Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Testing Data (Brain abscesses were induced in mice following the intracerebral inoculation of live Staphylococcus aureus. Animals received intravenous injections of NIR-FLIVO 690 Tracer or NIR-FLIVO 690 Free Dye Control at 17 hours post-infection, whereupon signals were acquired 1 hour later from brain tissues ex vivo using an IVIS Spectrum (Caliper Life Sciences). Strong caspase activity was associated with brain abscesses following administration of the NIR-FLIVO 690 Tracer (right image), whereas minimal signal was detected in animals injected with the NIR-FLIVO 690 Free Dye Control (left image).)

NIR-FLIVO 690 Tracer Assay Kit

NIR-FLIVO 690 Tracer In vivo Assay

Synonyms
NIR-FLIVO 690 Tracer; NIR-FLIVO 690 Tracer In vivo Assay; NIR-FLIVO 690 Tracer assay kit
Ordering
For Research Use Only!
Preparation and Storage
-20 degree C

Testing Data

(Brain abscesses were induced in mice following the intracerebral inoculation of live Staphylococcus aureus. Animals received intravenous injections of NIR-FLIVO 690 Tracer or NIR-FLIVO 690 Free Dye Control at 17 hours post-infection, whereupon signals were acquired 1 hour later from brain tissues ex vivo using an IVIS Spectrum (Caliper Life Sciences). Strong caspase activity was associated with brain abscesses following administration of the NIR-FLIVO 690 Tracer (right image), whereas minimal signal was detected in animals injected with the NIR-FLIVO 690 Free Dye Control (left image).)

Testing Data (Brain abscesses were induced in mice following the intracerebral inoculation of live Staphylococcus aureus. Animals received intravenous injections of NIR-FLIVO 690 Tracer or NIR-FLIVO 690 Free Dye Control at 17 hours post-infection, whereupon signals were acquired 1 hour later from brain tissues ex vivo using an IVIS Spectrum (Caliper Life Sciences). Strong caspase activity was associated with brain abscesses following administration of the NIR-FLIVO 690 Tracer (right image), whereas minimal signal was detected in animals injected with the NIR-FLIVO 690 Free Dye Control (left image).)

Testing Data

(IN VIVO APOPTOSIS IN MOUSE BRAIN. Here are whole animal images using FLIVO to study brain infections. Image take with a Carestream In Vivo FX PRO imager. Adult wild-type Balb/c mice were either given a control (#1&2 top and middle) or intranasal inoculation with the HSV-1 virus (#3 bottom), which is absorbed thru the epithelium and is known to induce apoptosis in the brain. 7 days later, at the peak of infection, the mice were injected IV in the tail vein without any reagent (#1) or with NIR-690 (#2 and #3 middle and bottom), and imaged 4 hours later. We can see strong caspase activity located in the brain of the bottom animal treated with HSV-1 and injected with NIR690 (#3 bottom). Minimal signal was detected in the liver region of both mice injected with NIR690 (#2 and #3) as the liver is the route of clearance for FLIVO tracers. There is no signal in the uninfected control (#1 top), therefore #2 (middle) reveals background staining.)

