Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Western Blot (WB) (Western blot analysis of LAMP-1 in EL4 cell lysate with LAMP-1 antibody at (A) 1 and (B) 2 μg/mL.)

Rabbit LAMP-1 Polyclonal Antibody | anti-LAMP1 antibody

LAMP-1 Antibody

Gene Names
LAMP1; LAMPA; CD107a; LGP120
Reactivity
Human, Mouse, Rat
Applications
ELISA, Western Blot, Immunohistochemistry, Immunofluorescence
Purity
LAMP-1 Antibody is affinity chromatography purified via peptide column.
Synonyms
LAMP-1; Polyclonal Antibody; LAMP-1 Antibody; LAMPA; CD107a; LGP120; Lysosome-associated membrane glycoprotein 1; CD107 antigen-like family member A; lysosomal-associated membrane protein 1; anti-LAMP1 antibody
Ordering
For Research Use Only!
Host
Rabbit
Reactivity
Human, Mouse, Rat
Clonality
Polyclonal
Isotype
IgG
Specificity
LAMP-1 antibody is predicted to not cross-react with LAMP-2. Due to extensive post-translational modification, LAMP-1 often migrates at higher than predicted molecular weight in SDS-PAGE.
Purity/Purification
LAMP-1 Antibody is affinity chromatography purified via peptide column.
Form/Format
Liquid
Concentration
1 mg/mL (varies by lot)
Sequence Length
417
Applicable Applications for anti-LAMP1 antibody
ELISA (EIA), Western Blot (WB), Immunohistochemistry (IHC), Immunofluorescence (IF)
Application Notes
LAMP-1 antibody can be used for the detection of LAMP-1 by Western blot at 1 - 2 mug/mL. Antibody can also be used for immunohistochemistry starting at 20 mug/mL. For immunofluorescence start at 20 mug/mL.
Conjugate
Unconjugated
Immunogen
LAMP-1 antibody was raised against a 15 amino acid synthetic peptide from near the center of human LAMP-1.
Buffer
LAMP-1 Antibody is supplied in PBS containing 0.02% sodium azide.
Preparation and Storage
LAMP-1 antibody can be stored at 4 degree C for three months and -20 degree C, stable for up to one year. As with all antibodies care should be taken to avoid repeated freeze thaw cycles. Antibodies should not be exposed to prolonged high temperatures.

Western Blot (WB)

(Western blot analysis of LAMP-1 in EL4 cell lysate with LAMP-1 antibody at (A) 1 and (B) 2 μg/mL.)

Western Blot (WB) (Western blot analysis of LAMP-1 in EL4 cell lysate with LAMP-1 antibody at (A) 1 and (B) 2 μg/mL.)

Immunofluorescence (IF)

(Immunofluorescence of LAMP-1 in human colon tissue with LAMP-1 antibody at 20 μg/mL.)

Immunofluorescence (IF) (Immunofluorescence of LAMP-1 in human colon tissue with LAMP-1 antibody at 20 μg/mL.)

Immunofluorescence (IF)

(Immunofluorescence of LAMP-1 in Human Colon cells with LAMP-1 antibody at 20 μg/mL.)

Immunofluorescence (IF) (Immunofluorescence of LAMP-1 in Human Colon cells with LAMP-1 antibody at 20 μg/mL.)

Immunohistochemistry (IHC)

(Immunohistochemistry of LAMP-1 in rat colon tissue with LAMP-1 antibody at 2.5 μg/ml.)

Immunohistochemistry (IHC) (Immunohistochemistry of LAMP-1 in rat colon tissue with LAMP-1 antibody at 2.5 μg/ml.)

Immunofluorescence (IF)

(Immunofluorescence of LAMP-1 in rat colon tissue with LAMP-1 antibody at 20 μg/ml.)

Immunofluorescence (IF) (Immunofluorescence of LAMP-1 in rat colon tissue with LAMP-1 antibody at 20 μg/ml.)
Related Product Information for anti-LAMP1 antibody
LAMP-1 Antibody: Autophagy, the process of bulk degradation of cellular proteins through an autophagosomic-lysosomal pathway is important for normal growth control and may be defective in tumor cells. It is involved in the preservation of cellular nutrients under starvation conditions as well as the normal turnover of cytosolic components and is negatively regulated by TOR (Target of rapamycin). A protein recently found to be involved in autophagy, LAMP-2, is a highly glycosylated protein associated with the lysosome. LAMP-1 shares much homology to LAMP-2 and is thought to have overlapping functions. Mice lacking LAMP-1 had very minor defects compared to those deficient in LAMP-2 expression. However, the loss of both proteins resulted in embryonic lethality, suggesting that each protein possesses some unique and necessary functions.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
Predicted: 46 kDa

Observed: 100 kDa
NCBI Official Full Name
lysosome-associated membrane glycoprotein 1
NCBI Official Synonym Full Names
lysosomal-associated membrane protein 1
NCBI Official Symbol
LAMP1
NCBI Official Synonym Symbols
LAMPA; CD107a; LGP120
NCBI Protein Information
lysosome-associated membrane glycoprotein 1; LAMP-1; CD107 antigen-like family member A; lysosome-associated membrane protein 1
UniProt Protein Name
Lysosome-associated membrane glycoprotein 1
UniProt Gene Name
LAMP1
UniProt Synonym Gene Names
LAMP-1; Lysosome-associated membrane protein 1
UniProt Entry Name
LAMP1_HUMAN

NCBI Description

The protein encoded by this gene is a member of a family of membrane glycoproteins. This glycoprotein provides selectins with carbohydrate ligands. It may also play a role in tumor cell metastasis. [provided by RefSeq, Jul 2008]

Uniprot Description

LAMP1: Presents carbohydrate ligands to selectins. Also implicated in tumor cell metastasis. Belongs to the LAMP family.

Protein type: Membrane protein, integral

Chromosomal Location of Human Ortholog: 13q34

Cellular Component: lysosome; integral to plasma membrane; dendrite; multivesicular body; cell soma; membrane; cytoplasm; late endosome; plasma membrane; melanosome; endosome membrane; sarcolemma; external side of plasma membrane

Molecular Function: protein domain specific binding; protein binding; enzyme binding

Biological Process: positive regulation of natural killer cell degranulation; induction of apoptosis by granzyme; viral reproduction; protein stabilization; autophagic cell death; autophagy; positive regulation of natural killer cell mediated cytotoxicity

Research Articles on LAMP1

Similar Products

Product Notes

The LAMP1 lamp1 (Catalog #AAA151533) is an Antibody produced from Rabbit and is intended for research purposes only. The product is available for immediate purchase. The LAMP-1 Antibody reacts with Human, Mouse, Rat and may cross-react with other species as described in the data sheet. AAA Biotech's LAMP-1 can be used in a range of immunoassay formats including, but not limited to, ELISA (EIA), Western Blot (WB), Immunohistochemistry (IHC), Immunofluorescence (IF). LAMP-1 antibody can be used for the detection of LAMP-1 by Western blot at 1 - 2 mug/mL. Antibody can also be used for immunohistochemistry starting at 20 mug/mL. For immunofluorescence start at 20 mug/mL. Researchers should empirically determine the suitability of the LAMP1 lamp1 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "LAMP-1, Polyclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.