Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Immunosuppressive Acidic Protein ELISA Kit | IAP elisa kit

Human Immunosuppressive Acidic Protein ELISA Kit

Reactivity
Human
Synonyms
Immunosuppressive Acidic Protein; Human Immunosuppressive Acidic Protein ELISA Kit; IAP elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of IAP. No significant cross-reactivity or interference between IAP and analogues was observed. NOTE: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between IAP and all the analogues, therefore, cross reaction may still exist in some cases.
Samples
Serum, plasma, cell culture supernatants, body fluid and tissue homogenate
Assay Type
Competitive or Sandwich
Sensitivity
1.0 ug/mL
Preparation and Storage
Store all reagents at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for IAP elisa kit
Intended Uses: This IAP ELISA kit is a 1.5 hour solid-phase ELISA designed for the quantitative determination of Human IAP. This ELISA kit for research use only!

Principle of the Assay: IAP ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-IAP antibody and an IAP-HRP conjugate. The assay sample and buffer are incubated together with IAP-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the IAP concentration since IAP from samples and IAP-HRP conjugate compete for the anti-IAP antibody binding site. Since the number of sites is limited, as more sites are occupied by IAP from the sample, fewer sites are left to bind IAP-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The IAP concentration in each sample is interpolated from this standard curve.
Product Categories/Family for IAP elisa kit

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
Molecular Weight
25,829 Da
NCBI Official Full Name
iap
NCBI Official Symbol
ClgVgp085
NCBI Protein Information
orf85; iap
UniProt Protein Name
Iap
Protein Family
UniProt Entry Name
Q7T5K8_GVCL

Similar Products

Product Notes

The Human IAP (Catalog #AAA723474) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA723474 ELISA Kit recognizes Human IAP. It is sometimes possible for the material contained within the vial of "Immunosuppressive Acidic Protein, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.