Typical Testing Data/Standard Curve (for reference only)

Human SDF-2 ELISA Kit | SDF-2 elisa kit

Human SDF-2 (Stromal Cell Derived Factor 2) ELISA Kit

Reactivity
Human
Synonyms
SDF-2; Human SDF-2 (Stromal Cell Derived Factor 2) ELISA Kit; SDF-2 elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This kit recognizes natural and recombinantHumanSDF-2. No significant cross-reactivity or interference between HumanSDF-2 and analogues was observed.
Sequence Length
211
Samples
Serum, Plasma, Biological Fluids
Assay Type
Sandwich
Detection Range
31.25-2000pg/mL
Sensitivity
Min: 18.75pg/mL; Max: 2000pg/mL
Preparation and Storage
Store at 4 degree C.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for SDF-2 elisa kit
Intended Uses: This ELISA kit applies to the invitro quantitative determination of HumanSDF-2concentrations in serum, plasma and other biological fluids.

Principle of the Assay: This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to SDF-2. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for SDF-2and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain SDF-2, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The OD value is proportional to the concentration of SDF-2.You can calculate the concentration of SDF-2in the samples by comparing the OD of the samples to the standard curve.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
23,026 Da
NCBI Official Full Name
stromal cell-derived factor 2
NCBI Official Synonym Full Names
stromal cell-derived factor 2
NCBI Official Symbol
SDF2
NCBI Protein Information
stromal cell-derived factor 2; SDF-2
UniProt Protein Name
Stromal cell-derived factor 2
UniProt Gene Name
SDF2
UniProt Synonym Gene Names
SDF-2
UniProt Entry Name
SDF2_HUMAN

NCBI Description

The protein encoded by this gene is believed to be a secretory protein. It has regions of similarity to hydrophilic segments of yeast mannosyltransferases. Its expression is ubiquitous and the gene appears to be relatively conserved among mammals. Alternate splicing results in both coding and non-coding variants. A pseudogene of this gene is located on chromosome 15. [provided by RefSeq, Dec 2011]

Uniprot Description

SDF2:

Protein type: Secreted; Secreted, signal peptide

Chromosomal Location of Human Ortholog: 17q11.2

Cellular Component: extracellular space; membrane

Molecular Function: dolichyl-phosphate-mannose-protein mannosyltransferase activity

Biological Process: protein amino acid O-linked mannosylation; protein amino acid glycosylation

Research Articles on SDF-2

Similar Products

Product Notes

The Human SDF-2 sdf2 (Catalog #AAA2508153) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2508153 ELISA Kit recognizes Human SDF-2. It is sometimes possible for the material contained within the vial of "SDF-2, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.