Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Mouse anti-Human C3/C3a Monoclonal Antibody | anti-C3/C3a antibody

C3/C3a, Human, mAb 2898

Reactivity
Human
Applications
Western Blot
Synonyms
C3/C3a; Monoclonal Antibody; Human; mAb 2898; Complement protein C3; anti-C3/C3a antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human
Clonality
Monoclonal
Isotype
Mouse IgG1
Form/Format
1 ml (100 ug/ml) 0.2 um filtered antibody solution in PBS, containing 0.1% bovine serum albumin and 0.02% sodium azide.
For unit size 0.5 mg or larger: PBS only (concentration< 0.5mg/ml)
Applicable Applications for anti-C3/C3a antibody
Immunoassay (IA), Western Blot (WB)
Application Notes
Application Notes: W: A reduced sample treatment and SDS-PAGE was used. The band size is ~95 and 8.2 kDa for C3 and C3a respectively (Ref.1).
Application Use: For Western blotting, dilutions to be used depend on detection system applied. It is recommended that users test the reagent and determine their own optimal dilutions. The typical starting working dilution is 1:50.
Immunogen
Peptide CARASHLGLA (last nine amino acids of C3a-desArg)
Positive Control
Human plasma
Preparation and Storage
Product should be stored at 4 degree C. Under recommended storage conditions, product is stable for at least one year. The exact expiry date is indicated on the label.
Related Product Information for anti-C3/C3a antibody
Product Description: The monoclonal antibody 2898 recognizes the C-terminus of human complement protein C3a. The antibody recognizes intact C3, C3a as well as C3a-desArg. C3 is the most abundant protein of the complement system with serum protein levels of about 1.3 mg/ml. The complement system is an important part of the humoral response in innate immunity, consisting of three different pathways. The third complement component, C3, is central to the classical, alternative and lectin pathways of complement activation. Activation products of the complement cascade contain neo-epitopes that are not present in the individual native components. Monoclonal antibodies detecting neo-epitopes have been used for direct quantification of activation at different steps in the complement cascade. The synthesis of C3 is tissue-specific and is modulated in response to a variety of stimulatory agents. An inherited deficiency of C3 predisposes the person to frequent assaults of bacterial infections. In ulcerative colitis, and idiopathic chronic inflammatory bowel disease, the deposition of C3 in the diseased mucosa has been reported. Proteolysis by certain enzymes results in the cleavage of C3 releasing C3a anaphylatoxin and C3b. C3a is a protein of 74 amino acids. C3a itself is very short-lived and in serum is cleaved rapidly into the more stable C3a-desArg (also called acylation stimulating protein, ASP). Therefore, measurement of C3a-desArg allows reliable conclusions about the level of complement activation in the test samples.
C3a is a mediator of local inflammatory processes. It induces smooth muscle contraction, increases vascular permeability, and causes histamine release from mast cells and basophilic leukocytes. C3a is involved in inflammatory reactions seen in gram-negative bacterial sepsis, trauma, ischemic heart disease, post-dialysis syndrome and a variety of autoimmune diseases.
References
1. Hartmann, H et al; Rapid quantification of C3a and C5a using a combination of chromatographic and immunoassay procedures. J Immunol Meth 1993, 166: 35 2. Smalley, D et al; Proteomic discovery of 21 proteins expressed in human plasma-derived but not platelet-derived microparticles. Thromb Haemost 2007, 97: 67

Similar Products

Product Notes

The C3/C3a (Catalog #AAA584432) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The C3/C3a, Human, mAb 2898 reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's C3/C3a can be used in a range of immunoassay formats including, but not limited to, Immunoassay (IA), Western Blot (WB). Application Notes: W: A reduced sample treatment and SDS-PAGE was used. The band size is ~95 and 8.2 kDa for C3 and C3a respectively (Ref.1). Application Use: For Western blotting, dilutions to be used depend on detection system applied. It is recommended that users test the reagent and determine their own optimal dilutions. The typical starting working dilution is 1:50. Researchers should empirically determine the suitability of the C3/C3a for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "C3/C3a, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.