Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Mouse Zika Virus Nonstructural Protein (NS1) Monoclonal Antibody | anti-NS1 antibody

Monoclonal Antibody to Zika Virus Nonstructural Protein (NS1)

Applications
ELISA, Functional Assay, Immunofluorescence, Lateral Flow
Purity
> 90% pure (SDS-PAGE). Protein A Chromatography
Synonyms
Zika Virus Nonstructural Protein (NS1); Monoclonal Antibody; Monoclonal Antibody to Zika Virus Nonstructural Protein (NS1); MAb to Zika Virus NS1; Zika Virus NS1; anti-NS1 antibody
Ordering
For Research Use Only!
Host
Mouse
Clonality
Monoclonal
Isotype
IgG1
Specificity
Reacts with Zika Virus NS1.
Does not cross react with Dengue 1-4, Tick-Borne Encephalitis Virus, West Nile Virus, Yellow Fever Virus, Japanese Encephalitis Virus and Chikungunya Virus by IFA.
Purity/Purification
> 90% pure (SDS-PAGE). Protein A Chromatography
Form/Format
Purified, Liquid
Concentration
2.8 mg/mL (OD80 nm, E 01% =1.3 (varies by lot)
Applicable Applications for anti-NS1 antibody
Suitable for use in ELISA (EIA), Lateral Flow and IFA. Each laboratory should determined an optimum working titer for use in its particular application. Other applications have not been tested but use in such assays should not necessarily be excluded.
Application Notes
Recommended pairs for sandwich ELISA:
Capture: MBS313394; Detection: MBS313395
Capture: MBS313394; Detection: MBS313396
Source
Ascites
Immunogen
Zika Virus Full Length Recombinant
Buffer
0.01 M Phosphate Buffered Saline, pH 7.2
Preservative
0.1% Sodium Azide
Preparation and Storage
Store at 2-8°C.
Related Product Information for anti-NS1 antibody
MAb to Zika Virus NS1
Monoclonal Antibody to Zika Virus Nonstructural Protein (NS1)
Product Categories/Family for anti-NS1 antibody

Similar Products

Product Notes

The NS1 (Catalog #AAA313394) is an Antibody produced from Mouse and is intended for research purposes only. The product is available for immediate purchase. AAA Biotech's Zika Virus Nonstructural Protein (NS1) can be used in a range of immunoassay formats including, but not limited to, Suitable for use in ELISA (EIA), Lateral Flow and IFA. Each laboratory should determined an optimum working titer for use in its particular application. Other applications have not been tested but use in such assays should not necessarily be excluded. Recommended pairs for sandwich ELISA: Capture: MBS313394; Detection: MBS313395 Capture: MBS313394; Detection: MBS313396. Researchers should empirically determine the suitability of the NS1 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Zika Virus Nonstructural Protein (NS1), Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.