Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

C1RB sirna

C1RB siRNA (Mouse)

Gene Names
C1rb; mC1rB; Gm8551
Reactivity
Mouse
Applications
RNA Interference (RNAi)
Purity
> 97%
Synonyms
C1RB; C1RB siRNA (Mouse); C1R; Complement C1r-B subcomponent; Complement component 1 subcomponent r-B; C1RB sirna
Ordering
For Research Use Only!
Host
Synthetic
Reactivity
Mouse
Specificity
C1RB siRNA (Mouse) is a target-specific 19-23 nt siRNA oligo duplexes designed to knock down gene expression.
Purity/Purification
> 97%
Form/Format
Lyophilized powder
Sequence Length
706
Applicable Applications for C1RB sirna
RNA Interference (RNAi)
Quality Control
Oligonucleotide synthesis is monitored base by base through trityl analysis to ensure appropriate coupling efficiency. The oligo is subsequently purified by affinity-solid phase extraction. The annealed RNA duplex is further analyzed by mass spectrometry to verify the exact composition of the duplex. Each lot is compared to the previous lot by mass spectrometry to ensure maximum lot-to-lot consistency.
Directions for Use
We recommends transfection with 100 nM siRNA 48 to 72 hours prior to cell lysis. Before resuspending, briefly centrifuge the tube to ensure the lyophilized siRNA is at the bottom of the tube. Resuspend the siRNA oligos to an appropriate concentration with DEPC water. For each vial, suitable for 250 transfections in 24 well plate (20 pmol for each well).
Components
We offer pre-designed sets of 3 different target-specific siRNA oligo duplexes of mouse C1RB gene. Each vial contains 5 nmol of lyophilized siRNA. The duplexes can be transfected individually or pooled together to achieve knockdown of the target gene, which is most commonly assessed by qPCR or western blot. Our siRNA oligos are also chemically modified (2'-OMe) at no extra charge for increased stability and enhanced knockdown in vitro and in vivo.
Preparation and Storage
Shipped at 4 degree C. Store at -20 degree C for one year.
Related Product Information for C1RB sirna
siRNA to inhibit C1RB expression using RNA interference

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
79,936 Da
NCBI Official Full Name
complement C1r-B subcomponent
NCBI Official Synonym Full Names
complement component 1, r subcomponent B
NCBI Official Symbol
C1rb
NCBI Official Synonym Symbols
mC1rB; Gm8551
NCBI Protein Information
complement C1r-B subcomponent
UniProt Protein Name
Complement C1r-B subcomponent
UniProt Gene Name
C1rb
UniProt Synonym Gene Names
C1r
UniProt Entry Name
C1RB_MOUSE

Uniprot Description

C1RB: C1r B chain is a serine protease that combines with C1q and C1s to form C1, the first component of the classical pathway of the complement system. C1 is a calcium-dependent trimolecular complex of C1q, C1r and C1s in the molar ration of 1:2:2. C1r is a dimer of identical chains, each of which is activated by cleavage into two chains, A and B, connected by disulfide bonds. Belongs to the peptidase S1 family.

Protein type: EC 3.4.21.41

Cellular Component: extracellular region

Molecular Function: peptidase activity; hydrolase activity; serine-type peptidase activity; serine-type endopeptidase activity; calcium ion binding; catalytic activity

Biological Process: immune system process; innate immune response; proteolysis; complement activation, classical pathway; complement activation

Similar Products

Product Notes

The C1RB c1rb (Catalog #AAA8221491) is a siRNA produced from Synthetic and is intended for research purposes only. The product is available for immediate purchase. The C1RB siRNA (Mouse) reacts with Mouse and may cross-react with other species as described in the data sheet. AAA Biotech's C1RB can be used in a range of immunoassay formats including, but not limited to, RNA Interference (RNAi). Researchers should empirically determine the suitability of the C1RB c1rb for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "C1RB, siRNA" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.