Human Matrix Metalloproteinase 17 (MMP17) ELISA Kit | MMP17 elisa kit

Human Matrix Metalloproteinase 17 (MMP17) ELISA Kit

Gene Names
MMP17; MT4-MMP
Reactivity
Human
Synonyms
Matrix Metalloproteinase 17 (MMP17); Human Matrix Metalloproteinase 17 (MMP17) ELISA Kit; MT4-MMP; MMP4; Membrane-type matrix metalloproteinase 4; Membrane-type-4 matrix metalloproteinase; MMP17 elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 17 (MMP17).
No significant cross-reactivity or interference between Matrix Metalloproteinase 17 (MMP17) and analogues was observed.
Sequence Length
603
Assay Type
Double-antibody Sandwich
Samples
Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and Other Biological Fluids
Detection Range
0.156-10ng/mL
Sensitivity
< 0.064ng/mL
Application
Enzyme-linked immunosorbent assay for Antigen Detection.
Intra-assay Precision (Precision within an assay)
3 samples with low, middle and high level Matrix Metalloproteinase 17 (MMP17) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays)
3 samples with low, middle and high level Matrix Metalloproteinase 17 (MMP17) were tested on 3 different plates, 8 replicates in each plate.
CV(%) =
SD/meanX100
Intra-Assay
CV<10%
Inter-Assay
CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Typical Testing Data/Standard Curve (for reference only)

Typical Testing Data/Standard Curve (for reference only)
Related Product Information for MMP17 elisa kit
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Matrix Metalloproteinase 17 (MMP17). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Matrix Metalloproteinase 17 (MMP17). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Matrix Metalloproteinase 17 (MMP17), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Matrix Metalloproteinase 17 (MMP17) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
Molecular Weight
57,938 Da
NCBI Official Full Name
matrix metalloproteinase-17 preproprotein
NCBI Official Synonym Full Names
matrix metallopeptidase 17 (membrane-inserted)
NCBI Official Symbol
MMP17
NCBI Official Synonym Symbols
MT4-MMP
NCBI Protein Information
matrix metalloproteinase-17
UniProt Protein Name
Matrix metalloproteinase-17
Protein Family
UniProt Gene Name
MMP17
UniProt Synonym Gene Names
MT4MMP; MMP-17; MT-MMP 4; MTMMP4; MT4-MMP; MT4MMP
UniProt Entry Name
MMP17_HUMAN

NCBI Description

Proteins of the matrix metalloproteinase (MMP) family are involved in the breakdown of extracellular matrix in normal physiological processes, such as embryonic development, reproduction, and tissue remodeling, as well as in disease processes, such as arthritis and metastasis. Most MMP's are secreted as inactive proproteins which are activated when cleaved by extracellular proteinases. The protein encoded by this gene is considered a member of the membrane-type MMP (MT-MMP) subfamily. However, this protein is unique among the MT-MMP's in that it is a GPI-anchored protein rather than a transmembrane protein. The protein activates MMP-2 by cleavage. [provided by RefSeq, Jul 2008]

Uniprot Description

MMP17: Endopeptidase that degrades various components of the extracellular matrix, such as fibrin. May be involved in the activation of membrane-bound precursors of growth factors or inflammatory mediators, such as tumor necrosis factor-alpha. May also be involved in tumoral process. Not obvious if able to proteolytically activate progelatinase A. Does not hydrolyze collagen types I, II, III, IV and V, gelatin, fibronectin, laminin, decorin nor alpha1-antitrypsin. Belongs to the peptidase M10A family. 2 isoforms of the human protein are produced by alternative splicing.

Protein type: Activator; Membrane protein, GPI anchor; Membrane protein, integral; EC 3.4.24.-; Protease

Chromosomal Location of Human Ortholog: 12q24.3

Cellular Component: proteinaceous extracellular matrix; integral to plasma membrane

Molecular Function: zinc ion binding; metalloendopeptidase activity; enzyme activator activity; calcium ion binding

Biological Process: positive regulation of catalytic activity; proteolysis

Research Articles on MMP17

Similar Products

Product Notes

The Human MMP17 mmp17 (Catalog #AAA2000010) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA2000010 ELISA Kit recognizes Human MMP17. It is sometimes possible for the material contained within the vial of "Matrix Metalloproteinase 17 (MMP17), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.