Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Western Blot (WB)

Mouse LAMP1 Monoclonal Antibody | anti-LAMP1 antibody

LAMP1 Antibody

Reactivity
Human, cow, pig, mouse, rat and other mammals
Applications
Immunofluorescence, Western Blot
Purity
Affinity purified
Synonyms
LAMP1; Monoclonal Antibody; LAMP1 Antibody; anti-LAMP1 antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human, cow, pig, mouse, rat and other mammals
Clonality
Monoclonal
Isotype
IgG1
Purity/Purification
Affinity purified
Form/Format
Liquid
Concentration
100ug/100ul (varies by lot)
Applicable Applications for anti-LAMP1 antibody
Immunofluorescence (IF), Western Blot (WB)
Application Notes
The antibody solution can be used at dilutions of at least 1:2,000 in immunofluorescence experiments. In western blotting using chemiluminescence it can be used at dilutions of 1:10,000 or lower.
Immunogen
As the name suggests, LAMP1 is a protein primarily associated with the lysosomal membrane. Antibodies to LAMP1 are therefore excellent markers of lysosomes in mammalian cells, though some LAMP1 may also be seen on late endosomes and on the plasma membrane. In a typical cell LAMP1 is associated with spherical vesicles located next to the nucleus and the microtubule organizing center (1). The protein is also known as CD107a, lysosomal associated membrane glycoprotein 1, LGP120 and LAMPA, as the protein was independently discovered and named by several different labs. CD is an abbreviation for "Cluster of Differentiation" and refers to a protocol for the naming of proteins and other surface markers of human leucocytes defined by binding of specific monoclonal antibodies. LAMP1 is found on the cell surface of lymphocytes undergoing degranulation, a process in which cytoplasmic vesicles fuse with the plasma membrane, and this phenomena resulted in discovery of LAMP1 as a CD protein. The LAMP1 protein has a large N-terminal region which is inside the lysosome, hence topologically external to the cell, which is often refered to as the lumenal domain (2). The lumenal domain consists of two homologous globular seqments separated by a proline rich sequence. Next there is a single membrane spanning domain and a short 11 amino acid C-terminal cytoplasmic tail. This tail region contains, at the extreme C-terminus, a so-called YXXI motif which is responsible for the sorting of the intact molecule to the endosome and lysozome, where Y = tyrosine, I = isoleucine and X = almost any amino acid (3). This motif is found in several other lysosomal proteins, where it functions in the same way. There are 417 amino acids in the human LAMP1 molecule, giving a native molecular weight of 44.8kDa. However the N-terminal lumenal segment of LAMP1 is very heavily and variably glycosylated due to the presence of 18 N-linked glycosylation sites, so that on SDS-PAGE and on Western blots the protein runs as a diffuse band at 90-120kDa. The HGNC name for this protein is LAMP1.
Storage Buffer
PBS, pH 7.4 with 0.02% sodium azide.
Preparation and Storage
Store at -20 degree C/1 year

Western Blot (WB)

Western Blot (WB)
References
1. Matteoni, R. and Kreiss, T. E. Translocation and clustering of endosomes and lysosomes depends on microtubules. J. Cell Biol. 105:1253-1265 (1987).2. Howe CL, Granger BL, Hull M, Green SA, Gabel CA, Helenius A, Mellman I. Derived protein sequence, oligosaccharides, and membrane insertion of the 120-kDa lysosomal membrane glycoprotein (lgp120): identification of a highly conserved family of lysosomal membrane glycoproteins. Proc Natl Acad Sci U S A. 85:7577-81 (1988).3. Rohrer J, Schweizer A, Russell D, Kornfeld S. The targeting of Lamp1 to lysosomes is dependent on the spacing of its cytoplasmic tail tyrosine sorting motif relative to the membrane. J Cell Biol. 132:565-76 (1996).

Similar Products

Product Notes

The LAMP1 (Catalog #AAA415068) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The LAMP1 Antibody reacts with Human, cow, pig, mouse, rat and other mammals and may cross-react with other species as described in the data sheet. AAA Biotech's LAMP1 can be used in a range of immunoassay formats including, but not limited to, Immunofluorescence (IF), Western Blot (WB). The antibody solution can be used at dilutions of at least 1:2,000 in immunofluorescence experiments. In western blotting using chemiluminescence it can be used at dilutions of 1:10,000 or lower. Researchers should empirically determine the suitability of the LAMP1 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "LAMP1, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.