Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Testing Data (Fig. Economical Cell Counting Kit-8 (CCK-8) is designed to detect cell proliferation and cell toxicity.)

Cell Counting 8 (CCK-8) Assay Kit | CCK-8 assay kit

Cell Counting Kit-8 (CCK-8)

Synonyms
Cell Counting 8 (CCK-8); Cell Counting Kit-8 (CCK-8); CCK-8; WST-8; CCK8; WST8; CCK-8 assay kit
Ordering
For Research Use Only!
Form/Format
Liquid solution
Kit Components
CCK-8 solution
Features & Benefits
One-bottle, ready-to-use solution.
The product (formazan) produced by WST-8 is water soluble, No organic solvents or isotopes required. And the formazan is stable and safe.
The detection sensitivity using CCK-8 is higher than assays using other tetrazolium salts such as MTT, XTT, MTS or WST-1.
The same cells can be used for other cell assays because of the low toxicity of CCK-8.
Usage Notes
Since the CCK-8 assay is based on the dehydrogenase activity detection in viable cells, conditions or chemicals that affect dehydrogenase activity in viable cells may cause discrepancy between the actual viable cell number and the cell number determined using the CCK-8 assay.
Be careful not to introduce bubbles to the wells, since they interfere with the OD reading.
The incubation time varies by the type and number of cells in a well. Generally, leukocytes give weak coloration, thus a long incubation time (up to 4 hours) or a large number of cells (~105 cells/well) may be necessary.
If the color or PH of culture media is changed due to long-time culture, please change the culture media when adding CCK-8.
The same cells can be used for other cell assays because of the low toxicity of CCK-8.
Preparation and Storage
CCK-8 is stable for one year at 0-5 degree C with protection from light. Store it at -20 degree C for longer storage. Repeated thawing and freezing causes an increase in the background, which interferes with the assay. Please store the kit at 0-5 degree C for frequent use.
Shipping: Gel pack with blue ice.

Testing Data

(Fig. Economical Cell Counting Kit-8 (CCK-8) is designed to detect cell proliferation and cell toxicity.)

Testing Data (Fig. Economical Cell Counting Kit-8 (CCK-8) is designed to detect cell proliferation and cell toxicity.)
Related Product Information for CCK-8 assay kit
Cell Counting Kit-8 (CCK-8) is designed for detecting Cell Proliferation and Cytotoxicity
Background: Cell Counting Kit-8 (CCK-8) allows very convenient assays by utilizing highly water-soluble tetrazolium salt-WST-8.[2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium, monosodium salt] produces a water-soluble formazan dye upon reduction in the presence of an electron mediator. CCK-8, being nonradioactive, allows sensitive colorimetric assays for the determination of the number of viable cells in cell proliferation and cytotoxicity assays. WST-8 is reduced by dehydrogenases in cells to give an orange colored product (formazan), which is soluble in the tissue culture medium. The amount of the formazan dye generated by dehydrogenases in cells is directly proportional to the number of living cells. The product (formazan) produced by WST-8 is water soluble, no organic solvents or isotopes required. And the formazan is stable and safe. The detection sensitivity using CCK-8 is higher than assays using other tetrazolium salts such as MTT, XTT, MTS or WST-1.
Product Categories/Family for CCK-8 assay kit

Similar Products

Product Notes

The CCK-8 (Catalog #AAA9719068) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Cell Counting 8 (CCK-8), Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.