Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Mouse Troponin T Type 2, Cardiac (TNNT2) ELISA Kit | TNNT2 elisa kit

Mouse Troponin T Type 2, Cardiac (TNNT2) Mini Samples ELISA Kit

Gene Names
TNNT2; CMH2; RCM3; TnTC; cTnT; CMD1D; CMPD2; LVNC6
Reactivity
Mouse
Applications
ELISA
Synonyms
Troponin T Type 2; Cardiac (TNNT2); Mouse Troponin T Type 2; Cardiac (TNNT2) Mini Samples ELISA Kit; Cardiac; CMH2; cTnT; TnTc; Cardiomyopathy; Hypertrophic 2; Cardiac muscle troponin T; TNNT2 elisa kit
Ordering
For Research Use Only!
Reactivity
Mouse
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Troponin T Type 2, Cardiac (TNNT2).
No significant cross-reactivity or interference between Mini Samples Troponin T Type 2, Cardiac (TNNT2) and analogues was observed.
Sequence Length
285
Applicable Applications for TNNT2 elisa kit
ELISA (EIA)
Assay Type
Double-antibody Sandwich
Samples
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
15.6-1,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 5.5pg/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Troponin T Type 2, Cardiac (TNNT2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Troponin T Type 2, Cardiac (TNNT2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Test Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Troponin T Type 2, Cardiac (TNNT2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Troponin T Type 2, Cardiac (TNNT2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Troponin T Type 2, Cardiac (TNNT2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Mini Samples Troponin T Type 2, Cardiac (TNNT2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Official Full Name
Troponin T type 2 (cardiac)
NCBI Official Synonym Full Names
troponin T2, cardiac type
NCBI Official Symbol
TNNT2
NCBI Official Synonym Symbols
CMH2; RCM3; TnTC; cTnT; CMD1D; CMPD2; LVNC6
NCBI Protein Information
troponin T, cardiac muscle
Protein Family

NCBI Description

The protein encoded by this gene is the tropomyosin-binding subunit of the troponin complex, which is located on the thin filament of striated muscles and regulates muscle contraction in response to alterations in intracellular calcium ion concentration. Mutations in this gene have been associated with familial hypertrophic cardiomyopathy as well as with dilated cardiomyopathy. Transcripts for this gene undergo alternative splicing that results in many tissue-specific isoforms, however, the full-length nature of some of these variants has not yet been determined. [provided by RefSeq, Jul 2008]

Research Articles on TNNT2

Similar Products

Product Notes

The Mouse TNNT2 (Catalog #AAA2708409) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2708409 ELISA Kit recognizes Mouse TNNT2. AAA Biotech's Troponin T Type 2, Cardiac (TNNT2) can be used in a range of immunoassay formats including, but not limited to, ELISA (EIA). Researchers should empirically determine the suitability of the TNNT2 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Troponin T Type 2, Cardiac (TNNT2), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.