Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Rat FXII (Coagulation Factor XII) CLIA Kit | FXII clia kit

Rat FXII (Coagulation Factor XII) CLIA Kit

Gene Names
F12; HAF; HAE3; HAEX
Reactivity
Rat
Synonyms
FXII (Coagulation Factor XII); Rat FXII (Coagulation Factor XII) CLIA Kit; FXII clia kit
Ordering
For Research Use Only!
Reactivity
Rat
Specificity
This kit recognizes natural and recombinant FXII. No significant cross-reactivity or interference between FXII and analogues was observed.
Sequence Length
612
Assay Type
Sandwich
Detection Range
125-8000pg/mL
Sensitivity
Min: 75pg/mL; Max: 8000pg/mL

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for FXII clia kit
Intended Uses: This CLIA kit applies to the in vitro quantitative determination of FXII concentrations in serum, plasma and other biological fluids.

Principle of the Assay: This kit uses Sandwich-CLIA as the method. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to FXII. Standards or samples are added to the appropriate micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for FXII and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain FXII, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured spectrophotometrically by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of FXII. You can calculate the concentration of FXII in the samples by comparing the RLU value of the samples to the standard curve.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
Molecular Weight
67,792 Da
NCBI Official Full Name
coagulation factor XII, partial
NCBI Official Synonym Full Names
coagulation factor XII (Hageman factor)
NCBI Official Symbol
F12
NCBI Official Synonym Symbols
HAF; HAE3; HAEX
NCBI Protein Information
coagulation factor XII
UniProt Protein Name
Coagulation factor XII
UniProt Gene Name
F12
UniProt Synonym Gene Names
HAF
UniProt Entry Name
FA12_HUMAN

NCBI Description

This gene encodes coagulation factor XII which circulates in blood as a zymogen. This single chain zymogen is converted to a two-chain serine protease with an heavy chain (alpha-factor XIIa) and a light chain. The heavy chain contains two fibronectin-type domains, two epidermal growth factor (EGF)-like domains, a kringle domain and a proline-rich domain, whereas the light chain contains only a catalytic domain. On activation, further cleavages takes place in the heavy chain, resulting in the production of beta-factor XIIa light chain and the alpha-factor XIIa light chain becomes beta-factor XIIa heavy chain. Prekallikrein is cleaved by factor XII to form kallikrein, which then cleaves factor XII first to alpha-factor XIIa and then to beta-factor XIIa. The active factor XIIa participates in the initiation of blood coagulation, fibrinolysis, and the generation of bradykinin and angiotensin. It activates coagulation factors VII and XI. Defects in this gene do not cause any clinical symptoms and the sole effect is that whole-blood clotting time is prolonged. [provided by RefSeq, Jul 2008]

Uniprot Description

F12: Factor XII is a serum glycoprotein that participates in the initiation of blood coagulation, fibrinolysis, and the generation of bradykinin and angiotensin. Prekallikrein is cleaved by factor XII to form kallikrein, which then cleaves factor XII first to alpha-factor XIIa and then trypsin cleaves it to beta- factor XIIa. Alpha-factor XIIa activates factor XI to factor XIa. Defects in F12 are the cause of factor XII deficiency (FA12D); also known as Hageman factor deficiency. This trait is an asymptomatic anomaly of in vitro blood coagulation. Its diagnosis is based on finding a low plasma activity of the factor in coagulating assays. It is usually only accidentally discovered through pre-operative blood tests. F12 deficiency is divided into two categories, a cross-reacting material (CRM)-negative group (negative F12 antigen detection) and a CRM-positive group (positive F12 antigen detection). Defects in F12 are the cause of hereditary angioedema type 3 (HAE3); also known as estrogen-related HAE or hereditary angioneurotic edema with normal C1 inhibitor concentration and function. HAE is characterized by episodic local subcutaneous edema, and submucosal edema involving the upper respiratory and gastrointestinal tracts. HAE3 occurs exclusively in women and is precipitated or worsened by high estrogen levels (e.g. during pregnancy or treatment with oral contraceptives). It differs from HAE types 1 and 2 in that both concentration and function of C1 inhibitor are normal. Belongs to the peptidase S1 family.

Protein type: EC 3.4.21.38; Secreted; Secreted, signal peptide; Protease; Chaperone

Chromosomal Location of Human Ortholog: 5q35.3

Cellular Component: extracellular space; plasma membrane; extracellular region

Molecular Function: protein binding; serine-type endopeptidase activity; misfolded protein binding

Biological Process: protein autoprocessing; fibrinolysis; response to misfolded protein; positive regulation of blood coagulation; plasma kallikrein-kinin cascade; positive regulation of fibrinolysis; innate immune response; protein processing; zymogen activation; blood coagulation; blood coagulation, intrinsic pathway; Factor XII activation

Disease: Angioedema, Hereditary, Type Iii; Factor Xii Deficiency

Research Articles on FXII

Similar Products

Product Notes

The Rat FXII f12 (Catalog #AAA2531102) is a CLIA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2531102 CLIA Kit recognizes Rat FXII. It is sometimes possible for the material contained within the vial of "FXII (Coagulation Factor XII), CLIA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote