Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Low density lipoprotein immune complex ELISA Kit | LDL IC elisa kit

Human Low density lipoprotein immune complex ELISA Kit

Reactivity
Human
Synonyms
Low density lipoprotein immune complex; Human Low density lipoprotein immune complex ELISA Kit; LDL IC elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Samples
Serum, plasma, Cell Culture Supernatants, body fluid and tissue homogenate
Assay Type
Competitive
Detection Range
2.5-50ng/mL
Sensitivity
0.1ng/mL
Preparation and Storage
Store all reagents at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for LDL IC elisa kit
For Samples: Cell culture fluid, body fluid, tissue homogenate, serum and blood plasma

Intended Uses: This LDL-IC ELISA kit is intended for laboratory research use only. The stop solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of LDL-IC in the sample, this LDL-IC ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus LDL-IC concentration. The concentration of in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Principle of the Assay: The coated well immunoenzymatic assay for the quantitative measurement of LDL-IC utilizes a multiclonal anti-LDL-IC antibody and an LDL-IC-HRP conjugate. The assay sample and buffer are incubated together with LDL-IC-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the LDL-IC concentration since LDL-IC from samples and LDL-IC-HRP conjugate compete for the anti-LDL-IC antibody binding site. Since the number of sites is limited, as more sites are occupied by LDL-IC from the sample, fewer sites are left to bind LDL-IC-HRP conjugate. Standards of known LDL-IC concentrations are run concurrently with the samples being assayed and a standard curve is plotted relating the intensity of the color (Optical Density) to the concentration of LDL-IC. The LDL-IC concentration in each sample is interpolated from this standard curve.
Product Categories/Family for LDL IC elisa kit

Similar Products

Product Notes

The Human LDL IC (Catalog #AAA726483) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA726483 ELISA Kit recognizes Human LDL IC. It is sometimes possible for the material contained within the vial of "Low density lipoprotein immune complex, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.