Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Rat LAMP2 Monoclonal Antibody

Anti-LAMP2 Monoclonal Antibody

Applications
Immunocytochemistry, Immunoprecipitation
Synonyms
LAMP2; Monoclonal Antibody; Anti-LAMP2 Monoclonal Antibody; LAMP2 Antibody; anti-LAMP2 antibody
Ordering
For Research Use Only!
Host
Rat
Clonality
Monoclonal
Isotype
IgG1
Specificity
LAMP2 Antibody [Rat monoclonal antibody recognizes LAMP2 of mouse and rabbit]
This antibody recognizes mouse and rabbit LAMP2 (~110 kDa).
Form/Format
100ug in PBS, pH 7.4, purified by Protein G affinity chromatography
Applicable Applications for anti-LAMP2 antibody
Immunocytochemistry, Immunoprecipitation
Application Notes
Immunocytochemistry: use at 1-2ug/ml. This antibody will label lysosomes and late endosomes in cells that have been permeabilized with saponin.
Immunoprecipitation, Affinity purification: user should determine optimal conditions for their applications.
These are recommended concentrations. User should determine optimal concentrations for their application.
Positive control: NIH-3T3 or J774 cells
Antigen
Gluteraldehyde-fixed mouse liver lysosomes
Preservatives
0.09% sodium azide
Other Additives
50% glycerol
Dilutions Instructions
Dilute in PBS or medium which is identical to that used in the assay system.
Preparation and Storage
This antibody is stable for at least one (1) year at -20 degree C. Avoid repeated freezing and thawing.
Related Product Information for anti-LAMP2 antibody
Lysosome-associated membrane proteins (LAMP1 and LAMP2) are major constituents of the lysosomal membrane. These two proteins have closely related structures with 37% sequence homology. Both are transmembrane glycoproteins localized primarily in lysosomes and late endosomes. LAMP2 has also been detected at the plasma membrane of cells undergoing differentiation and activation and in cells that secrete lysosomal hydrolases. In addition, it has been suggested that LAMP2 is involved in cell-cell or cell-extracellular matrix interactions. Cell surface LAMP1 and LAMP2 promote adhesion of human peripheral blood mononuclear cells (PBMC) to vascular endothelium which suggests that the LAMP proteins are involved in adhesion of PBMC to sites of inflammation. Studies with LAMP2-deficient mice indicate that involvement of LAMP2 is critical in the conversion of early autophagic vacuoles to vacuoles which rapidly degrade their contents. Defects in LAMP2 are associated with Danon disease.
Product Categories/Family for anti-LAMP2 antibody
References
Granger, BL et al. 1990 J Biol Chem 265: 12036-12043

Similar Products

Product Notes

The LAMP2 (Catalog #AAA190486) is an Antibody produced from Rat and is intended for research purposes only. The product is available for immediate purchase. AAA Biotech's LAMP2 can be used in a range of immunoassay formats including, but not limited to, Immunocytochemistry, Immunoprecipitation. Immunocytochemistry: use at 1-2ug/ml. This antibody will label lysosomes and late endosomes in cells that have been permeabilized with saponin.
Immunoprecipitation, Affinity purification: user should determine optimal conditions for their applications. These are recommended concentrations. User should determine optimal concentrations for their application. Positive control: NIH-3T3 or J774 cells. Researchers should empirically determine the suitability of the LAMP2 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "LAMP2, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.