Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Testing Data

Radius 24-Well Cell Migration Assay, (ECM Array Coated) Assay Kit

Radius 24-Well Cell Migration Assay, (ECM Array Coated)

Synonyms
Radius 24-Well Cell Migration Assay; (ECM Array Coated); (ECM Array Coated) assay kit
Ordering
For Research Use Only!
Preparation and Storage
Upon receipt, aliquot and store the Radius Gel Removal Solution and DAPI Fluorescence Stain at -20 degree C (avoid multiple freeze/thaw cycles), and transfer the Fixation Solution to 4 degree C. All other kit components should be stored at room temperature until the kit's expiration date.

Testing Data

Testing Data

Testing Data #2

Testing Data #2

Testing Data #3

Testing Data #3

Testing Data #4

Testing Data #4
Related Product Information for Radius 24-Well Cell Migration Assay, (ECM Array Coated) assay kit
Background: Cell migration is a highly integrated, multistep process that orchestrates embryonic morphogenesis, tissue repair and regeneration. It plays a pivotal role in the disease progression of cancer, mental retardation, atherosclerosis, and arthritis. The initial response of a cell to a migration-promoting agent is to polarize and extend protrusions in the direction of the attractant; these protrusions can consist of large, broad lamellipodia or spike-like filopodia. In either case, these protrusions are driven by actin polymerization and can be stabilized by extracellular matrix (ECM) adhesion or cell-cell interactions (via transmembrane receptors). The Radius Cell Migration Assay Kit utilizes a proprietary 24-well plate, which has been pre-coated with various ECM proteins (see Migration Plate Layout below), to monitor the migratory properties of cells. Each plate well contains a 0.68 mm non-toxic, biocompatible hydrogel spot (Radius Gel) where cells cannot attach. When adherent cells are seeded in the Radius Cell Migration well, they attach outside of the Radius Gel coated area. Once firm cell attachment is achieved, the hydrogel is quickly removed to expose a cell-free region to study cell migration/closure. This format provides a robust in vitro system to measure 2-D cell migration, screen potential inhibitors and study cytoskeleton reorganization events. The Radius Cell Migration Assay Kit is designed for High Content Analysis applications or imaging software and is adaptable to liquid handling equipment. Each kit provides sufficient quantities to perform 24 migration tests (18 ECM protein-coated wells, 6 uncoated wells).
Product Categories/Family for Radius 24-Well Cell Migration Assay, (ECM Array Coated) assay kit
References
1. Ridley AJ, Schwartz MA, Burridge K, Firtel RA, Ginsberg MH, Borisy G, Parsons JT, Horwitz AR. (2003) Science 302, 1704-9.
2. Horwitz R, Webb D. (2003) Curr Biol. 13, R756-9.
3. Lauffenburger DA, Horwitz AF. (1996) Cell 84, 359-369.

Similar Products

Product Notes

The Radius 24-Well Cell Migration Assay, (ECM Array Coated) (Catalog #AAA169144) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Radius 24-Well Cell Migration Assay, (ECM Array Coated), Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.