Typical Testing Data/Standard Curve (for reference only)

Mouse Erythropoietin (EPO) CLIA Kit | EPO clia kit

Mouse Erythropoietin (EPO) CLIA Kit

Gene Names
EPO; EP; MVCD2
Reactivity
Mouse
Synonyms
Erythropoietin (EPO); Mouse Erythropoietin (EPO) CLIA Kit; EP; Epoetin; Erythropoetin; Hematopoietin; Hemopoietin; EPO clia kit
Ordering
For Research Use Only!
Reactivity
Mouse
Specificity
This assay has high sensitivity and excellent specificity for detection of Erythropoietin (EPO).
No significant cross-reactivity or interference between Erythropoietin (EPO) and analogues was observed.
Sequence Length
193
Assay Type
Double-antibody Sandwich
Samples
Serum, Plasma, Tissue homogenates, Cell lysates and Other Biological Fluids
Detection Range
1.37-1,000pg/mL
Sensitivity
< 0.59pg/mL
Application
Chemiluminescent immunoassay for Antigen Detection.
Intra-assay Precision (Precision within an assay)
3 samples with low, middle and high level Erythropoietin (EPO) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays)
3 samples with low, middle and high level Erythropoietin (EPO) were tested on 3 different plates, 8 replicates in each plate.
CV(%) =
SD/meanX100
Intra-Assay
CV<10%
Inter-Assay
CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for EPO clia kit
The microplate provided in this kit has been pre-coated with an antibody specific to Erythropoietin (EPO). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Erythropoietin (EPO). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Erythropoietin (EPO) level in the sample or standard.;
Product Categories/Family for EPO clia kit

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
Molecular Weight
21,307 Da
NCBI Official Full Name
erythropoietin
NCBI Official Synonym Full Names
erythropoietin
NCBI Official Symbol
EPO
NCBI Official Synonym Symbols
EP; MVCD2
NCBI Protein Information
erythropoietin
UniProt Protein Name
Erythropoietin
Protein Family
UniProt Gene Name
EPO
UniProt Entry Name
EPO_HUMAN

NCBI Description

This gene is a member of the EPO/TPO family and encodes a secreted, glycosylated cytokine composed of four alpha helical bundles. The protein is found in the plasma and regulates red cell production by promoting erythroid differentiation and initiating hemoglobin synthesis. This protein also has neuroprotective activity against a variety of potential brain injuries and antiapoptotic functions in several tissue types. [provided by RefSeq, Jul 2008]

Uniprot Description

EPO: Erythropoietin is the principal hormone involved in the regulation of erythrocyte differentiation and the maintenance of a physiological level of circulating erythrocyte mass. Genetic variation in EPO is associated with susceptbility to microvascular complications of diabetes type 2 (MVCD2). These are pathological conditions that develop in numerous tissues and organs as a consequence of diabetes mellitus. They include diabetic retinopathy, diabetic nephropathy leading to end-stage renal disease, and diabetic neuropathy. Diabetic retinopathy remains the major cause of new-onset blindness among diabetic adults. It is characterized by vascular permeability and increased tissue ischemia and angiogenesis. Belongs to the EPO/TPO family.

Protein type: Secreted; Secreted, signal peptide

Chromosomal Location of Human Ortholog: 7q22

Cellular Component: extracellular space; cell surface; extracellular region

Molecular Function: protein binding; erythropoietin receptor binding; hormone activity; protein kinase activator activity

Biological Process: hemoglobin biosynthetic process; erythrocyte maturation; apoptosis; blood circulation; positive regulation of transcription, DNA-dependent; response to lipopolysaccharide; response to testosterone stimulus; signal transduction; response to salt stress; response to vitamin A; peptidyl-serine phosphorylation; response to hyperoxia; positive regulation of tyrosine phosphorylation of Stat5 protein; response to estrogen stimulus; positive regulation of protein kinase activity; positive regulation of cell proliferation; response to axon injury; positive regulation of Ras protein signal transduction; response to electrical stimulus; positive regulation of neuron differentiation; embryo implantation; positive regulation of DNA replication; aging

Disease: Microvascular Complications Of Diabetes, Susceptibility To, 2

Research Articles on EPO

Similar Products

Product Notes

The Mouse EPO epo (Catalog #AAA2025397) is a CLIA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2025397 CLIA Kit recognizes Mouse EPO. It is sometimes possible for the material contained within the vial of "Erythropoietin (EPO), CLIA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.