Testing Data (IN VIVO APOPTOSIS IN MOUSE BRAIN. Here are whole animal images using FLIVO to study brain infections. Image take with a Carestream In Vivo FX PRO imager. Adult wild-type Balb/c mice were either given a control (#1&2 top and middle) or intranasal inoculation with the HSV-1 virus (#3 bottom), which is absorbed thru the epithelium and is known to induce apoptosis in the brain. 7 days later, at the peak of infection, the mice were injected IV in the tail vein without any reagent (#1) or with NIR-690 (#2 and #3 middle and bottom), and imaged 4 hours later. We can see strong caspase activity located in the brain of the bottom animal treated with HSV-1 and injected with NIR690 (#3 bottom). Minimal signal was detected in the liver region of both mice injected with NIR690 (#2 and #3) as the liver is the route of clearance for FLIVO tracers. There is no signal in the uninfected control (#1 top), therefore #2 (middle) reveals background staining.)
Related Product Information for NIR-FLIVO 690 Tracer assay kit
Background/Introduction: FLIVO® (FLuorescence in vIVO) is a powerful method for assessing caspase activity in vivo. Like our FLICA® probes1,2, but optimized for whole live animal imaging, FLIVO Tracers are non-cytotoxic fluorescent inhibitors of caspases. near-infrared (NIR)-FLIVO poly caspase tracers contains the preferred binding sequence for most caspases, Val-Ala-Asp (VAD). This preferred poly caspase tripeptide binding sequence is labeled at the amino terminus end with *Dylight® 690 or 747 NIR label and linked at the carboxyl end to a fluoromethyl ketone (FMK) reactive entity. Apoptosis is an evolutionarily conserved process of programmed cell suicide. It is centered on a cascade of proteolytic enzymes called caspases that are triggered in response to pro-apoptotic signals. Like most other proteases, caspases are synthesized as pro-form precursors that undergo proteolytic maturation, either autocatalytically or in a cascade by enzymes with similar specificity3. Active caspase enzymes consist of two large (~20 kD) and two small (~10 kD) subunits that non-covalently associate to form a two heterodimer, tetrameric active caspase4-6. Once activated, caspases cleave protein substrates leading to the eventual disassembly of the cell. Caspases have been identified in organisms ranging from C. elegans to humans. Mammalian caspases play distinct roles in both apoptosis and inflammation. FLIVO kits provide a simple yet accurate method to detect caspase activity in vivo. To label cells containing elevated levels of active caspases, inject the FLIVO Tracer intravenously and let it circulate. Because the FLIVO Tracer is cell-permeant, it readily diffuses in and out of all cells it encounters as it circulates throughout the body. If there are active caspase enzymes inside a cell, FLIVO will form an irreversible covalent bond with a reactive cysteine on the large subunit of the caspase heterodimer, thereby inhibiting further enzymatic activity. The bound FLIVO Tracer will remain inside the cell if the cell membrane is intact. Any unbound FLIVO is removed from the circulation of the animal in about an hour. The remaining NIR fluorescent signal in the tissue is a direct measure of caspase activity that occurred at the time the reagent was injected. Apoptotic cells will retain a higher concentration of FLIVO Tracer and fluoresce brighter than non-apoptotic cells. There is no interference from pro-caspases or inactive forms of the enzyme. If the treatment is causing cell death via apoptosis, apoptotic cells will have an elevated level of caspase activity relative to non-apoptotic or negative control cells and fluoresce near-infrared with FLIVO. NIR-FLIVO Tracers are used in conjunction with NIR-FLIVO Free Dye Control Assays (sold separately). The NIR-FLIVO Free Dye Control Assay uses the NIR fluorescent dye molecule. When injected, both the Free Dye Control and the Tracer reagents will generate a fluorescent signal, but only the Tracer should bind to active caspases and remain inside an apoptotic cell. The fluorescent signal generated from the Free Dye Control reveals where the fluorescent reagent may have become trapped inside the cell, tissues, or body of the animal without specifically binding with an active caspase. In the context of the overall experiment, this base level of fluorescence is considered background noise compared with the signal generated in animals that were injected with the NIR-FLIVO Tracer. An initial experiment may be necessary to determine when and how much NIR-FLIVO to inject based on the size of the animal, tissue type, experimental conditions, rate of apoptosis, and method of analysis. Generally, the longer FLIVO circulates, the lower the non-specific background signal; however, some apoptotic cells may be lost over time. After 60 minutes, most of the unbound NIR-FLIVO Tracer or Free Dye Control will have cleared the bloodstream. The bound NIR-FLIVO Tracer will remain inside an apoptotic cell and generate a positive signal if the cell membrane is still intact. Once the animals have been injected with FLIVO, they are ready for analysis and no further staining is necessary. Because FLIVO is a direct stain, it eliminates any false positives that may arise from manipulation of the tissue. This gives a true representation of the induction of apoptosis in vivo as a result of the experimental condition. Live animals may be analyzed in a whole animal imager, and /or tissues may be prepared and further analyzed by histological methods. Tissues labeled with FLIVO can be counter-stained with other reagents such as DAPI, and fixed or frozen for future analysis. The fluorescence intensity can be quantified by excising the tissue and analyzing cells with a flow cytometer. NIR-FLIVO 690 Tracer optimally excites at 690 nm and has a peak emission at 709 nm. NIR-FLIVO 747 Tracer optimally excites at 747 nm and has a peak emission at 776 nm.
Product Categories/Family for NIR-FLIVO 690 Tracer assay kit

Similar Products

Product Notes

The NIR-FLIVO 690 Tracer (Catalog #AAA258410) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "NIR-FLIVO 690 Tracer, Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.