Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Mouse X-Ray Repair Cross Complementing 6 (XRCC6) CLIA Kit | XRCC6 clia kit

Mouse X-Ray Repair Cross Complementing 6 (XRCC6) CLIA Kit

Gene Names
Xrcc6; Ku70; 70kDa; G22p1
Reactivity
Mouse
Applications
Chemiluminescence Immunoassay (CLIA)
Synonyms
X-Ray Repair Cross Complementing 6 (XRCC6); Mouse X-Ray Repair Cross Complementing 6 (XRCC6) CLIA Kit; X-Ray Repair Cross Complementing 6; Ku70; CTC75; CTCBF; G22P1; ML8; TLAA; Lupus Ku Autoantigen Protein P70; ATP-Dependent DNA Helicase 2 Subunit 1; CTC box-binding factor 75 kDa; Thyroid-lupus autoantigen; XRCC6 clia kit
Ordering
For Research Use Only!
Reactivity
Mouse
Specificity
This assay has high sensitivity and excellent specificity for detection of X-Ray Repair Cross Complementing 6 (XRCC6).
No significant cross-reactivity or interference between X-Ray Repair Cross Complementing 6 (XRCC6) and analogues was observed.
Sequence Length
608
Applicable Applications for XRCC6 clia kit
Chemiluminescence Immunoassay (CLIA)
Assay Type
Double-antibody Sandwich
Samples
Tissue homogenates and other biological fluids
Detection Range
13.7-10,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 4.9pg/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level X-Ray Repair Cross Complementing 6 (XRCC6) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level X-Ray Repair Cross Complementing 6 (XRCC6) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Test Principle
The microplate provided in this kit has been pre-coated with an antibody specific to X-Ray Repair Cross Complementing 6 (XRCC6). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to X-Ray Repair Cross Complementing 6 (XRCC6). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the X-Ray Repair Cross Complementing 6 (XRCC6) level in the sample or standard.
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
NCBI Official Full Name
X-ray repair cross-complementing protein 6
NCBI Official Synonym Full Names
X-ray repair complementing defective repair in Chinese hamster cells 6
NCBI Official Symbol
Xrcc6
NCBI Official Synonym Symbols
Ku70; 70kDa; G22p1
NCBI Protein Information
X-ray repair cross-complementing protein 6
UniProt Protein Name
X-ray repair cross-complementing protein 6
UniProt Gene Name
Xrcc6
UniProt Synonym Gene Names
G22p1; Ku70; 5'-dRP/AP lyase Ku70; CTC75; CTCBF; Ku70

Uniprot Description

Single-stranded DNA-dependent ATP-dependent helicase. Has a role in chromosome translocation. The DNA helicase II complex binds preferentially to fork-like ends of double-stranded DNA in a cell cycle-dependent manner. It works in the 3'-5' direction. Binding to DNA may be mediated by XRCC6. Involved in DNA non-homologous end joining (NHEJ) required for double-strand break repair and V(D)J recombination. The XRCC5/6 dimer acts as regulatory subunit of the DNA-dependent protein kinase complex DNA-PK by increasing the affinity of the catalytic subunit PRKDC to DNA by 100-fold. The XRCC5/6 dimer is probably involved in stabilizing broken DNA ends and bringing them together. The assembly of the DNA-PK complex to DNA ends is required for the NHEJ ligation step. Required for osteocalcin gene expression. Probably also acts as a 5'-deoxyribose-5-phosphate lyase (5'-dRP lyase), by catalyzing the beta-elimination of the 5' deoxyribose-5-phosphate at an abasic site near double-strand breaks. 5'-dRP lyase activity allows to 'clean' the termini of abasic sites, a class of nucleotide damage commonly associated with strand breaks, before such broken ends can be joined. The XRCC5/6 dimer together with APEX1 acts as a negative regulator of transcription.

Research Articles on XRCC6

Similar Products

Product Notes

The Mouse XRCC6 xrcc6 (Catalog #AAA2708747) is a CLIA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2708747 CLIA Kit recognizes Mouse XRCC6. AAA Biotech's X-Ray Repair Cross Complementing 6 (XRCC6) can be used in a range of immunoassay formats including, but not limited to, Chemiluminescence Immunoassay (CLIA). Researchers should empirically determine the suitability of the XRCC6 xrcc6 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "X-Ray Repair Cross Complementing 6 (XRCC6), CLIA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.