Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only)

Human Stromal cell derived factor 1a, SDF-1a ELISA Kit | SDF-1a elisa kit

Human Stromal cell derived factor 1a, SDF-1a ELISA Kit

Gene Names
CXCL12; IRH; PBSF; SDF1; TLSF; TPAR1; SCYB12
Reactivity
Human
Synonyms
Stromal cell derived factor 1a; SDF-1a; Human Stromal cell derived factor 1a; SDF-1a ELISA Kit; SDF-1a elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Sequence Length
89
Samples
Serum, plasma, cell culture supernates, cell lysates, tissue homogenates
Assay Type
Quantitative Sandwich
Detection Range
5ng/L - 1500ng/L
Sensitivity
2.52ng/L
Intra-Assay
CV<8%
Inter-Assay
CV<10%
Preparation and Storage
Store at 2 to 8 degree C for 6 months.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for SDF-1a elisa kit
Intended Uses: This sandwich kit is for the accurate quantitative detection of human Stromal Cell Derived Factor 1A (also known as SDF-1A) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

Principles of the Assay: This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with human SDF-1A antibody. SDF-1A present in the sample is added and binds to antibodies coated on the wells. And then biotinylated human SDF-1A Antibody is added and binds to SDF-1A in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated SDF-1A antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of human SDF-1A. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
Molecular Weight
10,103 Da
NCBI Official Full Name
stromal cell-derived factor 1a
NCBI Official Synonym Full Names
C-X-C motif chemokine ligand 12
NCBI Official Symbol
CXCL12
NCBI Official Synonym Symbols
IRH; PBSF; SDF1; TLSF; TPAR1; SCYB12
NCBI Protein Information
stromal cell-derived factor 1
UniProt Protein Name
Stromal cell-derived factor 1
UniProt Gene Name
CXCL12
UniProt Synonym Gene Names
SDF1; SDF1A; SDF1B; SDF-1; hSDF-1; IRH; hIRH; PBSF

NCBI Description

This antimicrobial gene encodes a stromal cell-derived alpha chemokine member of the intercrine family. The encoded protein functions as the ligand for the G-protein coupled receptor, chemokine (C-X-C motif) receptor 4, and plays a role in many diverse cellular functions, including embryogenesis, immune surveillance, inflammation response, tissue homeostasis, and tumor growth and metastasis. Mutations in this gene are associated with resistance to human immunodeficiency virus type 1 infections. Multiple transcript variants encoding different isoforms have been found for this gene. [provided by RefSeq, Sep 2014]

Uniprot Description

Chemoattractant active on T-lymphocytes and monocytes but not neutrophils. Activates the C-X-C chemokine receptor CXCR4 to induce a rapid and transient rise in the level of intracellular calcium ions and chemotaxis. SDF-1-beta(3-72) and SDF-1-alpha(3-67) show a reduced chemotactic activity. Binding to cell surface proteoglycans seems to inhibit formation of SDF-1-alpha(3-67) and thus to preserve activity on local sites. Also binds to atypical chemokine receptor ACKR3, which activates the beta-arrestin pathway and acts as a scavenger receptor for SDF-1. Binds to the allosteric site (site 2) of integrins and activates integrins ITGAV:ITGB3, ITGA4:ITGB1 and ITGA5:ITGB1 in a CXCR4-independent manner (PubMed:29301984). Acts as a positive regulator of monocyte migration and a negative regulator of monocyte adhesion via the LYN kinase. Stimulates migration of monocytes and T-lymphocytes through its receptors, CXCR4 and ACKR3, and decreases monocyte adherence to surfaces coated with ICAM-1, a ligand for beta-2 integrins. SDF1A/CXCR4 signaling axis inhibits beta-2 integrin LFA-1 mediated adhesion of monocytes to ICAM-1 through LYN kinase. Inhibits CXCR4-mediated infection by T-cell line-adapted HIV-1. Plays a protective role after myocardial infarction. Induces down-regulation and internalization of ACKR3 expressed in various cells. Has several critical functions during embryonic development; required for B-cell lymphopoiesis, myelopoiesis in bone marrow and heart ventricular septum formation. Stimulates the proliferation of bone marrow-derived B-cell progenitors in the presence of IL7 as well as growth of stromal cell-dependent pre-B-cells ().

Research Articles on SDF-1a

Similar Products

Product Notes

The Human SDF-1a cxcl12 (Catalog #AAA162110) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA162110 ELISA Kit recognizes Human SDF-1a. It is sometimes possible for the material contained within the vial of "Stromal cell derived factor 1a, SDF-1a, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.