Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Western Blot (WB) (Figure. Western Blot: Sample: Recombinant SELP, Human)

Mouse anti-Human Selectin, Platelet (SELP) Monoclonal Antibody | anti-SELP antibody

Monoclonal Antibody to Selectin, Platelet (SELP)

Gene Names
SELP; CD62; GRMP; PSEL; CD62P; GMP140; LECAM3; PADGEM
Reactivity
Human
Applications
Western Blot, Immunohistochemistry, Immunocytochemistry, Immunoprecipitation
Purity
Antigen-specific affinity chromatography followed by Protein A affinity chromatography
Synonyms
Selectin; Platelet (SELP); Monoclonal Antibody; Monoclonal Antibody to Selectin; CD & Adhesion molecule; Tumor immunity; Infection immunity; anti-SELP antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human
Clonality
Monoclonal
Isotype
IgG1 Kappa
Clone Number
C9
Specificity
The antibody is a mouse monoclonal antibody raised against SELP. It has been selected for its ability to recognize SELP in immunohistochemical staining and western blotting.
Purity/Purification
Antigen-specific affinity chromatography followed by Protein A affinity chromatography
Form/Format
Liquid; PBS, pH7.4, containing 0.02% NaN3, 50% glycerol.
Concentration
1mg/mL (varies by lot)
Sequence
Arg198~Asn432
Sequence Length
830
Applicable Applications for anti-SELP antibody
Western Blot (WB), Immunohistochemistry (IHC), Immunocytochemistry (ICC), Immunoprecipitation (IP)
Application Notes
WB: 0.5-2ug/mL
IHC: 5-20ug/mL
ICC: 5-20ug/mL
Conjugation
None
Cross Reactivity
Human
Preparation and Storage
Store at 4 degree C for frequent use. Aliquot and store at -20 degree C for 12 months.
Avoid repeated freeze/thaw cycles.

The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37 degree C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.

Western Blot (WB)

(Figure. Western Blot: Sample: Recombinant SELP, Human)

Western Blot (WB) (Figure. Western Blot: Sample: Recombinant SELP, Human)

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
UniProt Accession #
NCBI Official Full Name
granule membrane protein-140
NCBI Official Synonym Full Names
selectin P
NCBI Official Symbol
SELP
NCBI Official Synonym Symbols
CD62; GRMP; PSEL; CD62P; GMP140; LECAM3; PADGEM
NCBI Protein Information
P-selectin
UniProt Protein Name
P-selectin
Protein Family
UniProt Gene Name
SELP
UniProt Synonym Gene Names
GMRP; GRMP; GMP-140; LECAM3; PADGEM
UniProt Entry Name
LYAM3_HUMAN

NCBI Description

This gene encodes a 140 kDa protein that is stored in the alpha-granules of platelets and Weibel-Palade bodies of endothelial cells. This protein redistributes to the plasma membrane during platelet activation and degranulation and mediates the interaction of activated endothelial cells or platelets with leukocytes. The membrane protein is a calcium-dependent receptor that binds to sialylated forms of Lewis blood group carbohydrate antigens on neutrophils and monocytes. Alternative splice variants may occur but are not well documented. [provided by RefSeq, Jul 2008]

Uniprot Description

SELP: Ca(2+)-dependent receptor for myeloid cells that binds to carbohydrates on neutrophils and monocytes. Mediates the interaction of activated endothelial cells or platelets with leukocytes. The ligand recognized is sialyl-Lewis X. Mediates rapid rolling of leukocyte rolling over vascular surfaces during the initial steps in inflammation through interaction with PSGL1. Defects in SELP may be a cause of susceptibility to ischemic stroke (ISCHSTR); also known as cerebrovascular accident or cerebral infarction. A stroke is an acute neurologic event leading to death of neural tissue of the brain and resulting in loss of motor, sensory and/or cognitive function. Ischemic strokes, resulting from vascular occlusion, is considered to be a highly complex disease consisting of a group of heterogeneous disorders with multiple genetic and environmental risk factors. Belongs to the selectin/LECAM family.

Protein type: Cell adhesion; Membrane protein, integral

Chromosomal Location of Human Ortholog: 1q22-q25

Cellular Component: nucleoplasm; extracellular space; platelet alpha granule membrane; integral to plasma membrane; cytoplasm; plasma membrane; platelet dense granule membrane; external side of plasma membrane

Molecular Function: heparin binding; protein binding; lipopolysaccharide binding; glycosphingolipid binding; glycoprotein binding; calcium-dependent protein binding; sialic acid binding; fucose binding

Biological Process: positive regulation of phosphoinositide 3-kinase cascade; heterophilic cell adhesion; platelet activation; leukocyte adhesion; platelet degranulation; regulation of integrin activation; positive regulation of leukocyte migration; response to lipopolysaccharide; defense response to Gram-negative bacterium; blood coagulation; inflammatory response; leukocyte tethering or rolling; cell adhesion; leukocyte migration

Disease: Ige Responsiveness, Atopic

Research Articles on SELP

Similar Products

Product Notes

The SELP selp (Catalog #AAA2111159) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The Monoclonal Antibody to Selectin, Platelet (SELP) reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's Selectin, Platelet (SELP) can be used in a range of immunoassay formats including, but not limited to, Western Blot (WB), Immunohistochemistry (IHC), Immunocytochemistry (ICC), Immunoprecipitation (IP). WB: 0.5-2ug/mL IHC: 5-20ug/mL ICC: 5-20ug/mL. Researchers should empirically determine the suitability of the SELP selp for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. The amino acid sequence is listed below: Arg198~Asn 432. It is sometimes possible for the material contained within the vial of "Selectin, Platelet (SELP), Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.