Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Myosin-X (MYO10) Standard Curve.)

Human Myosin-X (MYO10) ELISA Kit | MYO10 elisa kit

Human Myosin-X (MYO10) ELISA Kit

Reactivity
Human
Synonyms
Myosin-X (MYO10); Human Myosin-X (MYO10) ELISA Kit; MYO10; FLJ10639; FLJ21066; FLJ22268; FLJ43256; KIAA0799; MGC131988; MYO10 elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
Human Myosin-X (MYO10) ELISA Kit has high sensitivity and excellent specificity for detection of Human MYO10. No significant cross-reactivity or interference between Human MYO10 and analogues was observed.
Sequence Length
2058
Assay Type
Sandwich ELISA (Quantitative)
Samples
Cell Culture Supernatants, Serum, Plasma, Other Biological Fluids
Detection Method
Colorimetric
Usage Notes
* Do not mix components from different kit lots or use reagents beyond the kit expiration date.
* Allow all reagents to warm to room temperature for at least 30 minutes before opening.
* Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
* Unused wells must be kept desiccated at 4 degree C in the sealed bag provided.
* Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
* It is recommended that all samples and standards be assayed in duplicate or triplicate.
Preparation and Storage
Store at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

(Fig.1. Human Myosin-X (MYO10) Standard Curve.)

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Myosin-X (MYO10) Standard Curve.)
Related Product Information for MYO10 elisa kit
Description: This Human Myosin-X (MYO10) ELISA Kit employs a two-site sandwich ELISA to quantitate MYO10 in samples. An antibody specific for MYO10 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any MYO10 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MYO10 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MYO10 bound in the initial step. The color development is stopped and the intensity of the color is measured.

Background: MYO10 encodes a member of the myosin superfamily. Myosin-X represents an unconventional myosin; it should not be confused with the conventional non-muscle myosin-10 (MYH10). Unconventional myosins contain the basic domains of conventional myosins and are further distinguished from class members by their tail domains. MYO10 functions as an actin-based molecular motor and plays a role in integration of F-actin and microtubule cytoskeletons during meiosis.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
NCBI Official Full Name
unconventional myosin-X
NCBI Official Synonym Full Names
myosin X
NCBI Official Symbol
MYO10
NCBI Protein Information
unconventional myosin-X
UniProt Protein Name
Unconventional myosin-X
Protein Family
UniProt Gene Name
MYO10
UniProt Synonym Gene Names
KIAA0799
UniProt Entry Name
MYO10_HUMAN

NCBI Description

This gene encodes a member of the myosin superfamily. The protein represents an unconventional myosin; it should not be confused with the conventional non-muscle myosin-10 (MYH10). Unconventional myosins contain the basic domains of conventional myosins and are further distinguished from class members by their tail domains. This gene functions as an actin-based molecular motor and plays a role in integration of F-actin and microtubule cytoskeletons during meiosis. [provided by RefSeq, Dec 2011]

Uniprot Description

MYO10: Myosins are actin-based motor molecules with ATPase activity. Unconventional myosins serve in intracellular movements. MYO10 binds to actin filaments and actin bundles and functions as plus end-directed motor. The tail domain binds to membranous compartments containing phosphatidylinositol 3,4,5-trisphosphate or integrins, and mediates cargo transport along actin filaments. Regulates cell shape, cell spreading and cell adhesion. Stimulates the formation and elongation of filopodia. May play a role in neurite outgrowth and axon guidance. Plays a role in formation of the podosome belt in osteoclasts.

Protein type: Motor; Motility/polarity/chemotaxis

Chromosomal Location of Human Ortholog: 5p15.1-p14.3

Cellular Component: ruffle; filopodium membrane; filopodium tip; neuron projection; cell soma; lamellipodium; cytoplasm; nucleolus; plasma membrane; cell cortex; cytosol; myosin complex

Molecular Function: actin filament binding; calmodulin binding; protein binding; phosphatidylinositol-3,4,5-triphosphate binding; spectrin binding; plus-end directed microfilament motor activity; actin-dependent ATPase activity; ATP binding

Biological Process: axon guidance; regulation of cell shape; metabolic process; positive regulation of cell-cell adhesion; innate immune response; regulation of filopodium formation; cytoskeleton-dependent intracellular transport

Research Articles on MYO10

Similar Products

Product Notes

The Human MYO10 myo10 (Catalog #AAA9715097) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA9715097 ELISA Kit recognizes Human MYO10. It is sometimes possible for the material contained within the vial of "Myosin-X (MYO10), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.