Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Rat Troponin T Type 2, Cardiac (TNNT2) ELISA Kit | TNNT2 elisa kit

Rat Troponin T Type 2, Cardiac (TNNT2) ELISA Kit

Gene Names
Tnnt2; Ctt; CTTG; Tnnt3; RATCTTG
Reactivity
Rat
Synonyms
Troponin T Type 2; Cardiac (TNNT2); Rat Troponin T Type 2; Cardiac (TNNT2) ELISA Kit; CMH2; cTnT; TnTc; Cardiomyopathy; Hypertrophic 2; Cardiac muscle troponin T; TNNT2 elisa kit
Ordering
For Research Use Only!
Reactivity
Rat
Specificity
This assay has high sensitivity and excellent specificity for detection of TNNT2. No significant cross-reactivity or interference between TNNT2 and analogues was observed.
Sequence Length
289
Samples
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Type
Sandwich
Detection Range
15.625-1000pg/mL
Sensitivity
5.4pg/mL
Intra-assay Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level TNNT2 were tested 20 times on one plate, respectively. Intra-Assay: CV<10%
Inter-assay Precision
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level TNNT2 were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Inter-Assay: CV<12%
Preparation and Storage
For unopened kit, all reagents should be kept according to the labels on vials. The TMB Substrate, Wash Buffer, Stop Solution should be stored at 4 degree C. All others should be stored at -20 degree C.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for TNNT2 elisa kit
Intended Uses: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of TNNT2 in rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Principle of the Assay: The microtiter plate provided in this kit has been pre-coated with an antibody specific to TNNT2. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to TNNT2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain TNNT2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of TNNT2 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
34,452 Da
NCBI Official Full Name
troponin T, cardiac muscle isoform X9
NCBI Official Synonym Full Names
troponin T2, cardiac type
NCBI Official Symbol
Tnnt2
NCBI Official Synonym Symbols
Ctt; CTTG; Tnnt3; RATCTTG
NCBI Protein Information
troponin T, cardiac muscle
UniProt Protein Name
Cardiac troponin T2
Protein Family
UniProt Gene Name
Tnnt2

NCBI Description

tropomyosin-binding subunit of troponin; confers calcium-sensitivy to actinomysin ATPase activity in striated muscle [RGD, Feb 2006]

Research Articles on TNNT2

Similar Products

Product Notes

The Rat TNNT2 tnnt2 (Catalog #AAA453962) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA453962 ELISA Kit recognizes Rat TNNT2. It is sometimes possible for the material contained within the vial of "Troponin T Type 2, Cardiac (TNNT2), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.