Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Western Blot (WB) (Western blot analysis of AES in 293 cell lysate with AES antibody at (A) 2 and (B) 4 μg/mL.)

Rabbit anti-Human, Mouse AES Polyclonal Antibody | anti-AES antibody

AES Antibody

Gene Names
AES; GRG; ESP1; GRG5; TLE5; AES-1; AES-2; Grg-5
Reactivity
Human, Mouse
Applications
ELISA, Western Blot, Immunocytochemistry, Immunofluorescence
Purity
AES Antibody is affinity chromatography purified via peptide column.
Synonyms
AES; Polyclonal Antibody; AES Antibody; GRG; ESP1; GRG5; TLE5; AES-1; AES-2; Amino-terminal enhancer of split; Gp130-associated protein GAM; Amino enhancer of split; amino-terminal enhancer of split; anti-AES antibody
Ordering
For Research Use Only!
Host
Rabbit
Reactivity
Human, Mouse
Clonality
Polyclonal
Isotype
IgG
Purity/Purification
AES Antibody is affinity chromatography purified via peptide column.
Form/Format
Liquid
Concentration
1 mg/mL (varies by lot)
Sequence Length
264
Applicable Applications for anti-AES antibody
ELISA (EIA), Western Blot (WB), Immunocytochemistry (ICC), Immunofluorescence (IF)
Application Notes
AES antibody can be used for the detection of AES by Western blot at 2 - 4 mug/mL. Antibody can also be used for immunocytochemistry starting at 10 mug/mL. For immunofluorescence start at 20 mug/mL.
Conjugate
Unconjugated
Immunogen
AES antibody was raised against a 16 amino acid synthetic peptide from near the amino-terminus of human AES.
Buffer
AES Antibody is supplied in PBS containing 0.02% sodium azide.
Preparation and Storage
AES antibody can be stored at 4 degree C for three months and -20 degree C, stable for up to one year. As with all antibodies care should be taken to avoid repeated freeze thaw cycles. Antibodies should not be exposed to prolonged high temperatures.

Western Blot (WB)

(Western blot analysis of AES in 293 cell lysate with AES antibody at (A) 2 and (B) 4 μg/mL.)

Western Blot (WB) (Western blot analysis of AES in 293 cell lysate with AES antibody at (A) 2 and (B) 4 μg/mL.)

Immunocytochemistry (IHC)

(Immunocytochemistry of AES in 293 cells with AES antibody at 10 μg/mL. )

Immunocytochemistry (IHC) (Immunocytochemistry of AES in 293 cells with AES antibody at 10 μg/mL. )

Immunofluorescence (IF)

(Immunofluorescence of AES in 293 cells with AES antibody at 20 μg/mL.)

Immunofluorescence (IF) (Immunofluorescence of AES in 293 cells with AES antibody at 20 μg/mL.)
Related Product Information for anti-AES antibody
AES Antibody: Adhesion to extracellular matrix regulates cell survival through both integrin engagement and appropriate cell spreading. Anoikis is the molecular mechanism of apop-tosis induced by integrin detachment. Amino-terminal enhancer of split (AES) is a member of the Groucho/ transducin-like enhancer of split (TLE) family of transcriptional regulators, a group of transcriptional co-repressors that play important roles in neurogenesis, segmentation, and sex determination. AES forms a complex with Bit1 (Bcl-2 inhibitor of transcription 1), a mitochondrial protein that is released into the cytoplasm upon onset of apoptosis. It has been suggested that this complex turns off a survival-promoting gene transcription program controlled by the TLE protein family. Interestingly, apoptosis of cells transfected with AES and Bit1 could be inhibited if the cells were allowed to attach to fibronectin through the alpha5beta1 integrin suggesting that the Bit1-AES pathway contributing to anoikis is regulated by integrins, and in particular, the alpha5beta1 integrin.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
166
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
29,091 Da
NCBI Official Full Name
amino-terminal enhancer of split isoform a
NCBI Official Synonym Full Names
amino-terminal enhancer of split
NCBI Official Symbol
AES
NCBI Official Synonym Symbols
GRG; ESP1; GRG5; TLE5; AES-1; AES-2; Grg-5
NCBI Protein Information
amino-terminal enhancer of split; groucho-related protein 5; gp130-associated protein GAM
UniProt Protein Name
Amino-terminal enhancer of split
Protein Family
UniProt Gene Name
AES
UniProt Synonym Gene Names
GRG; GRG5; Amino enhancer of split
UniProt Entry Name
AES_HUMAN

NCBI Description

The protein encoded by this gene is similar in sequence to the amino terminus of Drosophila enhancer of split groucho, a protein involved in neurogenesis during embryonic development. The encoded protein, which belongs to the groucho/TLE family of proteins, can function as a homooligomer or as a heteroologimer with other family members to dominantly repress the expression of other family member genes. Three transcript variants encoding different isoforms have been found for this gene. [provided by RefSeq, Jul 2008]

Uniprot Description

AES: Acts as dominant repressor towards other family members. Inhibits NF-kappa-B-regulated gene expression. May be required for the initiation and maintenance of the differentiated state. Belongs to the WD repeat Groucho/TLE family. 2 isoforms of the human protein are produced by alternative splicing.

Protein type: Nuclear receptor co-regulator; Transcription, coactivator/corepressor

Chromosomal Location of Human Ortholog: 19p13.3

Cellular Component: nucleus

Molecular Function: protein binding; transcription corepressor activity

Biological Process: organ morphogenesis; Wnt receptor signaling pathway; transcription, DNA-dependent; multicellular organismal development; regulation of growth; cellular response to extracellular stimulus; negative regulation of transcription from RNA polymerase II promoter; negative regulation of transcription, DNA-dependent; negative regulation of protein binding; skeletal development

Research Articles on AES

Similar Products

Product Notes

The AES aes (Catalog #AAA150869) is an Antibody produced from Rabbit and is intended for research purposes only. The product is available for immediate purchase. The AES Antibody reacts with Human, Mouse and may cross-react with other species as described in the data sheet. AAA Biotech's AES can be used in a range of immunoassay formats including, but not limited to, ELISA (EIA), Western Blot (WB), Immunocytochemistry (ICC), Immunofluorescence (IF). AES antibody can be used for the detection of AES by Western blot at 2 - 4 mug/mL. Antibody can also be used for immunocytochemistry starting at 10 mug/mL. For immunofluorescence start at 20 mug/mL. Researchers should empirically determine the suitability of the AES aes for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "AES, Polyclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.