Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Flow Cytometry (FC/FACS) (Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood).)

Mouse anti-Human CD95 Antibody | anti-CD95 antibody

Anti-Hu CD95 PE-DyLight 594

Reactivity
Human
Applications
Flow Cytometry, Functional Assay
Purity
Purified antibody is conjugated with activated tandem dye of R-phycoerythrin-DyLight594 (PE-DyLight594) under optimum conditions and unconjugated antibody and free fluorochrome are removed by size-exclusion chromatography.
Synonyms
CD95; Anti-Hu CD95 PE-DyLight 594; FAS1; APT1; APO-1; FASTM; ALPS1A; TNFRSF6; Fas cell surface death receptor; anti-CD95 antibody
Ordering
For Research Use Only!
Host
Mouse
Reactivity
Human
Isotype
Mouse IgG1
Clone Number
LT95
Specificity
The antibody LT95 reacts with an extracellular epitope on CD95 (Fas/APO-1), a 46kDa single chain type I glycoprotein of the tumour necrosis factor/nerve growth factor (TNF/NGF) receptor superfamily, expressed on a variety of normal and neoplastic cells. It seems that the antibody LT95 does not induce Fas mediated apoptosis, although it cross-blocks anti-Fas DX2 antibody that recognizes a functional epitope of Fas molecule.
Purity/Purification
Purified antibody is conjugated with activated tandem dye of R-phycoerythrin-DyLight594 (PE-DyLight594) under optimum conditions and unconjugated antibody and free fluorochrome are removed by size-exclusion chromatography.
Form/Format
Stabilizing phosphate buffered saline (PBS), pH7.4, 15mM sodium azide
Applicable Applications for anti-CD95 antibody
Flow Cytometry (FC/FACS)(QC tested)
Application Notes
FC/FACS: The reagent is designed for analysis of human blood cells using 4ul reagent/100ul of whole blood or 106 cells in a suspension. The content of a vial (0.4ml) is sufficient for 100 tests.
Conjugation
PE-DyLight 594
Immunogen
HUT-78 human T cell lymphoma cell line
Excitation Laser
blue (488 nm)
Preparation and Storage
Store at 2-8 degree C. Protect from prolonged exposure to light. Do not freeze.

Flow Cytometry (FC/FACS)

(Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood).)

Flow Cytometry (FC/FACS) (Flow cytometry surface staining pattern of human peripheral whole blood stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood).)

Flow Cytometry (FC/FACS)

(Flow cytometry multicolor surface staining of human lymphocytes stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood) and anti-human CD3 (UCHT1) APC antibody (10ul reagent/100ul of peripheral whole blood).)

Flow Cytometry (FC/FACS) (Flow cytometry multicolor surface staining of human lymphocytes stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood) and anti-human CD3 (UCHT1) APC antibody (10ul reagent/100ul of peripheral whole blood).)

Flow Cytometry (FC/FACS)

(Separation of human CD95 positive T cells (red-filled) from CD95 negative lymphocytes (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood).)

Flow Cytometry (FC/FACS) (Separation of human CD95 positive T cells (red-filled) from CD95 negative lymphocytes (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using anti-human CD95 (LT95) PE-DyLight 594 antibody (4ul reagent/100ul of peripheral whole blood).)
Related Product Information for anti-CD95 antibody
CD95 (Fas, APO-1), a 46kDa transmembrane glycoprotein, is a cell death receptor of the TNFR superfamily. Stimulation of CD95 results in aggregation of its intracellular death domains, formation of the death-inducing signaling complex (DISC) and activation of caspases. In type I cells caspase 3 is activated by high amounts of caspase 8 generated at the DISC, in type II cells low concentration of caspase 8 activates pathway leading to the release of cytochrome c from mitochondria and activation of caspase 3 by cytochom c. Besides its roles in induction of apoptosis, Fas also triggers pro-inflammatory cytokine responses.
References
Drosopoulos KG, Robertsml, Cermak L, Sasazuki T, Shirasawa S, Andera L, Pintzas A.: Transformation by oncogenic RAS sensitizes human colon cells to TRAIL-induced apoptosis by up-regulating death receptor 4 and death receptor 5 through a MEK-dependent pathway. J Biol Chem. 2005 Jun 17;280(24):22856-67. Epub 2005 Mar 8., URL: https://www.ncbi.nlm.nih.gov/pubmed/15757891?dopt=
Brumatti G, Yon M, Castro FA, Bueno-da-Silva AE, Jacysyn JF, Brunner T, Amarante-Mendes GP: Conversion of CD95 (Fas) Type II into Type I signaling by sub-lethal doses of cycloheximide. Exp Cell Res. 2008 Feb 1;314(3):554-63., URL: https://www.ncbi.nlm.nih.gov/pubmed/18078929?ordin
Guo Z, Zhang M, Tang H, Cao X: Fas signal links innate and adaptive immunity by promoting dendritic-cell secretion of CC and CXC chemokines. Blood. 2005 Sep 15;106(6):2033-41., URL: https://www.ncbi.nlm.nih.gov/pubmed/15941911?ordin
Park DR, Thomsen AR, Frevert CW, Pham U, Skerrett SJ, Kiener PA, Liles WC: Fas (CD95) induces proinflammatory cytokine responses by human monocytes and monocyte-derived macrophages. J Immunol. 2003 Jun 15;170(12):6209-16., URL: https://www.ncbi.nlm.nih.gov/pubmed/12794152?ordin
Scaffidi C, Fulda S, Srinivasan A, Friesen C, Li F, Tomaselli KJ, Debatin KM, Krammer PH, Peter ME: Two CD95 (APO-1/Fas) signaling pathways. EMBO J. 1998 Mar 16;17(6):1675-87., URL: https://www.ncbi.nlm.nih.gov/pubmed/9501089?ordina

Similar Products

Product Notes

The CD95 (Catalog #AAA1802275) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. The Anti-Hu CD95 PE-DyLight 594 reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's CD95 can be used in a range of immunoassay formats including, but not limited to, Flow Cytometry (FC/FACS)(QC tested). FC/FACS: The reagent is designed for analysis of human blood cells using 4ul reagent/100ul of whole blood or 106 cells in a suspension. The content of a vial (0.4ml) is sufficient for 100 tests. Researchers should empirically determine the suitability of the CD95 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "CD95, Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.