Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Signal Transducer And Activator Of Transcription 4 (STAT4) ELISA Kit | STAT4 elisa kit

Human Signal Transducer And Activator Of Transcription 4 (STAT4) ELISA Kit

Gene Names
STAT4; SLEB11
Reactivity
Human
Synonyms
Signal Transducer And Activator Of Transcription 4 (STAT4); Human Signal Transducer And Activator Of Transcription 4 (STAT4) ELISA Kit; STAT4 elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of Signal Transducer And Activator Of Transcription 4 (STAT4).
No significant cross-reactivity or interference between Signal Transducer And Activator Of Transcription 4 (STAT4) and analogues was observed.
Sequence Length
748
Assay Type
Double-antibody Sandwich
Samples
Tissue homogenates, Cell lysates and Other Biological Fluids
Detection Range
0.312-20ng/mL
Sensitivity
< 0.108ng/mL
Application
Enzyme-linked immunosorbent assay for Antigen Detection.
Intra-assay Precision (Precision within an assay)
3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 4 (STAT4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays)
3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 4 (STAT4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) =
SD/meanX100
Intra-Assay
CV<10%
Inter-Assay
CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for STAT4 elisa kit
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Signal Transducer And Activator Of Transcription 4 (STAT4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Signal Transducer And Activator Of Transcription 4 (STAT4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Signal Transducer And Activator Of Transcription 4 (STAT4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Signal Transducer And Activator Of Transcription 4 (STAT4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Product Categories/Family for STAT4 elisa kit

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
Molecular Weight
85,941 Da
NCBI Official Full Name
signal transducer and activator of transcription 4
NCBI Official Synonym Full Names
signal transducer and activator of transcription 4
NCBI Official Symbol
STAT4
NCBI Official Synonym Symbols
SLEB11
NCBI Protein Information
signal transducer and activator of transcription 4
UniProt Protein Name
Signal transducer and activator of transcription 4
UniProt Gene Name
STAT4
UniProt Entry Name
STAT4_HUMAN

NCBI Description

The protein encoded by this gene is a member of the STAT family of transcription factors. In response to cytokines and growth factors, STAT family members are phosphorylated by the receptor associated kinases, and then form homo- or heterodimers that translocate to the cell nucleus where they act as transcription activators. This protein is essential for mediating responses to IL12 in lymphocytes, and regulating the differentiation of T helper cells. Mutations in this gene may be associated with systemic lupus erythematosus and rheumatoid arthritis. Alternate splicing results in multiple transcript variants that encode the same protein. [provided by RefSeq, Aug 2011]

Uniprot Description

STAT4: transcription factor of the STAT family. Phosphorylated and activated by receptor-associated kinases downstream of many cytokines and growth-factor receptors. Essential for mediating responses to IL12 in lymphocytes, and regulating the differentiation of T helper cells.

Protein type: Transcription factor; DNA-binding

Chromosomal Location of Human Ortholog: 2q32.2-q32.3

Cellular Component: nucleoplasm; cytoplasm

Molecular Function: signal transducer activity; protein binding; sequence-specific DNA binding; transcription factor activity

Biological Process: cell proliferation; transcription, DNA-dependent; cytokine and chemokine mediated signaling pathway; positive regulation of transcription from RNA polymerase II promoter; JAK-STAT cascade; protein amino acid phosphorylation

Disease: Systemic Lupus Erythematosus, Susceptibility To, 11

Research Articles on STAT4

Similar Products

Product Notes

The Human STAT4 stat4 (Catalog #AAA2024998) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2024998 ELISA Kit recognizes Human STAT4. It is sometimes possible for the material contained within the vial of "Signal Transducer And Activator Of Transcription 4 (STAT4), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote