Typical Testing Data/Standard Curve (for reference only)

Human Interleukin 12 (IL12) CLIA Kit | IL12 clia kit

Human Interleukin 12 (IL12) CLIA Kit

Gene Names
IL12A; P35; CLMF; NFSK; NKSF1; IL-12A
Reactivity
Human
Applications
Chemiluminescence Immunoassay (CLIA)
Synonyms
Interleukin 12 (IL12); Human Interleukin 12 (IL12) CLIA Kit; Interleukin 12; IL12 clia kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of Interleukin 12 (IL12).
No significant cross-reactivity or interference between Interleukin 12 (IL12) and analogues was observed.
Sequence Length
253
Applicable Applications for IL12 clia kit
Chemiluminescence Immunoassay (CLIA)
Assay Type
Double-antibody Sandwich
Samples
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
0.69-500pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.28pg/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 12 (IL12) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 12 (IL12) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Test Principle
The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 12 (IL12). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 12 (IL12). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 12 (IL12) level in the sample or standard.
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Official Full Name
interleukin 12
NCBI Official Synonym Full Names
interleukin 12A
NCBI Official Symbol
IL12A
NCBI Official Synonym Symbols
P35; CLMF; NFSK; NKSF1; IL-12A
NCBI Protein Information
interleukin-12 subunit alpha

NCBI Description

This gene encodes a subunit of a cytokine that acts on T and natural killer cells, and has a broad array of biological activities. The cytokine is a disulfide-linked heterodimer composed of the 35-kD subunit encoded by this gene, and a 40-kD subunit that is a member of the cytokine receptor family. This cytokine is required for the T-cell-independent induction of interferon (IFN)-gamma, and is important for the differentiation of both Th1 and Th2 cells. The responses of lymphocytes to this cytokine are mediated by the activator of transcription protein STAT4. Nitric oxide synthase 2A (NOS2A/NOS2) is found to be required for the signaling process of this cytokine in innate immunity. [provided by RefSeq, Jul 2008]

Research Articles on IL12

Similar Products

Product Notes

The Human IL12 (Catalog #AAA2708676) is a CLIA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2708676 CLIA Kit recognizes Human IL12. AAA Biotech's Interleukin 12 (IL12) can be used in a range of immunoassay formats including, but not limited to, Chemiluminescence Immunoassay (CLIA). Researchers should empirically determine the suitability of the IL12 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Interleukin 12 (IL12), CLIA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.