Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Amplification (Synthesized standard amplifiction curve (10nM/100pM))

Human hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p PCR Kit

hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p Calibration Kit

Reactivity
Human
Applications
Real-time RT-PCR
Synonyms
hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p; hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p Calibration Kit; hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p pcr kit
Ordering
For Research Use Only!
Reactivity
Human
Applicable Applications for hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p pcr kit
Real-time RT-PCR
Application Notes
The Real-Time RT-PCR detection and cel-mir-39-3p calibration Kit contains the whole reagent including the stem-loop RT primer & specific PCR primer set for microRNA quantificaion and cel-mir-39-3p primer set for calibration. It provides a sensitive and specific method of real-time PCR for relative quantificating of miRNAs from total RNA samples. It is Ideal for validating microRNA expression profiling data and high-throughput applications. Trait lies in even highly homogized miRNAs can be accurately dicriminated ensurenced by stemloop RT primer and high specific miRNAs primer set.
Samples
For the detection and quantification of miRNAs hsa-mir-320a normalized by cel-mir-39-3p using Real-time RT-PCR detection instruments.
Dry Ice Shipment
Extra charge fee may add to your shipping cost as dry ice is required to ship this product.
Preparation and Storage
Shipped at 4 degree C. Store at -20 degree C for 6 months.

Amplification

(Synthesized standard amplifiction curve (10nM/100pM))

Amplification (Synthesized standard amplifiction curve (10nM/100pM))

Amplification

(Amplifiction curve in total RNA from cells)

Amplification (Amplifiction curve in total RNA from cells)

Dissociation Curve

(Dissociation curve (Note: the minor peak on the left is the negative control))

Dissociation Curve (Dissociation curve (Note: the minor peak on the left is the negative control))

Electrophoresis

(Electrophoresis Image (20bp marker))

Electrophoresis (Electrophoresis Image (20bp marker))
Related Product Information for hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p pcr kit
Principle of the Assay||MiRNAs real-time Quantitation assay of miRNAs includes two steps, stem-loop RT and real-time PCR. Stem-loop RT primers bind to at the 3' portion of miRNA molecules and are reverse transcribed with reverse transcriptase. Then, the RT product is quantified using real-time PCR that includes miRNA-specific forward primer, reverse primer and SYBR Green dye.

Background/Introduction: The miRNAs RT-PCR Quantitation Kit is a sensitive and specific method using real-time PCR for the detection and quantification of miRNAs (miRNA) from total RNA samples. miRNAs are small, single-stranded, ~19 - 23 nt RNA molecules encoded in the genomes of plants, animals, and viruses. Mature miRNAs enter the RNA-induced silencing complex (RISC) and guide the RISC to induce translational repression or endonucleolytic cleavage of specific target mRNAs. Unlike commonly used methods for detection of miRNAs, the miRNAs qPCR Quantitation Kit is more rapid and sensitive. This kit contains miRNA hsa-mir-320a and cel-mir-39-3p high specific RT and PCR primer set, with SYBR Green dye included. The stem-loop like miRNAs RT primer and the miRNAs high specific primer set ensure the RT and PCR reaction would not be interfered by the miRNAs precursors. The reaction template could be total RNA or cell lysates. The system enables highly sensitive detection from as few as 10 copies of a target miRNAs, with a broad dynamic range that supports accurate quantification of high-copy mRNA from up to 1 ug of total RNA. High specificity ensurenced by stemloop RT primer and high specific miRNAs primer set; even highly homogized miRNAs can be accurately dicriminated. Higher dynamic range and sensitivity of miRNAs quantification than conventional method (such as Northern blot & micro-array) with broad dynamic range of at least seven orders of magnitude, and in this ready to use formulation can quantify as few as 7 copies of a miRNA target in as little as 0.1 pg of total RNA. Less sample requirement Total RNA, cell lysate or purified samll RNA can work as the qPCR Quantitation Kit's template, even the genomic DNA contamination would not interfere in miRNAs quantification. miRNA synthetic standard can work as a standard curve when you need to know the absolute number of a miRNA in one cell or work as positive control when you need to know the relative expression ratio between miRNA and cel-mir-39-3p or 5S rRNA.

Similar Products

Product Notes

The Human hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p (Catalog #AAA8244875) is a PCR Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA8244875 PCR Kit recognizes Human hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p. AAA Biotech's hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p can be used in a range of immunoassay formats including, but not limited to, Real-time RT-PCR. The Real-Time RT-PCR detection and cel-mir-39-3p calibration Kit contains the whole reagent including the stem-loop RT primer & specific PCR primer set for microRNA quantificaion and cel-mir-39-3p primer set for calibration. It provides a sensitive and specific method of real-time PCR for relative quantificating of miRNAs from total RNA samples. It is Ideal for validating microRNA expression profiling data and high-throughput applications. Trait lies in even highly homogized miRNAs can be accurately dicriminated ensurenced by stemloop RT primer and high specific miRNAs primer set. Researchers should empirically determine the suitability of the hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "hsa-mir-320a Real-Time RT-PCR Detection and cel-mir-39-3p, PCR Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.