Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Albumin (ALB) CLIA Kit | ALB clia kit

Human Albumin (ALB) CLIA Kit

Gene Names
ALB; HSA; PRO0883; PRO0903; PRO1341
Reactivity
Human
Applications
Chemiluminescence Immunoassay (CLIA)
Synonyms
Albumin (ALB); Human Albumin (ALB) CLIA Kit; Albumin; Serum albumin; ALB clia kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of Albumin (ALB).
No significant cross-reactivity or interference between Albumin (ALB) and analogues was observed.
Sequence Length
609
Applicable Applications for ALB clia kit
Chemiluminescence Immunoassay (CLIA)
Assay Type
Competitive Inhibition
Samples
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
1.56-400ug/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.52ug/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Albumin (ALB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Albumin (ALB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Test Principle
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Albumin (ALB). A competitive inhibition reaction is launched between biotin labeled Albumin (ALB) and unlabeled Albumin (ALB) (Standards or samples) with the pre-coated antibody specific to Albumin (ALB). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Albumin (ALB) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Albumin (ALB) level in the sample or standard.
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
213
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
NCBI Official Full Name
serum albumin preproprotein
NCBI Official Synonym Full Names
albumin
NCBI Official Symbol
ALB
NCBI Official Synonym Symbols
HSA; PRO0883; PRO0903; PRO1341
NCBI Protein Information
serum albumin
UniProt Protein Name
Serum albumin
Protein Family
UniProt Gene Name
ALB
UniProt Entry Name
ALBU_HUMAN

NCBI Description

This gene encodes the most abundant protein in human blood. This protein functions in the regulation of blood plasma colloid osmotic pressure and acts as a carrier protein for a wide range of endogenous molecules including hormones, fatty acids, and metabolites, as well as exogenous drugs. Additionally, this protein exhibits an esterase-like activity with broad substrate specificity. The encoded preproprotein is proteolytically processed to generate the mature protein. A peptide derived from this protein, EPI-X4, is an endogenous inhibitor of the CXCR4 chemokine receptor. [provided by RefSeq, Jul 2016]

Uniprot Description

albumin: Serum albumin, the main protein of plasma, has a good binding capacity for water, Ca(2+), Na(+), K(+), fatty acids, hormones, bilirubin and drugs. Its main function is the regulation of the colloidal osmotic pressure of blood. Major zinc transporter in plasma, typically binds about 80% of all plasma zinc. Plasma. Belongs to the ALB/AFP/VDB family. 2 isoforms of the human protein are produced by alternative splicing.

Protein type: Secreted, signal peptide; Carrier; Secreted

Chromosomal Location of Human Ortholog: 4q13.3

Cellular Component: extracellular space; protein complex; extracellular region; basement membrane; nucleus

Molecular Function: antioxidant activity; toxin binding; protein binding; copper ion binding; enzyme binding; DNA binding; zinc ion binding; chaperone binding; drug binding; oxygen binding; fatty acid binding; pyridoxal phosphate binding

Biological Process: platelet activation; receptor-mediated endocytosis; sodium-independent organic anion transport; bile acid metabolic process; maintenance of mitochondrion localization; lipoprotein metabolic process; hemolysis by symbiont of host red blood cells; cellular response to starvation; response to organic substance; response to mercury ion; bile acid and bile salt transport; retinal homeostasis; platelet degranulation; transport; negative regulation of programmed cell death; blood coagulation; transmembrane transport; positive regulation of circadian sleep/wake cycle, non-REM sleep; response to nutrient; negative regulation of apoptosis

Disease: Analbuminemia; Hyperthyroxinemia, Familial Dysalbuminemic

Research Articles on ALB

Similar Products

Product Notes

The Human ALB alb (Catalog #AAA2707946) is a CLIA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2707946 CLIA Kit recognizes Human ALB. AAA Biotech's Albumin (ALB) can be used in a range of immunoassay formats including, but not limited to, Chemiluminescence Immunoassay (CLIA). Researchers should empirically determine the suitability of the ALB alb for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Albumin (ALB), CLIA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.