Structure (Structure of T3002.)

3,6,9,12-Tetraoxatetradecane-1,14-diyl-bis-methanethiosulfonate Biochemical

3,6,9,12-Tetraoxatetradecane-1,14-diyl-bis-methanethiosulfonate (MTS-14-04-MTS)

Purity
~90%
Synonyms
3; 6; 9; 12-Tetraoxatetradecane-1; 14-diyl-bis-methanethiosulfonate; 14-diyl-bis-methanethiosulfonate (MTS-14-04-MTS); 14-diyl-bis-methanethiosulfonate biochemical
Ordering
For Research Use Only!
Purity/Purification
~90%
CAS Number
212262-08-3
Molecular Formula
C12H26O8S4
Atmosphere
Inert gas
Method for Determining Identity
Proton NMR (CDCl3) Spectroscopic and Mass Spectrometric Analysis
Solubility
Chloroform
TLC Conditions
SiO2; Ethyl Acetate=100%; Visualized with AMCS and KMnO4; Single spot, Rf=0.3.
Toxicity and Hazards
Due to the potential danger associated with the use of some of MyBioSource biochemicals, all products should be handled by qualified personnel only, trained in laboratory procedures, and familiar with potential hazards. Information is not available on the possible hazards of many experimental compounds. The absence of a warning must not be interpreted as indication of safety. The ultimate responsibility for the proper handling of any and all chemicals lies with the user. All goods sold by MyBioSource carry the condition that liability for any injury, loss or damage whatsoever to persons or real property resulting from the handling of the said goods lies with the user. Acceptance of our goods binds the customer to these terms.
Preparation and Storage
May be stored at RT for short-term only. Long-term storage is recommended at 4 degree C. For maximum recovery of product, centrifuge the original vial prior to removing the cap. Store under inert conditions. Moisture sensitive.
At pH 7.5 and room temperature, MTSEA hydrolyzes with a half-life of about 15 minutes, MTSET hydrolyzes with a half-life of 10 minutes, and MTSES hydrolyzes with a half-life of 20 minutes. Routinely, one can use 2.5mM MTSEA, 1mM MTSET, or 10mM MTSES, applied for 1 to 5 minutes. (MTSET is 2.5 times as reactive with small sulfhydryl compounds as is MTSEA, and 10 times as reactive as MTSES). (Stauffer and Karlin, 1994; Karlin, personal communication).
For application to Xenopus Oocytes, dissolve the compounds in 115mM NaCl, 2.5mM KCl, 1.8mM MgCl2, 10mM Hepes, pH 7.5 with NaOH. MTS reagents decompose in buffer very quickly.
•DMSO is a good solvent for the MTS reagents which are not water soluble (i.e. the non-charged MTS reagents).

Structure

(Structure of T3002.)

Structure (Structure of T3002.)
Related Product Information for 3,6,9,12-Tetraoxatetradecane-1,14-diyl-bis-methanethiosulfonate biochemical
A sulfhydryl cross-linking reagent.
Product Categories/Family for 3,6,9,12-Tetraoxatetradecane-1,14-diyl-bis-methanethiosulfonate biochemical

Similar Products

Product Notes

The 3,6,9,12-Tetraoxatetradecane-1,14-diyl-bis-methanethiosulfonate (Catalog #AAA6064868) is a Biochemical and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "3,6,9,12-Tetraoxatetradecane-1,14-diyl-bis-methanethiosulfonate, Biochemical" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.