Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Angiotensin II Receptor 1 (AGTR1) ELISA Kit | AGTR1 elisa kit

Human Angiotensin II Receptor 1 (AGTR1) ELISA Kit

Gene Names
AGTR1; AT1; AG2S; AT1B; AT1R; AT1AR; AT1BR; AT2R1; HAT1R; AGTR1B
Reactivity
Human
Synonyms
Angiotensin II Receptor 1 (AGTR1); Human Angiotensin II Receptor 1 (AGTR1) ELISA Kit; AT1R; AG2S; AG2-S; AGTR1A; AGTR1B; AT1; AT1B; AT2R1; AT2-R1; AT2R1A; AT2R1B; HAT1R; AT1 Receptor; Angiotensin Receptor 1B; AGTR1 elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of Angiotensin II Receptor 1 (AGTR1).
No significant cross-reactivity or interference between Angiotensin II Receptor 1 (AGTR1) and analogues was observed.
Sequence Length
359
Assay Type
Double-antibody Sandwich
Samples
Tissue homogenates, Cell lysates and Other Biological Fluids
Detection Range
0.156-10ng/mL
Sensitivity
< 0.055ng/mL
Application
Enzyme-linked immunosorbent assay for Antigen Detection.
Intra-assay Precision (Precision within an assay)
3 samples with low, middle and high level Angiotensin II Receptor 1 (AGTR1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays)
3 samples with low, middle and high level Angiotensin II Receptor 1 (AGTR1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) =
SD/meanX100
Intra-Assay
CV<10%
Inter-Assay
CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for AGTR1 elisa kit
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Angiotensin II Receptor 1 (AGTR1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Angiotensin II Receptor 1 (AGTR1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Angiotensin II Receptor 1 (AGTR1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Angiotensin II Receptor 1 (AGTR1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
185
UniProt Accession #
Molecular Weight
41,061 Da
NCBI Official Full Name
angiotensin II receptor variant 1
NCBI Official Synonym Full Names
angiotensin II receptor, type 1
NCBI Official Symbol
AGTR1
NCBI Official Synonym Symbols
AT1; AG2S; AT1B; AT1R; AT1AR; AT1BR; AT2R1; HAT1R; AGTR1B
NCBI Protein Information
type-1 angiotensin II receptor
UniProt Protein Name
Type-1 angiotensin II receptor
UniProt Gene Name
AGTR1
UniProt Synonym Gene Names
AGTR1A; AGTR1B; AT2R1; AT2R1B; AT1
UniProt Entry Name
AGTR1_HUMAN

NCBI Description

Angiotensin II is a potent vasopressor hormone and a primary regulator of aldosterone secretion. It is an important effector controlling blood pressure and volume in the cardiovascular system. It acts through at least two types of receptors. This gene encodes the type 1 receptor which is thought to mediate the major cardiovascular effects of angiotensin II. This gene may play a role in the generation of reperfusion arrhythmias following restoration of blood flow to ischemic or infarcted myocardium. It was previously thought that a related gene, denoted as AGTR1B, existed; however, it is now believed that there is only one type 1 receptor gene in humans. Multiple alternatively spliced transcript variants have been reported for this gene. [provided by RefSeq, Jul 2012]

Uniprot Description

AT1: receptor for angiotensin II. Angiotensin II is a potent vasopressor hormone and a primary regulator of aldosterone secretion. It is an important effector controlling blood pressure and volume in the cardiovascular system. Mediates the major cardiovascular effects of angiotensin II. May play role in the generation of reperfusion arrhythmias following restoration of blood flow to ischemic or infarcted myocardium. Mediates its action by association with G proteins that activate a phosphatidylinositol-calcium second messenger system.

Protein type: GPCR, family 1; Membrane protein, multi-pass; Receptor, GPCR; Membrane protein, integral

Chromosomal Location of Human Ortholog: 3q24

Cellular Component: integral to plasma membrane; integral to membrane; plasma membrane

Molecular Function: protein binding; angiotensin type II receptor activity; protein heterodimerization activity; angiotensin type I receptor activity; bradykinin receptor binding

Biological Process: elevation of cytosolic calcium ion concentration during G-protein signaling, coupled to IP3 second messenger (phospholipase C activating); regulation of vasodilation; positive regulation of cellular protein metabolic process; renin-angiotensin regulation of aldosterone production; calcium-mediated signaling; regulation of systemic arterial blood pressure by renin-angiotensin; Rho protein signal transduction; regulation of cell proliferation; G-protein coupled receptor protein signaling pathway; elevation of cytosolic calcium ion concentration; renin-angiotensin regulation of blood vessel size; regulation of vasoconstriction; regulation of inflammatory response; G-protein signaling, coupled to IP3 second messenger (phospholipase C activating); regulation of cell growth; kidney development; positive regulation of phospholipase A2 activity; positive regulation of inflammatory response; positive regulation of NAD(P)H oxidase activity

Disease: Renal Tubular Dysgenesis; Hypertension, Essential

Research Articles on AGTR1

Similar Products

Product Notes

The Human AGTR1 agtr1 (Catalog #AAA2021112) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2021112 ELISA Kit recognizes Human AGTR1. It is sometimes possible for the material contained within the vial of "Angiotensin II Receptor 1 (AGTR1), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.