Loading...

Skip to main content

Call us on + 1 (800) 604-9114 for more information about our products

Looking for specific datasheet Manual/COA/MSDS?
Request a Manual/COA/MSDS

Interested to get a quote about our products?
Request a Quote

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Anti-epidemic hemorrhagic fever virus antibody (IgG) Standard Curve.)

Human Epidemic Hemorrhagic Fever Virus (IgG) ELISA Kit | IgG elisa kit

Human Anti-Epidemic Hemorrhagic Fever Virus Antibody (IgG) ELISA Kit

Reactivity
Human
Synonyms
Epidemic Hemorrhagic Fever Virus (IgG); Human Anti-Epidemic Hemorrhagic Fever Virus Antibody (IgG) ELISA Kit; IgG elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
Human Anti-epidemic hemorrhagic fever virus antibody (IgG) ELISA Kit has high sensitivity and excellent specificity for detection of Human IgG. No significant cross-reactivity or interference between Human IgG and analogues was observed.
Assay Type
Sandwich ELISA (Quantitative)
Samples
Cell Culture Supernatants, Serum, Plasma, Other Biological Fluids
Detection Method
Colorimetric
Usage Notes
* Do not mix components from different kit lots or use reagents beyond the kit expiration date.
* Allow all reagents to warm to room temperature for at least 30 minutes before opening.
* Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
* Unused wells must be kept desiccated at 4 degree C in the sealed bag provided.
* Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
* It is recommended that all samples and standards be assayed in duplicate or triplicate.
Preparation and Storage
Store at 2-8 degree C.

Typical Testing Data/Standard Curve (for reference only)

(Fig.1. Human Anti-epidemic hemorrhagic fever virus antibody (IgG) Standard Curve.)

Typical Testing Data/Standard Curve (for reference only) (Fig.1. Human Anti-epidemic hemorrhagic fever virus antibody (IgG) Standard Curve.)
Related Product Information for IgG elisa kit
Description: This Human Anti-epidemic hemorrhagic fever virus antibody (IgG) ELISA Kit employs the competitive enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with an antibody specific to IgG. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated IgG and incubated. The competitive inhibition reaction is launched between with HRP labeled IgG and unlabeled IgG with the antibody. A substrate solution is added to the wells and the color develops in opposite to the amount of IgG in the sample. The color development is stopped and the intensity of the color is measured.

Background: Immunoglobulin G (IgG) is a monomeric immunoglobulin, built of two heavy chains gamma and two light chains. Each IgG has two antigen binding sites. It is the most abundant immunoglobulin and is approximately equally distributed in blood and in tissue liquids, constituting 75% of serum immunoglobulins in humans. IgG molecules are synthesised and secreted by plasma B cells. IgG antibodies are predominately involved in the secondary antibody response, which occurs approximately one month following antigen recognition, thus the presence of specific IgG generally corresponds to maturation of the antibody response. This is the only isotype that can pass through the human placenta, thereby providing protection to the fetus in utero. Along with IgA secreted in the breast milk, residual IgG absorbed through the placenta provides the neonate with humoral immunity before its own immune system develops.

Similar Products

Product Notes

The Human IgG (Catalog #AAA9716124) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA9716124 ELISA Kit recognizes Human IgG. It is sometimes possible for the material contained within the vial of "Epidemic Hemorrhagic Fever Virus (IgG), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Looking for a specific manual?
Request a Manual

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.