cytometry (FC/FACS) (Flow cytometry analysis (surface staining) of human peripheral blood with anti-STRO-1 (STRO-1) APC.)

Mouse STRO-1 Monoclonal Antibody | anti-STRO-1 antibody

Anti-Hu STRO-1 APC

Reactivity
Human, Rabbit, Rat
Applications
Flow Cytometry, Functional Assay
Purity
The purified antibody is conjugated with allophycocyanin (APC) under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Synonyms
STRO-1; Monoclonal Antibody; Anti-Hu STRO-1 APC; STRO1; anti-STRO-1 antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human, Rabbit, Rat
Clonality
Monoclonal
Isotype
IgM lambda
Clone Number
STRO-1
Specificity
The mouse monoclonal antibody STRO-1 recognizes an extracellular epitope of the cell surface antigen STRO-1 expressed by bone marrow mesenchymal stromal cells and nucleated erythroid precursors, but not by committed hematopoietic progenitors.
Purity/Purification
The purified antibody is conjugated with allophycocyanin (APC) under optimum conditions. The conjugate is purified by size-exclusion chromatography.
Form/Format
Stabilizing Tris buffered saline (TBS) solution with 15 mM sodium azide
Concentration
0.1 mg/ml (varies by lot)
Applicable Applications for anti-STRO-1 antibody
Flow Cytometry (FC/FACS)
Application Notes
FC/FACS: QC tested
Immunogen
Human CD34 positive bone marrow cells
Conjugation
APC
Preparation and Storage
Store in the dark at 2-8 degree C. Do not freeze. Avoid prolonged exposure to light.

Flow Cytometry (FC/FACS)

(Flow cytometry analysis (surface staining) of human peripheral blood with anti-STRO-1 (STRO-1) APC.)

Flow Cytometry (FC/FACS) (Flow cytometry analysis (surface staining) of human peripheral blood with anti-STRO-1 (STRO-1) APC.)
Related Product Information for anti-STRO-1 antibody
STRO-1 is a cell surface antigen expressed by stromal elements in human bone marrow, identified by monoclonal antibody STRO-1. Approximately 10% of mononuclear cells, greater than 95% of which are nucleated erythroid precursors, are STRO-1 positive, whereas the CFU-GM (colony-forming unit granulocyte-macrophage), BFU-E (erythroid burst) and CFU-Mix (mixed colonies) committed progenitor cells are negative. CFU-F (fibroblast colony-forming cells) are present exclusively in the STRO-1 positive population. When plated under long-term bone marrow culture conditions, STRO-1 positive cells generate adherent cell layers containing multiple stromal cell types, including adipocytes, smooth muscle cells, osteoblasts, chondrocytes, and fibroblastic elements. In combination with glycophorin A, STRO-1 is a useful marker for identification of mesenchymal stem cells. STRO-1 and CD117 are markers for osteosarcoma cells.

Similar Products

Product Notes

The STRO-1 (Catalog #AAA1801558) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The Anti-Hu STRO-1 APC reacts with Human, Rabbit, Rat and may cross-react with other species as described in the data sheet. AAA Biotech's STRO-1 can be used in a range of immunoassay formats including, but not limited to, Flow Cytometry (FC/FACS). FC/FACS: QC tested. Researchers should empirically determine the suitability of the STRO-1 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "STRO-1, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.