Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Mouse anti-Human OATP2 Monoclonal Antibody | anti-SLCO1B1 antibody

OATP2 (Organic Anion Transporting Polypeptide 2)

Gene Names
SLCO1B1; LST1; LST-1; OATP2; OATPC; OATP-C; OATP1B1; SLC21A6; MGC133282
Reactivity
Human
Applications
Western Blot, Immunoprecipitation, Immunohistochemistry, Immunofluorescence
Purity
Supernatant
Synonyms
OATP2; Monoclonal Antibody; OATP2 (Organic Anion Transporting Polypeptide 2); Anti -OATP2 (Organic Anion Transporting Polypeptide 2); anti-SLCO1B1 antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human
Clonality
Monoclonal
Isotype
IgM
Clone Number
5F253
Specificity
Recognizes human OATP2 at ~90kD. Using immunofluorescence microscopy this antibody stains the sinusoidal (basolateral) membranes in frozen sections of human liver, hepatocellular carcinoma and the human cell line HEK293 transfected with SLC21A6.
Purity/Purification
Supernatant
Form/Format
Supplied as a liquid, 0.09% sodium azide.
Applicable Applications for anti-SLCO1B1 antibody
Western Blot (WB), Immunoprecipitation (IP), Immunohistochemistry (IHC), Immunofluorescence (IF)
Application Notes
Western Blot: Boiling sample before SDS-PAGE is notrecommended. Samples should be kept at 37ºC for 30 min.
Immunohistochemistry (Frozen): Neat; Suggested incubationtime: 1 hr at RT.
Optimal dilutions to be determined by the researcher.
Immunogen
Synthetic peptide corresponding to the C-terminus (21aa) of human organic anion transporter SLC21A6 (KLH).
Grade
Supernatant
Positive Control
SCL21A6 transfected HEK293 cells
Negative Control
HepG2 and PLC cells
Preparation and Storage
May be stored at 4 degree C for short-term only. Aliquot to avoid repeated freezing and thawing. Store at -20 degree C. Aliquots are stable for 12 months. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap.
Related Product Information for anti-SLCO1B1 antibody
According to recent nomenclature this hepatocyte-specific protein is identical to OATP1B1 (2) also known as OATP-C.
Product Categories/Family for anti-SLCO1B1 antibody

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
UniProt Accession #
NCBI Official Full Name
organic anion transport polypeptide 2
NCBI Official Synonym Full Names
solute carrier organic anion transporter family, member 1B1
NCBI Official Symbol
SLCO1B1
NCBI Official Synonym Symbols
LST1; LST-1; OATP2; OATPC; OATP-C; OATP1B1; SLC21A6; MGC133282
NCBI Protein Information
solute carrier organic anion transporter family member 1B1; OATP-2; OTTHUMP00000239999; solute carrier family 21 member 6; liver-specific organic anion transporter 1; sodium-independent organic anion-transporting polypeptide 2; solute carrier family 21 (organic anion transporter), member 6
UniProt Protein Name
Solute carrier organic anion transporter family member 1B1
UniProt Gene Name
SLCO1B1
UniProt Synonym Gene Names
LST1; OATP1B1; OATP2; OATPC; SLC21A6
UniProt Entry Name
SO1B1_HUMAN

NCBI Description

This gene encodes a liver-specific member of the organic anion transporter family. The encoded protein is a transmembrane receptor that mediates the sodium-independent uptake of numerous endogenous compounds including bilirubin, 17-beta-glucuronosyl estradiol and leukotriene C4. This protein is also involved in the removal of drug compounds such as statins, bromosulfophthalein and rifampin from the blood into the hepatocytes. Polymorphisms in the gene encoding this protein are associated with impaired transporter function. [provided by RefSeq]

Uniprot Description

SLCO1B1: Mediates the Na(+)-independent uptake of organic anions such as pravastatin, taurocholate, methotrexate, dehydroepiandrosterone sulfate, 17-beta-glucuronosyl estradiol, estrone sulfate, prostaglandin E2, thromboxane B2, leukotriene C3, leukotriene E4, thyroxine and triiodothyronine. Involved in the clearance of bile acids and organic anions from the liver. Defects in SLCO1B1 are a cause of hyperbilirubinemia, Rotor type (HBLRR). An autosomal recessive form of primary conjugated hyperbilirubinemia. Affected individuals develop mild jaundice not associated with hemolysis shortly after birth or in childhood. They have delayed plasma clearance of the unconjugated anionic dye bromsulphthalein and prominent urinary excretion of coproporphyrin I. Hepatic pigmentation is normal. Belongs to the organo anion transporter (TC 2.A.60) family.

Protein type: Transporter; Transporter, SLC family; Membrane protein, multi-pass; Membrane protein, integral

Chromosomal Location of Human Ortholog: 12p

Cellular Component: membrane; basolateral plasma membrane; integral to plasma membrane; plasma membrane

Molecular Function: sodium-independent organic anion transmembrane transporter activity

Biological Process: bile acid and bile salt transport; sodium-independent organic anion transport; bile acid metabolic process; transmembrane transport; organic anion transport

Disease: Hyperbilirubinemia, Rotor Type

Research Articles on SLCO1B1

Similar Products

Product Notes

The SLCO1B1 slco1b1 (Catalog #AAA601552) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The OATP2 (Organic Anion Transporting Polypeptide 2) reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's OATP2 can be used in a range of immunoassay formats including, but not limited to, Western Blot (WB), Immunoprecipitation (IP), Immunohistochemistry (IHC), Immunofluorescence (IF). Western Blot: Boiling sample before SDS-PAGE is notrecommended. Samples should be kept at 37ºC for 30 min. Immunohistochemistry (Frozen): Neat; Suggested incubationtime: 1 hr at RT. Optimal dilutions to be determined by the researcher. Researchers should empirically determine the suitability of the SLCO1B1 slco1b1 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "OATP2, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.